Loading…
Loading…
Variable Name: device_specific_status_21
Variable ID: 0x1038
Variable Label: Statusgruppe 21
Variable Help: Feldgerätspezifischer Zustand Byte 22- Daten über feldgerätespezifische Informationen wie: Ausfall / Warnungen / Prozeßzustand.
Variable Handling: R
Variable Class: Dynamic | Diagnostic | Device
Variable Size: 1
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0001 | Electronics Power Supply Insufficient Voltage to operate device |
0x0002 | Ambient Temp Out of Range |
0x0004 | Process Temp Warning |
0x0008 | Process Temp Alarm |
0x0010 | Data Simulation Warning |
0x0020 | Alarm Simulation Warning |
0x0040 | Current Output in Fixed Mode |
0x0080 | Primary Current Uncertain |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
48 | 1043 | read_additional_device_status |
Variable Write Command List
None