0 |
SC150 |
1 |
.3f |
2 |
8.3f |
3 |
7d |
4 |
st_rev |
5 |
Target Mode |
6 |
Set mode to OOS to be able to read & write parameters. If mode is set to AUTO parameters can be read only |
7 |
OOS |
8 |
Auto |
9 |
Meas |
10 |
Conductivity |
11 |
Resisitivity |
12 |
PV |
13 |
.1f |
14 |
.0f |
15 |
.2f |
16 |
.4f |
17 |
.3g |
18 |
PV.range_units |
19 |
°C |
20 |
°F |
21 |
/min |
22 |
S |
23 |
mS |
24 |
O.m |
25 |
O.cm |
26 |
S/m |
27 |
mS/cm |
28 |
ppb |
29 |
ppt |
30 |
mV/pH |
31 |
spare2 |
32 |
spare3 |
33 |
rH |
34 |
%/°C |
35 |
%/°F |
36 |
mV/°C |
37 |
pH/°C |
38 |
pH/°F |
39 |
S/cm |
40 |
/m |
41 |
/cm |
42 |
Adj CC |
43 |
SV |
44 |
Temp unit |
45 |
Temp comp |
46 |
Manual |
47 |
Man value |
48 |
Temp sensor |
49 |
Pt1000 |
50 |
Pt100 |
51 |
Ni100 |
52 |
8k55 |
53 |
Pb36 (JIS6k) |
54 |
Sensor type |
55 |
2-elec |
56 |
4-elec |
57 |
Ohms |
58 |
TC SC1 |
59 |
Meas unit |
60 |
.m |
61 |
.cm |
62 |
Measure |
63 |
Cond only |
64 |
Cond+Conc |
65 |
Conc only |
66 |
Res only |
67 |
Method SC1 |
68 |
None |
69 |
TC |
70 |
NaCl |
71 |
Matrix |
72 |
Matrix SC1 |
73 |
Ammonia 0-50 ppb |
74 |
Morpholine 0-500 ppb |
75 |
Ammonia 15-30 % |
76 |
H2SO4 0-27 % |
77 |
H2SO4 39-85 % |
78 |
H2SO4 93-100 % |
79 |
NaOH 0-15 % |
80 |
NaOH 25-50 % |
81 |
HCl 0-200 ppb |
82 |
HCL 0-18 % |
83 |
HCL 24-44 % |
84 |
HNO3 0-25 % |
85 |
HNO3 35-80 % |
86 |
User defined 1 |
87 |
User defined 2 |
88 |
Additional table |
89 |
Disable |
90 |
Enable |
91 |
Conc table unit |
92 |
% |
93 |
ppm |
94 |
TV |
95 |
Method SC2 |
96 |
TC SC2 |
97 |
Matrix SC2 |
98 |
USP% |
99 |
USP safety margin |
100 |
Pol% |
101 |
Ref temp |
102 |
Cond too high |
103 |
Res too low |
104 |
Off |
105 |
Warn |
106 |
Fail |
107 |
Cond too low |
108 |
Res too high |
109 |
Temp too high |
110 |
Temp too low |
111 |
Pol detected |
112 |
USP23 detect |
113 |
Conc table |
114 |
2nd comp mtrx |
115 |
1st comp mtrx |
116 |
Cal time exc |
117 |
Cal interval |
118 |
Stab time |
119 |
Start air adjust |
120 |
Idle |
121 |
Start |
122 |
Succeeded |
123 |
Failed |
124 |
Air adjust offset |
125 |
Air adjust limit |
126 |
Fact CC |
127 |
CC hi lim. |
128 |
CC lo lim. |
129 |
SC hi lim |
130 |
Res lo lim |
131 |
SC lo lim |
132 |
Res hi lim |
133 |
SV.range_units |
134 |
TV.range_units |
135 |
Output Target mode |
136 |
Actual mode |
137 |
HOLD 0/1 |
138 |
disabled |
139 |
enabled |
140 |
HOLD L/F |
141 |
last |
142 |
fixed |
143 |
HOLD during cal |
144 |
Year |
145 |
02d |
146 |
Month |
147 |
Day |
148 |
Hour |
149 |
Minute |
150 |
Second |
151 |
PID Dir |
152 |
direct |
153 |
reverse |
154 |
Status |
155 |
Oos |
156 |
Hold |
157 |
Underflow |
158 |
Overflow |
159 |
Route1_error |
160 |
Route2_error |
161 |
Calc_error |
162 |
Expire_error |
163 |
Soft fail |
164 |
Hard fail |
165 |
Simulate |
166 |
Type |
167 |
Control |
168 |
Alarm |
169 |
HOLD |
170 |
Func |
171 |
P |
172 |
PI |
173 |
PID |
174 |
Wash |
175 |
Hard + Soft Fail |
176 |
On/Off |
177 |
Percentage |
178 |
Hard Fail only |
179 |
HOLD contact |
180 |
Alarm SP |
181 |
Alarm dir. |
182 |
low |
183 |
high |
184 |
Alarm hyst. |
185 |
Alarm delay |
186 |
PID SP |
187 |
PID Rng |
188 |
PID MR |
189 |
PID I time |
190 |
PID D time |
191 |
Contact |
192 |
On |
193 |
Analog output |
194 |
DC |
195 |
PF |
196 |
DC time |
197 |
Max freq |
198 |
Expire time |
199 |
S1 perc |
200 |
C1.unit |
201 |
> |
202 |
Select process parameter for this output. Valid parameters are: CONDUCT,CONDUCT2 and TEMPERATURE. |
203 |
Select process parameter for this output. Valid parameters are: CONDUCT,CONCENT and TEMPERATURE. |
204 |
Select process parameter for this output. Valid parameters are: RESIST1,RESIST2 and TEMPERATURE. |
205 |
Select process parameter for this output. Valid parameters are: CONCENT1,CONCENT2 and TEMPERATURE. |
206 |
S2 perc |
207 |
C2.unit |
208 |
Table_error |
209 |
Burn low |
210 |
Burn high |
211 |
Output |
212 |
Linear |
213 |
Table |
214 |
Damping time |
215 |
mA1 fixed |
216 |
Burn |
217 |
Low |
218 |
High |
219 |
Lin 0% |
220 |
Lin 100% |
221 |
mA1 perc |
222 |
mA1 value |
223 |
M1.unit |
224 |
mA2 fixed |
225 |
mA2 perc |
226 |
mA2 value |
227 |
M2.unit |
228 |
Input contact |
229 |
Disabled |
230 |
Factor 10 mA1 |
231 |
Factor 10 mA2 |
232 |
Factor 10 mA1+2 |
233 |
DD Rev. |
234 |
Software Rev. |
235 |
Device id. |
236 |
Tag |
237 |
Most appl. error |
238 |
Hold Instrument |
239 |
Hold Outputs |
240 |
Hold Off |
241 |
Select Hold function for the instrument. Set HOLD to INSTRUMENT to be able to change all parameters. Set HOLD to OUTPUTS to be able to change output parameters. |
242 |
Set date/time |
243 |
1pt CC Calibration |
244 |
Air Calibration |
245 |
Hot Key Menu |
246 |
Process values |
247 |
Zoom |
248 |
Zoom sensor |
249 |
Zoom outputs |
250 |
Zoom device |
251 |
Commissioning |
252 |
Measurement setup |
253 |
Configure sensor |
254 |
Temp settings |
255 |
Temp compensation |
256 |
Calibration |
257 |
Concentration |
258 |
Output setup |
259 |
Inp. contact setup |
260 |
mA1 setup |
261 |
mA2 setup |
262 |
S1 setup |
263 |
S2 setup |
264 |
HOLD setup |
265 |
Error config |
266 |
Write variables |
267 |
Undefined |
268 |
Parameter too large |
269 |
Parameter too small |
270 |
In write protect mode |
271 |
Invalid unit code |
272 |
Span too small |
273 |
Device is busy |
274 |
Command not implemented |
275 |
FMU860 |
276 |
DT |
277 |
DVC |
278 |
FCX |
279 |
AS800 |
280 |
340T |
281 |
340C |
282 |
344 |
283 |
Siemens Micro K |
284 |
SITRANS L |
285 |
SIPAN PH |
286 |
SITRANS P |
287 |
75SMT |
288 |
UNIDELTA |
289 |
8320 |
290 |
SX5100 |
291 |
TSV175 |
292 |
DMU |
293 |
3780 |
294 |
BM70 |
295 |
8u |
296 |
Set Hold ? |
297 |
Hold Instrument;Hold Outputs;Hold Off |
298 |
NO ERRORS |
299 |
PROGRAMMED DATA LOST
Remedy: Contact your local Yokogawa sales office. |
300 |
CHECKSUM ERROR
Remedy: Contact your local Yokogawa sales office. |
301 |
INITIALIZATION ERROR
Remedy: Contact your local Yokogawa sales office. |
302 |
MEASUREMENT NOT WORKING
Remedy: Go to HOLD menu and set HOLD to OFF or OUTPUTS. |
303 |
CONDUCTIVITY TOO HIGH
Remedy: Check con- nections and cable. Replace sensor. Adjust limits in: Error configuration |
304 |
CONDUCTIVITY TOO LOW
Remedy: Check con- nections and cable. Replace sensor. Adjust limits in: Error configuration |
305 |
TEMPERATURE TOO HIGH
Remedy: Check process temperature. Check selected sensortype. Check connections and cable. |
306 |
TEMPERATURE TOO LOW
Remedy: Check process temperature. Check selected sensortype. Check connections and cable. |
307 |
POLARIZATION DETECTED
Remedy: Clean or replace sensor.
