Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
self_test | 4019 | Self test | Commands the 4301 electronics to per- form a selftest. Re- ports any errors that occured. | msrc_UNKNOWN | Details |
master_reset | 401A | Master reset | Commands the 4301 electronics to reset and perform a self- test. Reports any errors that occured. | msrc_UNKNOWN | Details |
reset_total | 40F3 | Reset_Totalization | Commands the Total- ization to reset. | msrc_UNKNOWN | Details |
read_from_sensor | 40EE | Read_from_Sensor | Read the sensor mem- ory data to the op- erating memory. | msrc_UNKNOWN | Details |
write_on_sensor | 40EF | Write_on_Sensor | Write the operating memory data in the sensor memory. | msrc_UNKNOWN | Details |
full_read_sensor | 40F0 | Full_Read_Sensor | Transfer data from sensor to operating memory | msrc_UNKNOWN | Details |
trim_pres_char | 40E2 | Characteriz._Trim | Characterization of the sensor curve. | msrc_UNKNOWN | Details |
return_char | 4105 | Abort Characterization | msrc_UNKNOWN | Details | |
without_reference | 40D4 | WITHOUT_REFERENCE | msrc_UNKNOWN | Details | |
with_reference | 40D5 | WITH_REFERENCE | msrc_UNKNOWN | Details | |
without_reference_1 | 40D6 | WITHOUT_REFERENCE | msrc_UNKNOWN | Details | |
with_reference_1 | 40D7 | WITH_REFERENCE | msrc_UNKNOWN | Details | |
return_loop | 4106 | Return loop to auto | msrc_UNKNOWN | Details | |
new | 40D9 | NEW | msrc_UNKNOWN | Details | |
edit | 40D8 | EDIT | msrc_UNKNOWN | Details | |
meth_setpoint | 40DF | SP_Tracking is | msrc_UNKNOWN | Details | |
meth_function | 400A | Function | msrc_UNKNOWN | Details | |
meth_totalizer_mode | 40F1 | Totalization is | msrc_UNKNOWN | Details | |
meth_damping | 4013 | Damp. | msrc_UNKNOWN | Details | |
meth_pressure_user_unit | 40FA | PRESSURE | msrc_UNKNOWN | Details | |
meth_flow_user_unit | 40FB | FLOW | msrc_UNKNOWN | Details | |
meth_speed_user_unit | 40FC | SPEED | msrc_UNKNOWN | Details | |
meth_volume_user_unit | 40FD | VOLUME | msrc_UNKNOWN | Details | |
meth_level_user_unit | 40FE | LEVEL | msrc_UNKNOWN | Details | |
meth_mass_user_unit | 40FF | MASS | msrc_UNKNOWN | Details | |
meth_mass_flow_user_unit | 4100 | MASS_FLOW | msrc_UNKNOWN | Details | |
meth_density_user_unit | 4101 | DENSITY | msrc_UNKNOWN | Details | |
meth_misc_user_unit | 4102 | MISC. | msrc_UNKNOWN | Details | |
meth_no_unit_user_unit | 4104 | NO_UNIT | msrc_UNKNOWN | Details | |
meth_special_user_unit | 4103 | SPECIAL | msrc_UNKNOWN | Details | |
meth_volume_total_unit | 40F5 | VOLUME | msrc_UNKNOWN | Details | |
meth_mass_total_unit | 40F6 | MASS | msrc_UNKNOWN | Details | |
meth_no_unit_total_unit | 40F8 | NO_UNIT | msrc_UNKNOWN | Details | |
meth_special_total_unit | 40F7 | SPECIAL | msrc_UNKNOWN | Details | |
meth_password_1 | 40EA | LEVEL_1 | msrc_UNKNOWN | Details | |
meth_password_2 | 40EB | LEVEL_2 | msrc_UNKNOWN | Details | |
meth_password_3 | 40EC | LEVEL_3 | msrc_UNKNOWN | Details | |
meth_multidrop | 40D2 | Select address | msrc_UNKNOWN | Details | |
zero_trim | 1006 | Zero Pressure | Is very similar to Lower trim, but it assumes that the applied pressure is zero.The user does not have to enter any value | msrc_UNKNOWN | Details |
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
dac_trim | 1004 | 4mA | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
scaled_dac_trim | 1005 | 20mA | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
send_warning | 1399 | Send warning | Send Warning- Yields a units code notice to the User. | msrc_UNKNOWN | Details |
sensor_a_lower_sensor_trim | 1787 | Lower Pressure | Is used to trim the reading at the lower range.The user informs the transmit -ter the correct rea -ding for the apllied pressure via HTT. | msrc_UNKNOWN | Details |
sensor_a_upper_sensor_trim | 1789 | Upper Pressure | Is used to trim the reading at the upper range.The user informs the transmitter the correct reading for the apllied pressure via HTT. | msrc_UNKNOWN | Details |
leave_trim_mode | 1788 | Exit trim mode | Exit Trim Mode- Notifies the User that the trim is finished. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |