Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
Refresh_History_table | 4002 | Refresh History | Displays a history of most recent diagnostic events. For each event, the time when the event occurred and the duration of the event are shown. The table of history events displays the most recent event at the top with successively preceding events in descending order. | msrc_UNKNOWN | Details |
HistReset_method | 4003 | Reset History | Clears entries in Status History and resets the run time to zero. | msrc_UNKNOWN | Details |
set_rtc_history_method | 4004 | Set Clock | Sets the Real-Time Clock in the device. | msrc_UNKNOWN | Details |
save_datalog_parameters_method | 40B4 | Save Data Log Params | msrc_UNKNOWN | Details | |
save_datalog_time_method | 40B5 | Save Data Log Time | msrc_UNKNOWN | Details | |
refresh_echo_graph_method | 469A | Refresh Graph | Click to refresh Echo Curve. | msrc_UNKNOWN | Details |
zoom_echo_graph_method | 469B | Zoom | Allows user to zoom in and out of a specific portion of the Echo Curve. | msrc_UNKNOWN | Details |
refresh_echo_history_graph_method | 46AF | Refresh Graph | Click to refresh Echo Curve. | msrc_UNKNOWN | Details |
zoom_echo_history_graph_method | 46B0 | Zoom | Allows user to zoom in and out of a specific portion of the Echo Curve. | msrc_UNKNOWN | Details |
save_reference_echo_method | 469C | Save Ref Echo Curve | Method to save a reference echo curve in the device. The reference echo curve will be retained until over-written by a new reference echo curve. | msrc_UNKNOWN | Details |
refresh_echo_history_method | 46B2 | Refresh History | Method to re-read the echo history summary. | msrc_UNKNOWN | Details |
delete_echo_history_method | 46B4 | Delete History | Allows the History information to be cleared and reset. | msrc_UNKNOWN | Details |
set_rtc_echo_history_method | 46B5 | Set Clock | Sets the Real-Time Clock in the device. | msrc_UNKNOWN | Details |
sensor_input_method | 4913 | Sensor Input | msrc_UNKNOWN | Details | |
transmitter_dac_trim_method | 492E | Adjust Analog Output | Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output. | msrc_UNKNOWN | Details |
read_dac_trim_values_method | 4977 | Read DAC trim values | Reads the values for DAC trim | msrc_UNKNOWN | Details |
TempReset_method | 4944 | Reset Max/Min Temps | Reset the maximum and minimum temperatures measured in the electronics compartment to the present temperature. | msrc_UNKNOWN | Details |
NewProbeReset_method | 492F | Reset New Probe Diagnostic | Clears the diagnostic that indicates a new probe has been attached. Updates the memory in the transmitter to match the probe. | msrc_UNKNOWN | Details |
FactoryReset_method | 4930 | Factory Reset | Reset the device to factory default settings. If using a HART host, disconnect and then reconnect the host after performing the reset. | msrc_UNKNOWN | Details |
ConfigReset_method | 492C | Reset Parameters | Reset the device to factory calibrated settings. If using a HART host, disconnect and then reconnect the host after performing the reset. | msrc_UNKNOWN | Details |
reset_config_changed_method | 4936 | Reset Config Changed | Resets the Configuration Changed bit in the Device Status | msrc_UNKNOWN | Details |
set_rtc_method | 40B3 | Set Clock | Sets the Real-Time Clock in the device. | msrc_UNKNOWN | Details |
reset_NE107mapping | 4940 | Reset NE 107 Mapping | Sets the NE 107 mapping to default values. | msrc_UNKNOWN | Details |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Leaving fixed current mode | Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input. | msrc_UNKNOWN | Details |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
transmitter_loop_test | 1023 | Analog Output Test | Allows the User to manually manipulate the Analog Output to a selected constant output value. | msrc_UNKNOWN | Details |
setup_wizard | 48FC | Setup Wizard | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |