Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 Analog output 1 and its digital representation are outside the operating range limits, and not responding to input
0x0008 Analog output 1 and its digital representation are in fixed mode, and not responsive to input changes
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 408D read_system_information
130 408E read_process_vars
132 4090 read_live_process_vars
134 4091 read_rtc_date_time
136 4093 read_parameter_info
138 4095 read_raw_value
140 4096 read_lab_sample_part1
142 4098 read_do_use_calibration
144 409A read_calibration_constant
146 409C read_life_cycle_diag
148 409D read_device_status
150 409E read_alarm_information
152 40A0 read_warning_information
154 40A2 read_event_information
156 40A3 read_lab_sample_2
158 40A5 read_parameter_live_info
158 40A5 read_parameter_live_info
160 40A6 read_calibration
162 40A8 read_new_calibration
163 40A9 read_device_status_present
164 40AA read_precalib_pulp_type
201 40AD read_help_indexes
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag

Variable Write Command List

None