Variable Name: HO_QVSelector_1
Variable ID: 0x4063
Variable Label: Assign QV
Variable Help: Assign measured variable to the fourth dynamic variable (QV). This value can only be output via the HART interface.
Variable Handling: R/W
Variable Class: HART
Variable Size: 2
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x045F | Pressure |
0x0BD7 | Scaled variable |
0x81A7 | Sensor temperature |
0x0D57 | Sensor pressure |
0x8075 | Electronic temperature |
0x0692 | Percent of range |
0x0693 | Loop current |
0x80E4 | Not used |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
173 | 4324 | read_index_parameter_173 |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
178 | 4322 | write_index_parameter_178 |