Variable Name: device_specific_status_0

Variable ID: 0x102B

Variable Label: Status Group 0

Variable Help: Field Device Specific Status Byte 1- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0002 F282 Data storage Remedy information 1. Restart device 2. Contact service
0x0004 F283 Memory content Remedy information 1. Transfer data or reset device 2. Contact service
0x0008 C411 Up-/download active Remedy information Up-/download active, please wait
0x0010 C431 Trim X Remedy information Carry out trim
0x0040 C491 Current output X simulation Remedy information Deactivate simulation

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List

None