Loading…

Variable Name: xmtr_specific_status_2

Variable ID: 0x0FB7

Variable Label: Diagnostic Status

Variable Help: Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0080 RAM Test Fail
0x0040 Flash Test Fail
0x0020 Dbase Chksum Err
0x0010 PIC Reset
0x0008 PIC Fail
0x0004 ADC Fail
0x0002 Int Temp Sensor

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 0FCE read_additional_transmitter_status

Variable Write Command List

None