Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
set_pressure_units | 4030 | Set pressure units | Change units of Pressure Value | msrc_UNKNOWN | Details |
set_temperature_units | 4031 | Set temp units | Change units of Temperature Value | msrc_UNKNOWN | Details |
set_density_factor | 4032 | Density Factor | msrc_UNKNOWN | Details | |
set_display_readout | 4033 | Display Readout | The Klay Series 2000 has various readouts for the display. | msrc_UNKNOWN | Details |
klay_dac_trim | 4034 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
write_protection | 404E | Change write prot | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. | msrc_UNKNOWN | Details |
set_damping_value | 404A | Set damping value | Set damping value. 0 <= Damping <= 25 | msrc_UNKNOWN | Details |
set_lineairisation | 404B | Lineairisations | There are 4 kinds of lineairisations, no lineairisation, cilindrical tank and vertical tank with (spherical) cone. | msrc_UNKNOWN | Details |
set_reverse_output | 404D | Set reverse output | Reverse output (20-4 mA). Not possible when polling address is not equal zero | msrc_UNKNOWN | Details |
applied_zero | 4047 | Zero | Applied values- Perform a device rerange by applying the desired Span(URV-LRV) and Zero(LRV) to the device input. | msrc_UNKNOWN | Details |
applied_span | 4048 | Span | Applied values- Perform a device rerange by applying the desired Span(URV-LRV) and Zero(LRV) to the device input. | msrc_UNKNOWN | Details |
zero_enter | 403A | Zero | Adjust Zero (4 mA) without testpressure | msrc_UNKNOWN | Details |
span_enter | 403B | Span | Adjust Span(URV-LRV) without testpressure | msrc_UNKNOWN | Details |
cancel_mounting_position | 404C | Mounting position | All Klay transmitters are calibrated vertically. When a transmitter of the Series 2000 is installed horizontally, there will be a small mounting effect on the zero (4 mA). For example the transmitter shows 4.03 mA instead of 4.00 mA. This can be easily canceled with this correction | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |