Loading…

Method Name: Alarms

Method ID: 0x40AC

Method Label: Alarms

Method Help:


  • {
  • int alarm_code_intern;
  • int status_flag_intern;
  • int switch_code_intern;
  • int dispmessage;
  • long variable_identifiers_array[2];
  • _set_xmtr_comm_status(0x7F,0);
  • _set_xmtr_device_status(0xFF,0);
  • _set_xmtr_all_resp_code(0);
  • _set_xmtr_comm_status(0xFF,0);
  • _set_comm_status(0x7F,0);
  • _set_device_status(0xFF,0);
  • _set_all_resp_code(0);
  • _set_comm_status(0xFF,0);
  • dispmessage = 0;
  • send_command(48);
  • status_flag_intern = _ivar_value(4037);
  • alarm_code_intern = _ivar_value(4026);
  • if (status_flag_intern & 0x20)