Method Name: reset_NAMUR_mapping
Method ID: 0x4444
Method Label: Reset to default NAMUR Configuration
Method Help: Reset to default NAMUR Configuration Some Examples (not all diagnostics): Set typical diagnostics to NAMUR State **Maintenance Required** - Redundancy: Sensor 1 not available - Redundancy: Sensor 2 not available - Sensordrift detected - Main diagnostics of Sensor 1 and Sensor 2 * Line Resistance too High * Wire break / Sensor break * Short circuit * Over Sensor Range * Under Sensor Range - .... Set typical diagnostics to NAMUR State **Failure** - Electronics Temperature measurement failure - .... Set typical diagnostics to NAMUR State **Out of Specification** - High Limit: Alarm and warning - Low Limit: Alarm and warning - ....
- {
- char status[3];
- char disp_string[60];
- int use_abort_method;
- int slen;
- slen = 60;
- _set_device_status(0xFF,0);
- _set_all_resp_code(0);
- _set_xmtr_device_status(0xFF,0);
- _set_xmtr_all_resp_code(0);
- _add_abort_method(17462);
- ACKNOWLEDGE(literal_string(1017));
- send(525,status);
- if (status[0])
- {
- display_response_status(525,status[0]);
- _get_dictionary_string(19726342,disp_string,slen);
- DELAY(2,disp_string);
- process_abort();
- }