Loading…

Variable Name: SpecFlowPressure

Variable ID: 0x4041

Variable Label: Fixed pressure

Variable Help: Specifies (fixes) the flow-condition pressure when the 'EnablePressureInput' data point is set to "Fixed".

Variable Handling: R/W

Variable Class:

Variable Size: 4

Variable DataType: Float

Variable Display Format: |en|.2f

Variable Edit Format: |en|.2f

Variable Unit:

Variable Max:

Variable Min:

Variable Read Command List

Command Number Command ID Command Name
133 40BD ReadFlowPressureConfiguration

Variable Write Command List

Command Number Command ID Command Name
132 40BC WriteFlowPressureConfiguration