Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 PV Out of Range
0x0002 Non PV Out of Range
0x0004 PV Output Saturated
0x0008 PV Output Fixed
0x0010 More Status Available
0x0020 Device Reset
0x0040 Configuration Changed
0x0080 Device Malfunction

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
130 40EF read_product_code
131 40F0 read_product_name
132 40F1 read_firmware_name
133 40F2 read_application_version
134 40F3 read_compile_date_time
135 40F4 read_OTP_boot_checksum
136 40F5 read_Flash_OS_checksum
137 40F6 read_Boot_version
138 40F7 read_OS_version
140 40F8 read_daughter_board_version
141 40F9 read_pcb_serial_number
150 40FA read_detector_diameter
152 40FB read_detector_diameter_other
154 40FC read_detector_factor
156 40FD read_detector_offset
158 40FE read_amplifier_factor
160 40FF read_detector_current
162 4100 read_power_line_frequency_code
164 4102 read_exitation_frequency_code
166 4104 read_scale_factor
173 4106 read_full_scale_flow
175 4108 read_flow_units
177 410A read_volume_units
179 410C read_unit_multiplier
181 410E read_full_scale_velocity
183 4110 read_low_flow_cut_off
185 4112 read_flow_direction_code
187 4114 read_damping_factor_code
190 4116 read_digital_input_operation_code
192 4118 read_digital_input_status
193 4119 read_analog_customer_offset
195 411B read_analog_customer_span
200 411E read_pulses_per_unit
200 411E read_pulses_per_unit
202 4120 read_pulse_width
202 4120 read_pulse_width
204 4121 read_flow_alarm_min
204 4121 read_flow_alarm_min
204 4121 read_flow_alarm_min
204 4121 read_flow_alarm_min
206 4123 read_flow_alarm_max
206 4123 read_flow_alarm_max
206 4123 read_flow_alarm_max
206 4123 read_flow_alarm_max
208 4125 read_DO_output_mode_code
208 4125 read_DO_output_mode_code
208 4125 read_DO_output_mode_code
208 4125 read_DO_output_mode_code
210 4127 read_DO_operation_code
210 4127 read_DO_operation_code
210 4127 read_DO_operation_code
210 4127 read_DO_operation_code
212 4129 read_full_scale_frequency
214 412B read_hardware_selection_code
214 412B read_hardware_selection_code
220 412D read_port_A_diagnostics
221 412E read_port_B_diagnostics
222 412F read_meter_diagnostics
225 4130 read_Backlight_mode_code
227 4132 read_preset_batch_value
229 4134 read_language_code
231 4136 read_Empty_pipe_mode_code
233 4138 read_empty_pipe_Calibration_Value
235 413A read_full_pipe_Calibration_Value
237 413C read_empty_pipe_measure_Value
238 413D read_empty_pipe_actual_resistance
239 413E read_dynamic_vars
240 413F read_simulation_value_code
243 4142 read_access_code
247 4144 read_random_number
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status

Variable Write Command List