Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label:

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R/W

Variable Class: Local

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Éxito

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 4094 read_unsigned_char_variables
130 40A1 read_int_variables
132 40C0 read_float_variables
145 40C6 read_special_unit_name
154 40D1 cmd_read_50s_average
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
12 00B4 read_message
13 00B5 read_tag_descriptor_date
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
16 00B8 read_final_assembly_number
33 0FA5 read_transmitter_variables
48 0FCE read_additional_transmitter_status

Variable Write Command List

None