Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
do_reset_distribution_map | 4020 | reset distribution map | msrc_UNKNOWN | Details | |
do_auto_tuning_0 | 4029 | start auto-tuning of 'Do All' | msrc_UNKNOWN | Details | |
do_auto_tuning_1 | 402A | start auto-tuning of 'Do Level 1 only' | msrc_UNKNOWN | Details | |
do_auto_tuning_2 | 402B | start auto-tuning of 'Do Level 2 only' | msrc_UNKNOWN | Details | |
do_auto_tuning_3 | 402C | start auto-tuning of 'Do Level 3 only' | msrc_UNKNOWN | Details | |
do_stop_self_motion | 402D | stop self moving (finish with error code) | msrc_UNKNOWN | Details | |
do_read_tuned_parameters | 402E | re-read updated parameters after auto-tuning finished | msrc_UNKNOWN | Details | |
do_display_esc | 4030 | LCD display back (push ESC key once) | msrc_UNKNOWN | Details | |
do_calibrate_zero_range | 4050 | set current position as zero | msrc_UNKNOWN | Details | |
do_calibrate_span_range | 4051 | set current position as span | msrc_UNKNOWN | Details | |
do_calibrate_span_relative | 4052 | calibrate position's span by rate | msrc_UNKNOWN | Details | |
fill_umap_by_default | 407D | Other default curves | msrc_UNKNOWN | Details | |
do_calibrate_4mA | 409F | set current input as 4mA | msrc_UNKNOWN | Details | |
do_calibrate_20mA | 40A0 | set current input as 20mA | msrc_UNKNOWN | Details | |
do_reset_shut_cycle | 40AA | reset shutdown cycle counter | msrc_UNKNOWN | Details | |
do_reset_alarm_time | 40B5 | reset alarm timer | msrc_UNKNOWN | Details | |
do_reset_stroke_alarm | 40C4 | reset stroke alarm counter | msrc_UNKNOWN | Details | |
do_reset_trip_alarm | 40CE | reset trip alarm meter | msrc_UNKNOWN | Details | |
do_self_test | 40E8 | start self test pattern | msrc_UNKNOWN | Details | |
do_read_all_parameters | 40F4 | re-read all device specific parameters | msrc_UNKNOWN | Details | |
do_set_permanent | 4101 | Lock other users | msrc_UNKNOWN | Details | |
do_set_lock_all | 4102 | Lock all users | msrc_UNKNOWN | Details | |
do_unlock | 4103 | Unlock | msrc_UNKNOWN | Details | |
do_reset_more_status | 40FF | Reset more status flags | msrc_UNKNOWN | Details | |
do_reset_config_change | 4100 | Reset configuration change flag | msrc_UNKNOWN | Details | |
device_self_test | 1071 | Self test | Self Test- Commands the electronics to perform a self test. | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Device Reset- Commands the electronics to perform a reset. This is equivalent to cycling the power off and then back on to the field device. | msrc_UNKNOWN | Details |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
valve_loop_test | 1026 | Loop test | Loop test- Allows the User to use an external analog input signal at a constant value to test the Analog Input Channel, e.g. valves | msrc_UNKNOWN | Details |
lock_unlock_device | 1073 | Lock/Unlock device | Lock/Unlock Device- Places the device in either a locked or unlocked position. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |