Loading…

Variable Name: AlarmTurnOffHysterisisCount

Variable ID: 0x43E8

Variable Label: Hysteresis Filter Count

Variable Help: Alarm log repetitive alarm filter count. This point, along with alarm log hysteresis filter time span, is used to prevent the alarm log from filling up in the event of a very repetitive alarm (such as the flow temperature fluctuating around one of its alarm limits). If a data point being monitored for the alarm log has this number of alarms within a specified length of time, then alarming is turned off for that point until no new alarms are received for that point within the specified length of time.

Variable Handling: R/W

Variable Class:

Variable Size: 2

Variable DataType: Unsigned

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
183 43EF ReadArchiveLogConfiguration

Variable Write Command List

Command Number Command ID Command Name
182 43E7 WriteArchiveLogConfiguration