Loading…

Variable Name: IsBlockageDetectionEnabled

Variable ID: 0x404B

Variable Label: Detect Blockage

Variable Help: Disables blockage detection when set FALSE (0). Setting this to TRUE (1) will enable blockage detection if optional flow analysis features are enabled and the meter device number is 3414.

Variable Handling: R/W

Variable Class:

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Disabled
0x0001 Enabled

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
149 404C ReadBlockageConfiguration

Variable Write Command List

Command Number Command ID Command Name
148 4044 WriteBlockageConfiguration