Variable Name: var_ds_fIoFactor
Variable ID: 0x404E
Variable Label: Io Factor
Variable Help: Io Factor Defines the threshold where the interference radiation detection responds. With the default value of 1.5, the threshold is 1.5 times the active empty count rate and is suitable for most applications. You can adjust the factor for the threshold yourself. Note that a value below 1.5 may trigger faulty switching caused by fluctuations in the measured values. Increasing the factor decreases the sensitivity. Increase the factor if false alarms are triggered by significant fluctuations in the measured values, for example, by agitator blades.
Variable Handling: R/W
Variable Class: Device
Variable Size: 4
Variable DataType: Float
Variable Display Format: |en|.1f
Variable Edit Format: |en|.1f
Variable Unit:
Variable Max:
Variable Min:
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
200 | 422B | cmd_rd_radiation_interference |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
201 | 422C | cmd_wr_radiation_interference |