Loading…

Variable Name: vAnalogOutputPlausibility

Variable ID: 0x4096

Variable Label: Analog Output Plausibility

Variable Help:

Variable Handling: R/W

Variable Class: Diagnostic

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 t2 greater than t1
0x0002 t1 too long
0x0004 time (t1 or t2) too short
0x0008 warning current too high
0x0010 warning current too low
0x0020 maintenance current too high
0x0040 maintenance current too low

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

None

Variable Write Command List

None