Loading…

Variable Name: diagnosisExtension

Variable ID: 0x400A

Variable Label: Status group 19

Variable Help: Field Device Specific Status Byte 19- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Comm Error Electr-EEPROM
0x0002 Comm Error Sensor-EEPROM
0x0004 max Write-Cycles Electr-EEPROM
0x0008 max Write-Cycles Sensor-EEPROM
0x0010 Electronic Data Error
0x0020 Sensor Data Error
0x0040 User Data Error
0x0080 Factory Reset Data Error

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 0FCE read_additional_transmitter_status

Variable Write Command List

None