Loading…

Variable Name: NonNormalModeTimeout

Variable ID: 0x43B4

Variable Label: Test Mode Timeout

Variable Help: Non-normal operation timeout. The maximum length of time that a frequency output pair, digital output pair, analog output or calibration can remain in the test mode. In the event communications are lost between the Ultrasonic meter software and the meter (before a test mode is stopped), the meter will automatically end the test mode after the non-normal operation timeout has expired. This can be from 1 to 30 minutes depending on its settings. By default, the timeout is set to two minutes.

Variable Handling: R/W

Variable Class:

Variable Size: 1

Variable DataType: Unsigned

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
147 4043 ReadMiscellaneousParameters

Variable Write Command List

Command Number Command ID Command Name
200 444D WriteMiscellaneousWriteProtectedParameters