Method Name: api_setup

Method ID: 0x4217

Method Label: Petroleum Measurement Setup

Method Help: This method will step the user through setting up the API parameters.


  • {
  • char status[3];
  • int numberChoice;
  • int letterChoice;
  • int enableApi;
  • long var_id[1];
  • char disp_string[100];
  • char disp_string1[100];
  • int slen;
  • int slen1;
  • int deviceChoice;
  • int loop_choice;
  • deviceChoice = 0;
  • slen1 = 100;
  • slen = 100;
  • _set_xmtr_device_status(0xFF,0);
  • _set_xmtr_all_resp_code(0);
  • _set_device_status(0xFF,0);
  • _set_all_resp_code(0);
  • ACKNOWLEDGE(literal_string(1184));
  • _add_abort_method(16809);
  • send(216,status);
  • _get_dictionary_string(858981166,disp_string,slen);
  • _get_dictionary_string(858587213,disp_string1,slen1);
  • numberChoice = SELECT_FROM_LIST(disp_string,disp_string1);
  • if (numberChoice == 0 || numberChoice == 2 || numberChoice == 4)
  • {
  • _get_dictionary_string(858981167,disp_string,slen);
  • _get_dictionary_string(858587214,disp_string1,slen1);
  • letterChoice = SELECT_FROM_LIST(disp_string,disp_string1);
  • _fassign(16905,0.00056);
  • }