Variable Name: bp_status
Variable ID: 0x40FD
Variable Label: BP status
Variable Help: BP status !! FOR SERVICE ONLY !! CHANGING OF SERVICE-PARAMETERS MAY HAVE AN EFFECT ON THE OPERATION OF THE PLANT, THE BUS COMMUNICATION AND MAY ENDANGER LIFES.
Variable Handling: R
Variable Class: Dynamic | Device
Variable Size: 2
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | No AD-Input |
0x0001 | Vibrate Cut Off |
0x0002 | Ini BP-Range |
0x0003 | Range Flws Freq |
0x0004 | IniVib In Meas |
0x0005 | Vib In Meas |
0x0006 | IniTmp In Meas |
0x0007 | Tmp In Meas |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
150 | 4118 | read_dsp_data |
Variable Write Command List
None