Loading…
Loading…
Method Name: read_alarm_severity_meth
Method ID: 0x4446
Method Label: Read Severity
Method Help: Reports the severity level of the selected alarm. The alarms are represented by their alarm number. For example, A26 is 26 and A102 is 102.
- {
- char status[3];
- long var_id[1];
- char disp_string[100];
- char disp_string1[100];
- int slen;
- int slen1;
- int alarmNum;
- slen1 = 100;
- slen = 100;
- _set_xmtr_device_status(0xFF,0);
- _set_xmtr_all_resp_code(0);
- _set_device_status(0xFF,0);
- _set_all_resp_code(0);
- alarmNum = 1;
- _get_dictionary_string(858587223,disp_string,slen);
- _get_local_var_value(disp_string,0,literal_string(619));
- if (alarmNum > 39 && alarmNum < 100 || alarmNum > 140)
- {
- _get_dictionary_string(858783850,disp_string,slen);
- ACKNOWLEDGE(disp_string);
- }