Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
thAdd1900 | 4025 | msrc_UNKNOWN | Details | ||
thSub1900 | 4026 | msrc_UNKNOWN | Details | ||
am_exit_chng_mode | 4032 | msrc_UNKNOWN | Details | ||
th_chng_sensor | 401A | Sensor Replacement | Replace the sensor with a like sensor or a new type. (Attention: Sensor Lock) | msrc_UNKNOWN | Details |
thEnterParamMode | 151F | EnterParamMode | msrc_UNKNOWN | Details | |
thExitParamMode | 1520 | ExitParamMode | msrc_UNKNOWN | Details | |
thEnterGasConfig | 1539 | EnterGasConfig | msrc_UNKNOWN | Details | |
thExitGasConfig | 153A | ExitGasConfig | msrc_UNKNOWN | Details | |
thRestoreMeasMode | 1537 | RestoreMeasMode | Puts the Polytron2 back into measurement Mode. Useful if the device has been abandoned in any special mode. | msrc_UNKNOWN | Details |
th_onInfo | 1413 | Online Info | msrc_UNKNOWN | Details | |
mMasterReset | 1414 | Master Reset | Master Reset - Performs a master reset of the field device. Equivalent to cycling the transmitter power supply | msrc_UNKNOWN | Details |
th_reset | 1415 | Master Reset | Master Reset - Performs a master reset of the field device. Equivalent to cycling the transmitter power supply | msrc_UNKNOWN | Details |
thAdd1988 | 14AB | msrc_UNKNOWN | Details | ||
thSub1988 | 14AC | msrc_UNKNOWN | Details | ||
th_maintPswd | 1439 | Set Maint Password | Sets the Polytron Maintenance Password | msrc_UNKNOWN | Details |
th_cfgPswd | 143A | Set Config Password | Sets the Polytron Configuration Password | msrc_UNKNOWN | Details |
th_enableWarning | 143F | Warning Enabled | Deactivate Analog Warning signal | msrc_UNKNOWN | Details |
th_disableWarning | 1440 | Warning Disabled | Activate Analog Warning signal | msrc_UNKNOWN | Details |
th_mdropWarning | 1441 | N/A! Multidrop | Device is in Mutidrop; Analog Warning Signal is NOT Applicable | msrc_UNKNOWN | Details |
th_fixed | 1447 | Set to Fixed mA | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
th_reading | 1449 | Set to Gas Reading | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
th_special | 144A | Set Special Signal | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_cmd_180_mode | 1448 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
th_init01 | 14AE | Init to Factory | Initialize to factory settings | msrc_UNKNOWN | Details |
return_from_restore | 1451 | Aborting return to normal | msrc_UNKNOWN | Details | |
th_cal_sensor | 1461 | Calibrate Sensor | Calibrate Zero and Span.(Zero first) | msrc_UNKNOWN | Details |
am_exit_calc_md | 1469 | AbortMethod Exit Calcs | Exiting from Calibration Calculation mode | msrc_UNKNOWN | Details |
amRestoreMeasDB | 1462 | AbortMethod Exit Cal Db | Exiting from Calibration Database mode | msrc_UNKNOWN | Details |
amRemoveTestGas | 151D | msrc_UNKNOWN | Details | ||
am_exit_cal_mode | 1463 | AbortMethod Exit Cal Db | Exiting from Calibration Database mode | msrc_UNKNOWN | Details |
th_fundInit | 146B | Fundamental Init | WARNING! FACTORY USE ONLY! For restoring a corrupted DB ONLY. Erases current loop calibration! | msrc_UNKNOWN | Details |
th_stdInit | 146D | Standard Init | WARNING! FACTORY USE ONLY! Initializes DB (after a SW-Update). | msrc_UNKNOWN | Details |
th_stHistory | 1481 | Status History | msrc_UNKNOWN | Details | |
th_measGas | 148A | Select Gas/Unit | Selects the Measurement Gas and Unit | msrc_UNKNOWN | Details |
exit_gas_select | 148B | ExitGasSelect | Exiting from Gas Selection (selection mode not active) | msrc_UNKNOWN | Details |
th_calGas | 1494 | Cal Gas | Set Calibration Gas and Unit | msrc_UNKNOWN | Details |
exit_cal_select | 1495 | ExitCalGasSelect | Exiting from Cal Gas Selection (selection mode not active) | msrc_UNKNOWN | Details |
exit_reloadDB | 148F | ExitReloadDB | Exiting from Cal Gas Selection (Reload DB) | msrc_UNKNOWN | Details |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
dac_trim | 1004 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |