0 |
PH150 |
1 |
.3f |
2 |
8.3f |
3 |
7d |
4 |
st_rev |
5 |
Sensor Target Mode |
6 |
Set mode to OOS to be able to read & write parameters. If mode is set to AUTO parameters can be read only |
7 |
OOS |
8 |
Auto |
9 |
PV |
10 |
.1f |
11 |
.0f |
12 |
.2f |
13 |
.3g |
14 |
PV.range_units |
15 |
°C |
16 |
°F |
17 |
p/m |
18 |
S |
19 |
mS |
20 |
O.m |
21 |
O.cm |
22 |
S/m |
23 |
mS/cm |
24 |
ppb |
25 |
ppt |
26 |
mV/pH |
27 |
spare2 |
28 |
spare3 |
29 |
rH |
30 |
%/°C |
31 |
%/°F |
32 |
mV/°C |
33 |
pH/°C |
34 |
pH/°F |
35 |
S/cm |
36 |
/m |
37 |
/cm |
38 |
mV/°F |
39 |
Sensor Type |
40 |
pH |
41 |
ORP |
42 |
pH+ORP |
43 |
Sensor mV |
44 |
Slope |
45 |
Slope unit |
46 |
Zero |
47 |
Zero unit |
48 |
ITP |
49 |
SV |
50 |
Temp unit |
51 |
Temp comp |
52 |
Manual |
53 |
Man value |
54 |
Temp sensor |
55 |
Pt1000 |
56 |
Pt100 |
57 |
5k1 |
58 |
3kBalco |
59 |
8k55 |
60 |
350 |
61 |
NTC10k |
62 |
6k8 |
63 |
Connection temp |
64 |
Ref temp |
65 |
Zero hi lim |
66 |
Zero lo lim |
67 |
Slope hi lim |
68 |
Slope lo lim |
69 |
Stab time |
70 |
Comp method |
71 |
None |
72 |
TC |
73 |
Matrix |
74 |
NEN 6411 |
75 |
Ref imp |
76 |
Ref imp hi lim |
77 |
Ref imp lo lim |
78 |
pH too high |
79 |
Off |
80 |
Warn |
81 |
Fail |
82 |
pH too low |
83 |
Temp too high |
84 |
Temp too low |
85 |
ORP too high |
86 |
ORP too low |
87 |
rH too high |
88 |
rH too low |
89 |
Glass imp low |
90 |
Ref imp high |
91 |
Ref imp low |
92 |
Pt imp too low |
93 |
Matrix config |
94 |
Cal time exc. |
95 |
Cal int |
96 |
Meas type |
97 |
pH+rH |
98 |
TV.range_units |
99 |
ORP zero |
100 |
ORP comp method |
101 |
ORP TC |
102 |
TV |
103 |
ORP sensor mV |
104 |
Pt imp |
105 |
ORP zero hi lim |
106 |
ORP zero lo lim |
107 |
ORP slope |
108 |
ORP slope hi lim |
109 |
ORP slope lo lim |
110 |
Buffer set |
111 |
Nist |
112 |
DIN |
113 |
US |
114 |
User defined |
115 |
Output Target mode |
116 |
Actual mode |
117 |
HOLD 0/1 |
118 |
disabled |
119 |
enabled |
120 |
HOLD L/F |
121 |
last |
122 |
fixed |
123 |
HOLD during cal |
124 |
Year |
125 |
02d |
126 |
Month |
127 |
Day |
128 |
Hour |
129 |
Minute |
130 |
Second |
131 |
PID Dir |
132 |
direct |
133 |
reverse |
134 |
Status |
135 |
Oos |
136 |
Hold |
137 |
Underflow |
138 |
Overflow |
139 |
Route1_error |
140 |
Route2_error |
141 |
Calc_error |
142 |
Expire_error |
143 |
Soft fail |
144 |
Hard fail |
145 |
Simulate |
146 |
Type |
147 |
Control |
148 |
Alarm |
149 |
HOLD |
150 |
Func |
151 |
P |
152 |
PI |
153 |
PID |
154 |
Wash |
155 |
Hard + Soft Fail |
156 |
On/Off |
157 |
Percentage |
158 |
Hard Fail only |
159 |
HOLD contact |
160 |
Alarm SP |
161 |
Alarm dir. |
162 |
low |
163 |
high |
164 |
Alarm hyst. |
165 |
Alarm delay |
166 |
PID SP |
167 |
PID Rng |
168 |
PID MR |
169 |
PID I time |
170 |
PID D time |
171 |
Contact |
172 |
On |
173 |
Analog output |
174 |
DC |
175 |
PF |
176 |
DC time |
177 |
Max freq |
178 |
Expire time |
179 |
S1 perc |
180 |
C1.unit |
181 |
> |
182 |
Select process parameter for this output. Valid parameters are: PH and TEMPERATURE. |
183 |
Select process parameter for this output. Valid parameters are: ORP and TEMPERATURE. |
184 |
Select process parameter for this output. Valid parameters are: PH, ORP and TEMPERATURE. |
185 |
Select process parameter for this output. Valid parameters are: PH, RH and TEMPERATURE. |
186 |
Select process parameter for this output. Valid parameters are: RH and TEMPERATURE. |
187 |
S2 perc |
188 |
C2.unit |
189 |
Table_error |
190 |
Burn low |
191 |
Burn high |
192 |
Output |
193 |
Linear |
194 |
Table |
195 |
Damping time |
196 |
mA1 fixed |
197 |
Burn |
198 |
Low |
199 |
High |
200 |
Lin 0% |
201 |
Lin 100% |
202 |
mA1 perc |
203 |
mA1 value |
204 |
M1.unit |
205 |
mA2 fixed |
206 |
mA2 perc |
207 |
mA2 value |
208 |
M2.unit |
209 |
DD Rev. |
210 |
Software Rev. |
211 |
Device id. |
212 |
Tag |
213 |
Most appl. error |
214 |
Hold Instrument |
215 |
Hold Outputs |
216 |
Hold Off |
217 |
Select Hold function for the instrument. Set HOLD to INSTRUMENT to be able to change all parameters. Set HOLD to OUTPUTS to be able to change output parameters. |
218 |
Set date/time |
219 |
1pt pH Calibration |
220 |
Hot Key Menu |
221 |
Process values |
222 |
Zoom |
223 |
Zoom sensor |
224 |
Zoom outputs |
225 |
Zoom device |
226 |
Commissioning |
227 |
Sensor setup |
228 |
Measurement setup |
229 |
Temp settings |
230 |
Temp compensation |
231 |
Calibration |
232 |
Zero/Slope units |
233 |
************ |
234 |
Limits and timing |
235 |
Zero/Slope/ITP |
236 |
Zero/Slope |
237 |
Impedance settings |
238 |
Output setup |
239 |
mA1 setup |
240 |
mA2 setup |
241 |
S1 setup |
242 |
S2 setup |
243 |
HOLD setup |
244 |
Error config |
245 |
Write variables |
246 |
Undefined |
247 |
Parameter too large |
248 |
Parameter too small |
249 |
In write protect mode |
250 |
Invalid unit code |
251 |
Span too small |
252 |
Device is busy |
253 |
Command not implemented |
254 |
FMU860 |
255 |
DT |
256 |
DVC |
257 |
FCX |
258 |
AS800 |
259 |
340T |
260 |
340C |
261 |
344 |
262 |
Siemens Micro K |
263 |
SITRANS L |
264 |
SIPAN PH |
265 |
SITRANS P |
266 |
75SMT |
267 |
UNIDELTA |
268 |
8320 |
269 |
SX5100 |
270 |
TSV175 |
271 |
DMU |
272 |
3780 |
273 |
BM70 |
274 |
8u |
275 |
Set Hold ? |
276 |
Hold Instrument;Hold Outputs;Hold Off |
277 |
NO ERRORS |
278 |
PROGRAMMED DATA LOST
Remedy: Contact your local Yokogawa sales office. |
279 |
CHECKSUM ERROR
Remedy: Contact your local Yokogawa sales office. |
280 |
INITIALIZATION ERROR
Remedy: Contact your local Yokogawa sales office. |
281 |
MEASUREMENT NOT WORKING
Remedy: Go to HOLD menu and set HOLD to OFF or OUTPUTS. |
282 |
PH TOO HIGH
Remedy: Check connections and cable.
Replace sensor. |
283 |
PH TOO LOW
Remedy: Check connections and cable.
Replace sensor. |
284 |
TEMPERATURE TOO HIGH
Remedy: Check process temperature. Check selected sensortype. Check connections and cable. |
285 |
TEMPERATURE TOO LOW
Remedy: Check process temperature. Check selected sensortype. Check connections and cable. |
286 |
ORP TOO HIGH
Remedy: Check con- nections and cable.
Replace sensor. |
287 |
ORP TOO LOW
Remedy: Check con- nections and cable.
Replace sensor. |
288 |
RH TOO HIGH
Remedy: Check con- nections and cable.
Replace sensor. |
289 |
RH TOO LOW
Remedy: Check con- nections and cable.
Replace sensor. |
290 |
GLASS IMP. TOO LOW
Remedy: Replace measuring sensor.
Replace or dry cables. |
291 |
REF. IMP. TOO HIGH
Remedy: Clean or replace sensor.
Check sensor immer- sion. Check electro- lyte reservoir. |
292 |
REF. IMP. TOO LOW
Remedy: Replace reference sensor.
Check cables. |
293 |
ORP IMP. TOO HIGH
Remedy: Check con- nections.
Replace sensor. |
294 |
GLASS IMP. 2 TOO LOW
Remedy: Replace measuring sensor.
Replace or dry cables. |
295 |
MELZER SLOPE ERROR
Remedy: Contact your local Yokogawa sales office. |
296 |
TC MATRIX ERROR
Remedy: Read the message in the temperature compen- sation setup menu and adjust the values. |
297 |
CALIBRATION SCHEDULED
Remedy: Perform maintenance.
Reset interval. |
298 |
TC ERROR (PH)
Remedy: Check pH temperature compen- sation configuration in setup. |
299 |
TC ERROR (ORP)
Remedy: Check ORP temperature compen- sation configuration in setup. |
300 |
LOGBOOK (ALMOST) FULL
Remedy: Save or erase logbooks.
Turn logbook warning off. |
301 |
MA UNDERFLOW
Remedy:
Check process.
Adapt 0% value.
Adapt setpnt./range. |
302 |
MA OVERFLOW
Remedy:
Check process.
Adapt 100% value.
Adapt setpnt./range. |
303 |
MA ROUTING ERROR
Remedy: Select a correct process parameter in the setup menu. |
304 |
MA ROUTING ERROR
Remedy: Contact your local Yokogawa sales office. |
305 |
MA CALCULATION ERROR
Remedy: Check process parameter for mA output. |
306 |
ERROR IN MA TABLE
Remedy: Read the message in the table setup menu. |
307 |
MA BURN LOW
Remedy: Check measured process values. |
308 |
MA BURN HIGH
Remedy: Check measured process values. |
309 |
SIMULATED MA VALUE
Remedy: Re-configure in setup. |
310 |
EXPIRY TIME EXCEEDED
Remedy: Check control equipment.
Adjust timer value in setup. |
311 |
Reset expiry time error? |
312 |
None;Only mA1;Only mA2;Both mA1 and mA2 |
313 |
? |
314 |
CONTACT UNDERFLOW
Remedy:
Check process.
Adapt setpnt./range. |
315 |
CONTACT OVERFLOW
Remedy:
Check process.
Adapt setpnt./range. |
316 |
CONTACT ROUTING ERROR
Remedy: Select a correct process parameter in the setup menu. |
317 |
CONTACT ROUTING ERROR
Remedy: Contact your local Yokogawa sales office. |
318 |
CALCULATION ERROR
Remedy: Check process parameter for contacts. |
319 |
None;Only S1;Only S2;Both S1 and S2 |
320 |
SOFT FAIL
Remedy: Check measured process values. |
321 |
HARD FAIL
Remedy: Check measured process values. |
322 |
SIMULATED CONTACT
Remedy: Re-configure in setup. |
323 |
OUTPUTS IN HOLD
Remedy: Press HOLD flag in main display. |
324 |
UNKNOWN ERROR-CODE
Error-code = %{0} |
325 |
Input day |
326 |
Input month |
327 |
Input year |
328 |
Input hour |
329 |
Input minute |
330 |
Input second |
331 |
Change date/time
%{0}/%{1}/%{2} %{3}:%{4}:%{5} |
332 |
%[.2f]{local_ph} pH , %[.1f]{0} %{1}
Enter new pH value |
333 |
Zero out of limits |
334 |
New zero: %[.2f]{local_new_offset} %{2}
Accept ? |