Variable Name: InputPressureUnit
Variable ID: 0x4042
Variable Label: Gage or absolute pressure
Variable Help: Specifies whether the input pressure is absolute (TRUE) or gage (FALSE). If the input pressure is gage, then the absolute pressure is calculated as the sum of the input gage pressure and the atmospheric pressure (specified via the 'AtmosphericPress' data point).
Variable Handling: R/W
Variable Class:
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | Gage |
0x0001 | Absolute |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
133 | 40BD | ReadFlowPressureConfiguration |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|