Method Name: th_measGas
Method ID: 0x148A
Method Label: Select Gas/Unit
Method Help: Selects the Measurement Gas and Unit
- {
- char disp_string1[60];
- int slen1;
- char disp_string2[60];
- int slen2;
- char status[3];
- char more_status[3];
- char more_info[25];
- int number_of_tries;
- long ids[5];
- int resp;
- int i;
- int cmd;
- int uploadStat;
- int maxUnit;
- slen1 = slen2 = 60;
- send_command(48);
- if (_ivar_value(4032) & 0x80)
- {
- _get_dictionary_string(1193083168,disp_string1,slen1);
- DELAY(3,disp_string1);
- process_abort();
- }
- ;
- _set_all_resp_code(0);
- _set_device_status(0xFF,0);
- _set_xmtr_device_status(0xFF,0);
- _set_xmtr_all_resp_code(0);
- send_trans(201,0,status);
- if (status[0] != 0)
- {
- display_response_status(201,status[0]);
- cmd = 201;
- DELAY(2,literal_string(175));
- process_abort();
- }