Method Name: edit_alarm_1_config_method

Method ID: 0x41BA

Method Label: Edit Alarm 1 config.

Method Help:


  • {
  • DD_STRING disp_string;
  • char status[3];
  • _set_device_status(0xFF,0);
  • _set_all_resp_code(0);
  • _set_xmtr_device_status(0xFF,0);
  • _set_xmtr_all_resp_code(0);
  • alarm_1_config_Value_enum = alarm_1_config_Value;
  • disp_string = literal_string(772);
  • _get_dev_var_value(disp_string,0,16667);
  • alarm_1_config_Value = alarm_1_config_Value_enum;
  • device_variable_code = 16;
  • send(79,status);
  • if (status[0])
  • display_response_status(79,status[0]);
  • else