Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
send_warning | 1399 | Send warning | Send Warning- Yields a units code notice to the User. | msrc_UNKNOWN | Details |
eja_press_keypad_pre_warning | 4046 | Set loop to manual | msrc_UNKNOWN | Details | |
eja_press_keypad_post_warning | 4047 | NOTE-Loop may be returned to automatic control | msrc_UNKNOWN | Details | |
eja_self_test | 4005 | Self test | Commands the EJA electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
write_enable_10min | 404B | Enable wrt 10min | msrc_UNKNOWN | Details | |
change_to_new_password | 404C | New password | msrc_UNKNOWN | Details | |
err_abort_without_func_key_disp | 4057 | Aborting | msrc_UNKNOWN | Details | |
normal_exit_for_chg_passwd | 4058 | Exiting | msrc_UNKNOWN | Details | |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
scaled_dac_trim | 1005 | Scaled D/A trim | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
sensor_a_lower_sensor_trim | 1787 | Lower sensor trim | Pressure Sensor Lower Trim- Calibrate the pressure sensor. | msrc_UNKNOWN | Details |
sensor_a_upper_sensor_trim | 1789 | Upper sensor trim | Pressure Sensor Upper Trim- Calibrate the pressure sensor. | msrc_UNKNOWN | Details |
leave_trim_mode | 1788 | Exit trim mode | Exit Trim Mode- Notifies the User that the trim is finished. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |