Loading…

Variable Name: TIC_OverflowValue_2

Variable ID: 0x41F6

Variable Label: Totalizer overflow 2

Variable Help: Displays the current totalizer overflow. Additional information: If the current totalizer counter exceeds the operating tool's maximum numerical display range of 7 digits, the amount above this range is expressed as an overflow. The current totalizer counter therefore equals the sum of the overflow and the totalizer value displayed in the "Totalizer value @1" parameter. Example of how to calculate the current totalizer counter when the value exceeds the 7 digit display limit of the operating tool: - Value of "Totalizer value @1" parameter: 1,968,457 m³ - Value of "Totalizer overflow @1" parameter: 1 × 10^7 m³ = 10,000,000 m³ - Current totalizer reading: 11,968,457 m³

Variable Handling: R

Variable Class: Dynamic

Variable Size: 4

Variable DataType: Float

Variable Display Format: |en|.0f

Variable Edit Format:

Variable Unit:

Variable Max:

Variable Min:

Variable Read Command List

Command Number Command ID Command Name
194 42E9 read_index_parameter_194

Variable Write Command List

Command Number Command ID Command Name
195 42E7 write_index_parameter_195