名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
mth_set_alarm_mode | 407B | msrc_UNKNOWN | 详细信息 | ||
send_gen_name_to_device | 408C | msrc_UNKNOWN | 详细信息 | ||
send_gen_unit_string_to_device | 4091 | msrc_UNKNOWN | 详细信息 | ||
send_gen_mA_used | 4097 | msrc_UNKNOWN | 详细信息 | ||
send_cmd_scroll_sensor_type | 40B9 | msrc_UNKNOWN | 详细信息 | ||
send_tgt_conc | 40BF | msrc_UNKNOWN | 详细信息 | ||
mnu_Refresh_optical_Data | 40E1 | Refresh | msrc_UNKNOWN | 详细信息 | |
enter_passcode | 40D3 | User Login | Allows the user to switch to different login level, Level 0 is default login level | msrc_UNKNOWN | 详细信息 |
clear_alarm | 40D1 | Reset Alarm/Fault(s) | msrc_UNKNOWN | 详细信息 | |
event_history | 40D8 | Event History | Event History lists all events, alarms or faults,that are available on XNX. | msrc_UNKNOWN | 详细信息 |
set_inhibit_mode | 40E2 | Inhibit Device | Set the device into Inhibit Mode | msrc_UNKNOWN | 详细信息 |
force_mA_output | 40E3 | Force mA O/P | Force the analog output current 1 to 22mA in 1mA steps | msrc_UNKNOWN | 详细信息 |
force_relay | 40E4 | Force Relay | Forcing specific relays to energized/de-energized state | msrc_UNKNOWN | 详细信息 |
alarm_simulation | 40E5 | Alarm/Fault Simulation | Simulate different Alarms and Faults | msrc_UNKNOWN | 详细信息 |
end_alarm_simulation | 40F8 | End Alarm/Fault Simulation | msrc_UNKNOWN | 详细信息 | |
PreGasCalibrate | 40F9 | msrc_UNKNOWN | 详细信息 | ||
CalibrationProcess | 40FA | msrc_UNKNOWN | 详细信息 | ||
ExitCalibrationProcedure | 40D0 | msrc_UNKNOWN | 详细信息 | ||
startstopbumptest | 40FC | msrc_UNKNOWN | 详细信息 | ||
end_bump_test | 40FD | End Bump Test | Ending Bump Test. | msrc_UNKNOWN | 详细信息 |
calibrate_mA_output | 40E8 | Calibrate mA Output | Calibrate 4 and 20mA output with DAC offset | msrc_UNKNOWN | 详细信息 |
startstopalignexcel | 40FE | msrc_UNKNOWN | 详细信息 | ||
soft_reset | 40E9 | Soft Reset | msrc_UNKNOWN | 详细信息 | |
config_security | 40EB | Config Security | Allows the user to change the password. | msrc_UNKNOWN | 详细信息 |
set_range_alarm | 40EC | Set Range & Alarm | Set Range and Alarm, applicable to all sensor | msrc_UNKNOWN | 详细信息 |
read_alarm_mode | 40FF | Relay Alarm Config. | msrc_UNKNOWN | 详细信息 | |
set_fieldbus_option | 40ED | Fieldbus Option | Set the Fieldbus Options | msrc_UNKNOWN | 详细信息 |
mthd_accept_new_sensor | 4100 | Accept New Sensor | Accept New Sensor | msrc_UNKNOWN | 详细信息 |
gas_selection | 40F0 | Gas Selection | Selection of gas to be measured by connected sensor | msrc_UNKNOWN | 详细信息 |
set_beam_block | 40F1 | Set Excel Param | Set Excel Beam Block Options | msrc_UNKNOWN | 详细信息 |
set_path_length | 40F2 | Set Path Length | Set the path length, applicable for open path sensors like Excel. Applicable minimum Authorization : Level 2 | msrc_UNKNOWN | 详细信息 |
set_mA_sts_level | 40F3 | Config mA Levels | Configure mA Status Level. | msrc_UNKNOWN | 详细信息 |
set_calib_intv | 40F4 | Set Calibr Interval | Set Calibration Interval. Days between two Gas Calibrations or Bump Tests (0-Disable) | msrc_UNKNOWN | 详细信息 |
set_date_time | 40F5 | Set Date-Time | Displays current time and date, actual time stored is in seconds since JAN 1, 1970. NOTE: Valid till 31st December 2037.. | msrc_UNKNOWN | 详细信息 |
return_to_normal | 1016 | 中止返回正常 | msrc_UNKNOWN | 详细信息 | |
leave_fixed_current_mode | 1003 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
auto_control | 40F7 | Return to auto control | msrc_UNKNOWN | 详细信息 | |
out_of_inhibit | 40FB | Out of Inhibit Mode | msrc_UNKNOWN | 详细信息 | |
send_warning | 1399 | 发送警告 | 发送警告——产生发送给用户的单位代码通知。 | msrc_UNKNOWN | 详细信息 |
unit_limit | 4101 | Unit Sensor Limit | Select the sensor and its acceptable units | msrc_UNKNOWN | 详细信息 |
set_date_format | 4025 | Set Date-Time | Displays current time and date, actual time stored is in seconds since JAN 1, 1970. NOTE: Valid till 31st December 2037.. | msrc_UNKNOWN | 详细信息 |
warning_message | 1017 | 设置回路为手动 | msrc_UNKNOWN | 详细信息 | |