Adjust process. |
308 |
USP LIMIT EXCEEDED
Remedy: Check ion exchangers. |
309 |
USP MARGIN EXCEEDED
Remedy: Check ion exchangers. |
310 |
ERROR IN CONC. TABLE
Remedy: Execute 'Check values' in: Commissioning » Meas. setup » Concentr. » Define table. |
311 |
ERROR IN 2ND MATRIX
Remedy: Execute 'Check values' in: Commissioning » Meas. setup » Temp. comp. » Matrix. |
312 |
ERROR IN 1ST MATRIX
Remedy: Execute 'Check values' in: Commissioning » Meas. setup » Temp. comp. » Matrix. |
313 |
CALIBRATION SCHEDULED
Remedy: Perform maintenance.
Reset interval. |
314 |
TC ERROR (SC1)
Remedy: Check temp. compensation config. in: Commissioning » Meas. setup » Temp. comp. |
315 |
TC ERROR (SC2)
Remedy: Check temp. compensation config. in: Commissioning » Meas. setup » Temp. comp. (method2) |
316 |
MA UNDERFLOW
Remedy:
Check process.
Adapt 0% value.
Adapt setpnt./range. |
317 |
MA OVERFLOW
Remedy:
Check process.
Adapt 100% value.
Adapt setpnt./range. |
318 |
MA ROUTING ERROR
Remedy: Select a correct process parameter in the setup menu. |
319 |
MA ROUTING ERROR
Remedy: Contact your local Yokogawa sales office. |
320 |
MA CALCULATION ERROR
Remedy: Check process parameter for mA output. |
321 |
ERROR IN MA TABLE
Remedy: Read the message in the table setup menu. |
322 |
MA BURN LOW
Remedy: Check measured process values. |
323 |
MA BURN HIGH
Remedy: Check measured process values. |
324 |
SIMULATED MA VALUE
Remedy: Re-configure in setup. |
325 |
CONTACT UNDERFLOW
Remedy:
Check process.
Adapt setpnt./range. |
326 |
CONTACT OVERFLOW
Remedy:
Check process.
Adapt setpnt./range. |
327 |
CONTACT ROUTING ERROR
Remedy: Select a correct process parameter in the setup menu. |
328 |
CONTACT ROUTING ERROR
Remedy: Contact your local Yokogawa sales office. |
329 |
CALCULATION ERROR
Remedy: Check process parameter for contacts. |
330 |
EXPIRY TIME EXCEEDED
Remedy: Check control equipment.
Adjust timer value in setup. |
331 |
Reset expiry time error? |
332 |
None;Only S1;Only S2;Both S1 and S2 |
333 |
? |
334 |
SOFT FAIL
Remedy: Check measured process values. |
335 |
HARD FAIL
Remedy: Check measured process values. |
336 |
SIMULATED CONTACT
Remedy: Re-configure in setup. |
337 |
OUTPUTS IN HOLD
Remedy: Press HOLD flag in main display. |
338 |
UNKNOWN ERROR-CODE
Error-code = %{0} |
339 |
Input day |
340 |
Input month |
341 |
Input year |
342 |
Input hour |
343 |
Input minute |
344 |
Input second |
345 |
Change date/time
%{0}/%{1}/%{2} %{3}:%{4}:%{5} |
346 |
%[.3g]{local_pv} %{5} ,
%[.1f]{0} %{1}
Enter new value |
347 |
CC out of limits |
348 |
New CC: %[.2f]{local_new_cc} %{2}
Accept ? |
349 |
Remove sensor from solution.
Offset = %{0} S
Adjust ? |
350 |
Air calibration busy.
PLEASE WAIT ... |
351 |
Air calibration succeeded.
Offset = %{0} S
|
352 |
Air calibration failed. Is sensor taken from solution?
Try again? |