Loading…
Loading…
Method Name: edit_alarm_1_config_method
Method ID: 0x41BA
Method Label: Edit Alarm 1 config.
Method Help:
- {
- DD_STRING disp_string;
- char status[3];
- _set_device_status(0xFF,0);
- _set_all_resp_code(0);
- _set_xmtr_device_status(0xFF,0);
- _set_xmtr_all_resp_code(0);
- alarm_1_config_Value_enum = alarm_1_config_Value;
- disp_string = literal_string(772);
- _get_dev_var_value(disp_string,0,16667);
- alarm_1_config_Value = alarm_1_config_Value_enum;
- device_variable_code = 16;
- send(79,status);
- if (status[0])
- display_response_status(79,status[0]);
- else
Please login for more