Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 PV Analog Channel Saturated
0x0008 PV Analog Channel Fixed
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 4017 read_distribution_map
143 4042 read_display_mode
145 4045 read_split_range
149 4053 read_cwccw
151 4055 read_position_angle
153 4056 read_pid_parameters
157 4061 read_fofc_thresh
159 4067 read_input_char_map
161 4086 read_deadband
163 4088 read_dara
165 408A read_linrot
167 408D read_singdoub
169 4099 read_ffvalue
171 409B read_torq_minmax
183 40A1 read_input_alarm
185 40A7 read_shut_cycle
187 40AB read_op_time
187 40AB read_op_time
187 40AB read_op_time
189 40B7 read_position_alarm
191 40BD read_stroke_counter
191 40BD read_stroke_counter
191 40BD read_stroke_counter
191 40BD read_stroke_counter
193 40C6 read_odometer
193 40C6 read_odometer
193 40C6 read_odometer
193 40C6 read_odometer
193 40C6 read_odometer
195 40D0 read_pst
197 40DC read_tempunit_lcd
199 40DF read_temp_alarm
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
50 1052 read_device_variable_assignments
54 1057 read_device_variable_information
76 1045 read_lock_device_state
95 11DD read_device_communication_statistics

Variable Write Command List

None