Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
zero_trim_at_zero | 4045 | Ajuste zero | Zero trim - Make the sensor input the new zero input reference. Sensor gain trim point is adjusted. | msrc_UNKNOWN | Details |
sv_upper_trim | 4047 | Temp upper trim | msrc_UNKNOWN | Details | |
sv_lower_trim | 4046 | Temp low trim | msrc_UNKNOWN | Details | |
transmitter_self_test | 400A | Self test | msrc_UNKNOWN | Details | |
master_reset | 400B | Master reset | msrc_UNKNOWN | Details | |
reset_flag | 4007 | Reset config chgd | Resets the configuration changed flag | msrc_UNKNOWN | Details |
write_protect_contrl | 401E | Write prtct cntrl | Changes the write protect setting of the transmitter | msrc_UNKNOWN | Details |
comp_mode_toggle | 403A | Comp mode on/off | Turns on/off digital compensation of input errors. | msrc_UNKNOWN | Details |
toggle_pv_damping | 4040 | Damp mode on/off | Turns on/off damping of input | msrc_UNKNOWN | Details |
select_alarm_code | 4019 | Select alarm code | This command performs the function of setting the PV Analog Output Current Failure Alarm mode of the device to allow a prespecified current condition upon a hardware failure condition as indicated by an over pressure condition, sensor malfunction or other condition requiring notification to the analog control system | msrc_UNKNOWN | Details |
restore_settings | 4009 | Restr fctry set | This command will restore all original factory settings to the slave device. It will destroy, by overwriting, any user calibration, notes, messages, tags, or other modifications which have been entered into the slave device by the user | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abortar retorno para normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Ajustar malha para manual | msrc_UNKNOWN | Details | |
loop_test | 1002 | Teste de malha | Teste de malha- Permite o usuário a manipular manualemnte a saída analógica para o valor de saída de constante selecionada | msrc_UNKNOWN | Details |
dac_trim | 1004 | Ajuste D/A | Digital para ajuste analógico- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero calibrate | Zero calibrate - Make the sensor input the new zero input reference. Sensor gain trim point is not adjusted. | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Deixar o modo fixado atual | Modo atual de deixar fixado- Leva uma saída analógica para fora do modo onde a saída foi um valor constant, e retorna a saída para o modo onde a saída segue a entrada | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Aplicar valores | Valores aplicados- Realize um reajuste do dispositivo aplicando um valor faixa superior e valores de faixa inferiors para a entrada de dispositivo | msrc_UNKNOWN | Details |
sensor_a_upper_sensor_trim | 1789 | Gain trim | Pressure Sensor Upper Trim- Calibrate the pressure sensor. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |