Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
met_mo_get | 406F | msrc_UNKNOWN | Details | ||
met_mo_get_10 | 4070 | msrc_UNKNOWN | Details | ||
met_mo_get_20 | 4071 | msrc_UNKNOWN | Details | ||
met_mo_set | 4072 | msrc_UNKNOWN | Details | ||
met_mo_get_2 | 4074 | msrc_UNKNOWN | Details | ||
met_mo_set_2 | 4075 | msrc_UNKNOWN | Details | ||
met_basic_config | 407F | Advanced Configuration | Advanced configuration for Device Start up and Commissioning | msrc_UNKNOWN | Details |
met_masks_edit | 4092 | Ajust Status Masks | msrc_UNKNOWN | Details | |
met_ack_more_status | 4091 | Ack. more status | This Method allows to reset the more Status available Flag (bit 4 of dev. status byte) | msrc_UNKNOWN | Details |
met_reset_cfg_changed | 4095 | Reset Configuration Changed Flag | This command resets the Configuration Changed Flag (bit 6 of dev. status byte), associated with the device issuing this command | msrc_UNKNOWN | Details |
met_reset_device | 408B | Reset device | This command performs device reset | msrc_UNKNOWN | Details |
met_internal_array_view | 408D | View Values | Method to view Internal Array Values | msrc_UNKNOWN | Details |
met_internal_array_edit | 408E | Edit Value | Method to change Internal Array Values | msrc_UNKNOWN | Details |
met_m_to_internal_format | 40A0 | Encode meters | Encode meters into the internal sensor representation | msrc_UNKNOWN | Details |
met_m_from_internal_format | 40A1 | Decode meters | Decode meters from the internal sensor representation | msrc_UNKNOWN | Details |
met_edit_base_height | 407E | Change Base Height | Base Height is a Distance between a sensor base plane and Tank Bottom | msrc_UNKNOWN | Details |
met_edit_L_min | 40A2 | Change L min | L min is a Minimal Distance, taken into Account for Distance Measuring | msrc_UNKNOWN | Details |
met_edit_L_max | 40A3 | Change L max | L max is a Maximal Distance, taken into Account for Distance Measuring | msrc_UNKNOWN | Details |
met_edit_tim_stab | 40A4 | Set Jump Timeout | Protective Timeout against abrupt change in level readings because of occasional loss of or change in echo signal | msrc_UNKNOWN | Details |
met_edit_kr3_user | 40A5 | Minimum Signal | Minimum Signal Amplitude for level calculations | msrc_UNKNOWN | Details |
met_show_echo_amplitude | 4097 | show Echo Amplitude Value | Amplitude of the Echo Signal, received by the Level Transmitter | msrc_UNKNOWN | Details |
met_show_pll_errors | 4098 | PLL Errors | PLL Errors count during single measuring cycle in HF Unit of the Level Transmitter | msrc_UNKNOWN | Details |
met_application | 4087 | Select Application | Sensor Application is one of: Water solution, acid - Agitator; Water solution, acid; Petrochemical, oil; Solid product - Crusher; Solid product; | msrc_UNKNOWN | Details |
met_mal_main | 40A9 | Minimum Amplitude Line Calcutation | Semi Automatical Minimum Echo Signal Amplitude Line Calcutation | msrc_UNKNOWN | Details |
met_mal_auto | 40AA | Calculate Minimum Amplitude Line | Recalculate Minimum Echo Amlitude Line in semiautomatic mode | msrc_UNKNOWN | Details |
met_mal_default | 40AC | Return to Factory Default Minimum Amplitude Line | Return to Factory Default Minimum Amplitude Line in the Case of inappropriate Minimum Amplitude Line | msrc_UNKNOWN | Details |
met_mal_previous | 40AB | Return to previous Minimum Amplitude Line | Return to previous Minimum Amplitude Line in case of mistakes during Minimum Amplitude Line calculations | msrc_UNKNOWN | Details |
met_vessel_type | 40CD | Select Vessel Type | Vessel Geometry, used in volume calculation | msrc_UNKNOWN | Details |
met_volume | 4089 | Volume computation setup | Set vessel geometry, dimensions and sensor reference point | msrc_UNKNOWN | Details |
met_encode | 40CE | Method encode | Encode big numbers into the internal sensor representation | msrc_UNKNOWN | Details |
met_decode | 40CF | Method decode | Decode big numbers from the internal sensor representation | msrc_UNKNOWN | Details |
met_relay_output | 408A | Relay Output setup | Set vessel geometry and dimensions | msrc_UNKNOWN | Details |
met_l_min_read | 40DA | l_min read | Method to read l_min (minimum distance taken into account for distance calculation) from the Device | msrc_UNKNOWN | Details |
met_l_max_read | 40DC | l_max read | Method to read l_max (maximum distance taken into account for distance calculation) from the Device | msrc_UNKNOWN | Details |
met_base_height_read | 40E0 | Base Height read | Method to read Base Height from the Device | msrc_UNKNOWN | Details |
met_base_height_write | 40E1 | Base Height write | Method to write Base Height into the Device | msrc_UNKNOWN | Details |
met_zl0_read | 40E3 | zl0 read | Method to read Distance Offset due to Antenn | msrc_UNKNOWN | Details |
met_one_coef_length_read | 40E5 | One coefficient read | Method to read Length of one spectrum coefficient | msrc_UNKNOWN | Details |
met_refresh_graph | 40F1 | Refresh Graph Data | msrc_UNKNOWN | Details | |
met_spectrum_read | 40F2 | spectrum_read | msrc_UNKNOWN | Details | |
met_spectrum_decode | 40F3 | Decode Spectrum | msrc_UNKNOWN | Details | |
met_get_mal_value | 411D | ограничительная линия включает kk01,kr,kr3_1,kr3_user,kr_pomehaвозвращает сигнальные числаn-номер коэф.fl=0 - полное ограничение(kk01 и kr3,kr3_1,kr3_user,kr_pomeha)fl=1 - только kk01fl=2 - только kr3,kr3_1,kr_pomeha,kr3_user | msrc_UNKNOWN | Details | |
met_mal_read | 411F | mal_read | msrc_UNKNOWN | Details | |
met_mal_decode | 4120 | mal_decode | msrc_UNKNOWN | Details | |
met_graph_prepare | 40F0 | graph_prepare | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |