Loading…
Loading…
Variable Name: SPV_CurrentEventCategory_1
Variable ID: 0x41B2
Variable Label: Status signal
Variable Help: Indicates the current device status. Additional information: The F, C, S and M status signals are categorized in accordance with VDI/VDE 2650 and NAMUR Recommendation NE 107.
Variable Handling: R
Variable Class: Device
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | OK |
0x0001 | Failure (F) |
0x0002 | Function check (C) |
0x0008 | Out of specification (S) |
0x0004 | Maintenance required (M) |
0x0010 | --- |
0x0020 | No effect (N) |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
173 | 42E8 | read_index_parameter_173 |
Variable Write Command List
None