Loading…
Loading…
名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
self_test_method | 41DA | 自测试 | Commands the RCCT_F3 electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | 详细信息 |
rcct_auto_zero | 4238 | 执行自动归零 | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | 详细信息 |
rcct_fixed_analog1_output | 421F | Analog Out 1 | Set the analog output 1 to a fixed value | msrc_UNKNOWN | 详细信息 |
rcct_fixed_analog2_output | 4220 | Analog Out 2 | Set the analog output 2 to a fixed value | msrc_UNKNOWN | 详细信息 |
rcct_analog_dac_trim1 | 4228 | Trim output 1 | 数字到模拟修正——允许对选择的模拟量输出进行标定,在模拟量输出的操作端点有外部参考。 | msrc_UNKNOWN | 详细信息 |
rcct_analog_dac_trim2 | 4229 | Trim output 2 | 数字到模拟修正——允许对选择的模拟量输出进行标定,在模拟量输出的操作端点有外部参考。 | msrc_UNKNOWN | 详细信息 |
rcct_fix_frequency1 | 4221 | Pulse Out 1 | Outputs a user-programmed frequency to the frequency output. | msrc_UNKNOWN | 详细信息 |
rcct_fix_frequency2 | 4223 | Pulse Out 2 | Outputs a user-programmed frequency to the frequency output. | msrc_UNKNOWN | 详细信息 |
rcct_fix_status1_out | 4222 | Status Out 1 | Outputs a user-selected level to the status output. | msrc_UNKNOWN | 详细信息 |
rcct_fix_status2_out | 4224 | Status Out 2 | Outputs a user-selected level to the status output. | msrc_UNKNOWN | 详细信息 |
rcct_fix_status_in | 4225 | Status Input | Inputs the actual level at the status input. | msrc_UNKNOWN | 详细信息 |
leave_fixed_freq_mode | 423B | msrc_UNKNOWN | 详细信息 | ||
leave_fixed_stat_mode | 423C | msrc_UNKNOWN | 详细信息 | ||
rcct_master_reset | 418F | Master reset | All parameter settings are reset to factory settings. | msrc_UNKNOWN | 详细信息 |
abort_auto_zero | 423A | Aborts Auto Zero operation and continues to use previous zero offset value. | msrc_UNKNOWN | 详细信息 | |
must_send_varcode | 423D | msrc_UNKNOWN | 详细信息 | ||
write_enable_10min | 4190 | Enable wrt 10min | Type the password, if no password defined yet, type all spaces | msrc_UNKNOWN | 详细信息 |
change_to_new_password | 4191 | New password | Type in new password, up to 8 characters are allowed | msrc_UNKNOWN | 详细信息 |
err_abort_without_func_key_disp | 423E | Aborting | msrc_UNKNOWN | 详细信息 | |
normal_exit_for_chg_passwd | 423F | Exiting | msrc_UNKNOWN | 详细信息 | |
rcct_LV_adjust | 41BF | Temp LV Adjust | Connect a well-known PT100 termistor to the input. | msrc_UNKNOWN | 详细信息 |
rcct_HV_adjust | 41C0 | Temp HV Adjust | Connect a well-known PT100 termistor to the input. | msrc_UNKNOWN | 详细信息 |
LCD_test_method | 41C6 | LCD/Key Test | Starts a selftest routine on the LCD panel. | msrc_UNKNOWN | 详细信息 |
rcct_clear_history | 41DD | Clear History | msrc_UNKNOWN | 详细信息 | |
rcct_read_history_ord | 41DB | Hist Overview ord | msrc_UNKNOWN | 详细信息 | |
enter_serv_password | 41B6 | Enter service PW | Password to inhibit any change in parameters without the correct password | msrc_UNKNOWN | 详细信息 |
change_serv_password | 41B5 | Set service PW | Password to inhibit any change in parameters without the correct password | msrc_UNKNOWN | 详细信息 |
set_conc_version | 4233 | Conc Version | msrc_UNKNOWN | 详细信息 | |
set_tokuchu_version | 428E | Total display | Set tokuchu version | msrc_UNKNOWN | 详细信息 |
warning_message | 1017 | 设置回路为手动 | msrc_UNKNOWN | 详细信息 | |
leave_fixed_current_mode | 1003 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
fixed_analog_output | 1008 | 固定模拟量输出 | 固定模拟量输出——允许用户将选择的模拟量输出手动调节至选择的常数输出值。 | msrc_UNKNOWN | 详细信息 |
leave_analog_fixed_current_mode | 1009 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
return_to_normal | 1016 | 中止返回正常 | msrc_UNKNOWN | 详细信息 | |
名称 | ID | 标签 | 描述 | 类型 | 源代码 |