Loading…

Variable Name: xmtr_specific_status_0

Variable ID: 0x0FB5

Variable Label: Status do grupo 1

Variable Help: Byte 1 do status do dispositivo de campo- Dado que tem a informação do status do dispositivo de campo relacionado à: falhas / alertas / processo do status.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001
0x0002 A165 electronics defect
0x0004 A531 sensor electronics defect
0x0008 A111 electronics defect
0x0010 A113 electronics defect
0x0020 A114 electronics defect
0x0040 A102 checksum error general reset & new calibr.required
0x0080 A121 electronics defect

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 0FCE read_additional_transmitter_status

Variable Write Command List

None