Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
self_test | 4076 | Status | Self Test- Directs the HTZ electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
give_unit_notice | 403B | msrc_UNKNOWN | Details | ||
SelectUnitsMethod | 4077 | EGU Selection | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | msrc_UNKNOWN | Details |
OutputTrimResetMethod | 4078 | AO1 Trim Reset | User can reset output 1 trim to factory trim. | msrc_UNKNOWN | Details |
Output2TrimResetMethod | 4079 | AO2 Trim Reset | User can reset output 2 trim to factory trim. | msrc_UNKNOWN | Details |
device_variable_trim | 1080 | PV Trim | Temperature input trim- Allows for the calibration measurement of a device variable to be adjusted linearly. The trim point that is sent to the device must represent the presently applied process variable value. | msrc_UNKNOWN | Details |
humidity_variable_trim | 407A | SV Trim | Relative Humidity trim- Allows for the calibration measurement of a device variable to be adjusted linearly. The trim point that is sent to the device must represent the presently applied process variable value. | msrc_UNKNOWN | Details |
dewpoint_variable_trim | 407B | TV Trim | Dew Point trim- Allows for the calibration measurement of a device variable to be adjusted linearly. The trim point that is sent to the device must represent the presently applied process variable value. | msrc_UNKNOWN | Details |
device_variable_trim_reset | 1083 | Sensor Trim Reset | Device Variable Trim Reset- Allows for the device variable to be set to its default factory trim. | msrc_UNKNOWN | Details |
Ao2_dac_trim | 407C | AO2 Trim | msrc_UNKNOWN | Details | |
ao2leave_fixed_current_mode | 407D | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
ao2loop_test | 407E | AO2 Loop Test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
loop_test | 1002 | AO1 Loop Test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
dac_trim | 1004 | AO1 Trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |