Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 PV Analog Channel Saturated
0x0008 PV Analog Channel Fixed
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
161 4040 read_cidra_control
163 4048 read_cidra_device_info
165 4059 read_cidra_pipe_info
167 4064 read_cidra_fluid_prop
169 4073 read_cidra_environment
171 4083 read_cidra_display
173 408D read_cidra_system
175 4090 read_cidra_system_dynamic
177 4099 read_cidra_preamp
179 40B2 read_cidra_flow_algorithm
181 40B7 read_cidra_flow_algo_dynamic
183 40BC read_cidra_flow_cal
185 40D3 read_cidra_sos_algorithm
187 40D6 read_cidra_sos_algo_dynamic
191 40E2 read_cidra_analog_section
193 40E9 read_cidra_input_units
195 40ED read_cidra_flow_nr_filter
197 40F1 read_cidra_flow_damping_filter
199 40FA read_cidra_flow_spike_filter
201 40FE read_cidra_gvf_nr_filter
203 4102 read_cidra_gvf_damping_filter
205 410B read_cidra_gvf_spike_filter
207 4110 read_cidra_sensor
209 411A read_cidra_sensor_spacing
213 4129 read_cidra_measured_values
215 413A read_cidra_sensor_max_min
217 4143 read_cidra_sensor_alpha
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables

Variable Write Command List

None