Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
sensor_setup_meth | 42D8 | Sensor Selection | This selection must be made to enable calibration parameters to be visible for the selected sensor type. | msrc_UNKNOWN | Details |
set_chana | 42D9 | Channel A Setup | This function will allow the user to setup channel A to act as a milliamp output. The appropriate configuration parameters will be displayed to the user once this selection has been made. | msrc_UNKNOWN | Details |
set_chanb | 42DA | Channel B Setup | This function will allow the user to setup channel B to act as a frequency output, discrete input or a discrete output. The appropriate configuration parameters will be displayed to the user once this selection has been made. | msrc_UNKNOWN | Details |
mmi_auto_zero | 42DB | Perform auto zero | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_a | 42DD | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_b | 42DF | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_c | 42E0 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_d | 42E1 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_fd | 42E2 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_offset_cal | 42E3 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_slope_cal | 42E4 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
fix_do_1 | 42E5 | Fix Discrete Out 1 | Outputs a user-programmed discrete state to the discrete output. | msrc_UNKNOWN | Details |
leave_fixed_do1_mode | 42E6 | Exits fixed mode and returns the discrete output to its active state. | msrc_UNKNOWN | Details | |
fix_frequency | 42E7 | Fix Frequency Out | Outputs a user-programmed frequency to the frequency output. | msrc_UNKNOWN | Details |
fix_ao_1 | 42E9 | Fix Analog Out 1 | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
analog_1_trim | 42EB | Trim Analog Out 1 | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
self_test | 42EC | Self test | Instructs transmitter to perform internal self test. | msrc_UNKNOWN | Details |
start_total | 42ED | Start totalizer | Enables the internal totalizers to begin counting. | msrc_UNKNOWN | Details |
stop_total | 42EE | Stop totalizer | Prevents the internal totalizers from counting. | msrc_UNKNOWN | Details |
reset_all_total | 42EF | Reset all totals | Resets all totalizers | msrc_UNKNOWN | Details |
reset_mass_total | 42F0 | Reset mass total | Resets mass flow totalizer | msrc_UNKNOWN | Details |
reset_vol_total | 42F1 | Reset volume total | Resets volumne flow totalizer | msrc_UNKNOWN | Details |
reset_gas_std_vol_total | 42F2 | Reset gas volume total | Resets internal totalizers. | msrc_UNKNOWN | Details |
alarm1_stat | 42F3 | Status Event1 | When set, indicates that Event 1 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
alarm2_stat | 42F4 | Status Event2 | When set, indicates that Event 2 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
do1_stat | 42F5 | Status DO1 | When set, indicates that DO 1 has been triggered. | msrc_UNKNOWN | Details |
view_xmtr_status | 42F6 | View status | Reports any currently active device status information. | msrc_UNKNOWN | Details |
abort_auto_zero | 42DC | Aborts Auto Zero operation and continues to use previous zero offset value. | msrc_UNKNOWN | Details | |
leave_fixed_freq_mode | 42E8 | Exits fixed mode and returns the frequency output to its active state. | msrc_UNKNOWN | Details | |
mmi_leave_analog_fixed_current_mode1 | 42EA | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
abort_send | 42DE | msrc_UNKNOWN | Details | ||
must_send_fault_level | 40DF | msrc_UNKNOWN | Details | ||
must_send_pv | 4001 | msrc_UNKNOWN | Details | ||
must_send_sv | 4003 | msrc_UNKNOWN | Details | ||
must_send_tv | 4005 | msrc_UNKNOWN | Details | ||
must_send_event_var | 42F7 | msrc_UNKNOWN | Details | ||
must_send_units | 4009 | msrc_UNKNOWN | Details | ||
must_send_scaling | 40C4 | msrc_UNKNOWN | Details | ||
write_alarm_severity_meth | 42F8 | Write Severity | Allows the user to change the severity level of an alarm. The alarms are represented by their alarm number. For example, A26 is 26 and A102 is 102. | msrc_UNKNOWN | Details |
read_alarm_severity_meth | 42F9 | Read Severity | Reports the severity level of the selected alarm. The alarms are represented by their alarm number. For example, A26 is 26 and A102 is 102. | msrc_UNKNOWN | Details |
review_alarm_severity_meth | 42FA | Review Severity (All) | Reports the severity level of all the alarms. | msrc_UNKNOWN | Details |
write_discrete_assignment_meth | 42FB | Assign Discretes | Assigns a discrete to an action. Select none for no discrete assignment. | msrc_UNKNOWN | Details |
read_discrete_assignment_meth | 42FC | Read Action Assign | For a selected discrete action, reports the associated discrete assignment. | msrc_UNKNOWN | Details |
review_discrete_assignment_meth | 42FD | Read Action Assign (All) | Cycles through the discrete actions and reports the associated discrete assignments. | msrc_UNKNOWN | Details |
select_acknowledge_alarm | 42FE | Acknowledge the selected alarm | msrc_UNKNOWN | Details | |
perform_varDiagnostic_Action_Code | 42FF | Perform Diagnostic Action | msrc_UNKNOWN | Details | |
read_modbus_register | 4300 | Read Modbus Data Value | msrc_UNKNOWN | Details | |
write_modbus_register | 4301 | Write Modbus Data Value | msrc_UNKNOWN | Details | |
write_simulation_params_massflow | 4302 | Simulate Mass Flow | msrc_UNKNOWN | Details | |
write_simulation_params_temp | 4303 | Simulate Temperature | msrc_UNKNOWN | Details | |
write_simulation_params_Density | 4304 | Simulate Density | msrc_UNKNOWN | Details | |
read_di_1_state | 4402 | Read Discrete In | Reads the state of the Discrete Input. | msrc_UNKNOWN | Details |
refresh_alarm_history | 4403 | Refresh Alarm Event Log | Uploads the 50 alarm history records from the device. This method takes approximately 30 sec to run. | msrc_UNKNOWN | Details |
set_FO_Fault | 449B | Set Fault Params | msrc_UNKNOWN | Details | |
meth_meter_verification | 44E6 | Meter Verification | Starts meter verification and shows the result PASS or FAIL. This procedure takes upto 4 minutes. | msrc_UNKNOWN | Details |
abort_meter_verification | 44E7 | msrc_UNKNOWN | Details | ||
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
scaled_dac_trim | 1005 | Scaled AO1 trim | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |