0 |
ADMAG AE |
1 |
Error |
2 |
uP fault |
3 |
EEPROM fault |
4 |
A/D(L) fault |
5 |
A/D(H) fault |
6 |
Signal overflow |
7 |
Coil open |
8 |
Vel.span>10m/s |
9 |
Vel.span<0.3m/s |
10 |
P.span>1000p/s |
11 |
P.span>500p/s |
12 |
P.span>25p/s |
13 |
P.span>15p/s |
14 |
P.span>10p/s |
15 |
P.span>5p/s |
16 |
P.span<.0001p/s |
17 |
T.span>1000p/s |
18 |
T.span<.0001p/s |
19 |
4-20 lmt error |
20 |
Empty pipe |
21 |
Multi range error |
22 |
Device id not entered |
23 |
Reverse total |
24 |
differecial total |
25 |
Flow Sensor- Hardware that measures flow rate. |
26 |
.0f |
27 |
.1f |
28 |
.2f |
29 |
.3f |
30 |
.4f |
31 |
.3g |
32 |
6.3f |
33 |
Dummy float value |
34 |
g |
35 |
Dummy Integer3 Value |
36 |
8d |
37 |
Dummy transfer function |
38 |
Span |
39 |
6g |
40 |
5.1f |
41 |
Total units |
42 |
Total units- Engineering units that the frequency and totalizer outputs will be displayed with |
43 |
Total Value- Total of forward flow value. |
44 |
6.0f |
45 |
Reverse total units |
46 |
Reverse total units- Engineering units that the reverse total will be displayed with |
47 |
Reverse total Value- Total of reverse flow value. |
48 |
Dif. total |
49 |
Differencial total units |
50 |
Differential total units- Engineering units that the differential total will be displayed with |
51 |
Differential total Value- Difference between total and reverse total. |
52 |
Dif total units |
53 |
Dif total |
54 |
Size unit |
55 |
Line size |
56 |
6.1f |
57 |
Base vol unit |
58 |
k Cum |
59 |
Cucm |
60 |
M gal |
61 |
k gal |
62 |
m gal |
63 |
k bbl |
64 |
m bbl |
65 |
u bbl |
66 |
Base time unit |
67 |
Low MF |
68 |
6.4f |
69 |
High MF |
70 |
Velocity check |
71 |
Total unit |
72 |
n UNIT/P |
73 |
u UNIT/P |
74 |
m UNIT/P |
75 |
UNIT/P |
76 |
k UNIT/P |
77 |
M UNIT/P |
78 |
PULSE/s |
79 |
Total scale |
80 |
Total low cut |
81 |
3d |
82 |
Total set |
83 |
Inhibit |
84 |
Enable |
85 |
Tl set value |
86 |
6d |
87 |
Total switch |
88 |
Analog low cut |
89 |
2d |
90 |
Analog low lmt |
91 |
3.0f |
92 |
Analog hi lmt |
93 |
4-20 alarm out |
94 |
2.4mA or less |
95 |
4.0mA |
96 |
Hold |
97 |
21.6mA or more |
98 |
Disp select |
99 |
Rate (%) |
100 |
Rate |
101 |
For.total |
102 |
Rev.total |
103 |
Dif.total |
104 |
Rate(%)/For.ttl |
105 |
Rate/For.ttl |
106 |
Rate(%)/Rate |
107 |
Rate(%)/Rev.ttl |
108 |
Rate/Rev.ttl |
109 |
Rate(%)/Dif.ttl |
110 |
Rate/Dif.ttl |
111 |
Fl user sel |
112 |
Not provided |
113 |
Provided |
114 |
Fl user span |
115 |
Status out |
116 |
Normal |
117 |
Closed (on) |
118 |
Open (off) |
119 |
Total/pulse |
120 |
No damp |
121 |
Damp |
122 |
Output mode |
123 |
On active |
124 |
Off active |
125 |
Rate limit |
126 |
Dead time |
127 |
Power synch |
128 |
Yes |
129 |
No |
130 |
Power freq |
131 |
5.2f |
132 |
Pulsing flow |
133 |
Alarm |
134 |
No alarm |
135 |
Zero tuning |
136 |
Flow dir |
137 |
Forward |
138 |
Reverse |
139 |
Output function |
140 |
Pulse out |
141 |
Alarm out |
142 |
Bi direction |
143 |
Auto 2 ranges |
144 |
Low alarm |
145 |
Pulse unit |
146 |
Pulse scale |
147 |
Pulse low cut |
148 |
Pulse width |
149 |
50% Duty |
150 |
0.5 msec |
151 |
1 msec |
152 |
20 msec |
153 |
33 msec |
154 |
50 msec |
155 |
100 msec |
156 |
Forward span2 |
157 |
Reverse span |
158 |
3.1d |
159 |
Auto range hys |
160 |
Bi direction hys |
161 |
Low alarm hys |
162 |
Span value |
163 |
Percent unit |
164 |
% |
165 |
%[F1] |
166 |
%[F2] |
167 |
%[F3] |
168 |
%[F4] |
169 |
%[R1] |
170 |
%[R2] |
171 |
%[R3] |
172 |
%[R4] |
173 |
PV display unit |
174 |
k Cum/d |
175 |
l/d |
176 |
Cucm/d |
177 |
k gal/d |
178 |
m gal/d |
179 |
k bbl/d |
180 |
m bbl/d |
181 |
u bbl/d |
182 |
conv/d |
183 |
k Cum/h |
184 |
Cucm/h |
185 |
M gal/h |
186 |
k gal/h |
187 |
m gal/h |
188 |
k bbl/h |
189 |
m bbl/h |
190 |
u bbl/h |
191 |
conv/h |
192 |
k Cum/min |
193 |
Cucm/min |
194 |
M gal/min |
195 |
k gal/min |
196 |
m gal/min |
197 |
k bbl/min |
198 |
m bbl/min |
199 |
u bbl/min |
200 |
conv/min |
201 |
k Cum/s |
202 |
Cucm/s |
203 |
M gal/s |
204 |
k gal/s |
205 |
m gal/s |
206 |
k bbl/s |
207 |
m bbl/s |
208 |
u bbl/s |
209 |
conv/s |
210 |
Span unit |
211 |
DISPLAY POINT |
212 |
ALARM SELECT |
213 |
Password |
214 |
New_password |
215 |
Software seal |
216 |
Break |
217 |
Keep |
218 |
Not Write Protect Mode |
219 |
Password Mismach |
220 |
The 1st sequence for Xmtr ( Mismatch sequence? ) |
221 |
Commands the ADMAG AE electronics to perform a selftest. Reports any errors that occured. |
222 |
Enable write |
223 |
New password |
224 |
remove menu |
225 |
Enable wrt 10min |
226 |
Aborting |
227 |
Exiting |
228 |
Status output test |
229 |
Preset forward totalizer |
230 |
Reset reverse totalizer |
231 |
Master reset |
232 |
Master Reset- Commands the electronics to reset and perform a self test. Reports any errors that occured. |
233 |
Offline |
234 |
Device setup |
235 |
process variables |
236 |
Diag/Service |
237 |
Test device |
238 |
Test/Status |
239 |
Status |
240 |
Output trim |
241 |
Basic setup |
242 |
Detailed setup |
243 |
Sensor |
244 |
Flow units |
245 |
Sensor info |
246 |
Sensor config |
247 |
Input |
248 |
Signal processing |
249 |
Totalizer |
250 |
Outputs |
251 |
Analog set |
252 |
Analog output |
253 |
HART output |
254 |
Function set |
255 |
Pulse output |
256 |
Disp output |
257 |
Appl set |
258 |
Device info |
259 |
Review |
260 |
Review 1 |
261 |
Review 2 |
262 |
Review 3 |
263 |
Wrt protect menu |
264 |
Write variables |
265 |
FMU860 |
266 |
DT |
267 |
DVC |
268 |
FCX |
269 |
AS800 |
270 |
340T |
271 |
340C |
272 |
344 |
273 |
Siemens Micro K |
274 |
SITRANS L |
275 |
SIPAN PH |
276 |
SITRANS P |
277 |
75SMT |
278 |
UNIDELTA |
279 |
8320 |
280 |
SX5100 |
281 |
TSV175 |
282 |
DMU |
283 |
3780 |
284 |
BM70 |
285 |
8u |
286 |
low |
287 |
high |
288 |
tmp_av |
289 |
Aborting method due to last error |
290 |
Device maybe stuck in selftest. |
291 |
Self test OK |
292 |
About to enter auto zero |
293 |
The previous error was seen while trying to initiate auto zero. |
294 |
Waiting for auto zero to complete. |
295 |
Auto zero passed |
296 |
Input password |
297 |
Write enable in 10 minutes |
298 |
Enter New Password |
299 |
Set New Password OK |
300 |
Re-Enter New Password |
301 |
Enter current password to enable to write for 10 minutes: |
302 |
Released the write protection for 10 minutes. |
303 |
If you wish to release completely, you have to change password to all of spaces. |
304 |
Enter new password to change state of write protect: |
305 |
Re-enter new password within 30 seconds: |
306 |
Changed to new password. |
307 |
It changed the state of protection related password. |
308 |
Choose status output test |
309 |
Closed(on);Open(off);End |
310 |
status output now set to Closed(on) |
311 |
status output now set to Open(off) |
312 |
Inhibits or enables auto zero |
313 |
Zero Tuning now set to %{0} |
314 |
Inhibits or enables forward total and reverse total from being preset and reset,respectively |
315 |
Total set now set to %{0} |
316 |
Sets forward total preset value |
317 |
Tl set value now set to %0 |
318 |
Sets an arbitrary preset value in 'forward total'.
Note:
For presetting a 'forward total' value to the value set in 'Tl set value', 'Enable' should be selected in 'Total set', and also 'Tl set value' can be set for an arbitrary value. |
319 |
Forward total now set to %0 |
320 |
About to preset. (Tl set value = %0 )
Note:
For setting an arbitrary value in 'forward total', 'Inhibit' should be selected in 'Total set'. |
321 |
Sets an arbitrary preset value in 'reverse total'.
Note:
For resetting zero in 'reverse total', 'Enable' should be selected in 'Total set'. |
322 |
Reverse total now set to %0 |
323 |
About to reset.
Note:
For setting an arbitrary value in 'reverse total', 'Inhibit' should be selected in 'Total set'. |
324 |
Reverse total now set to 0 |
325 |
Device maybe stuck in self test. |
326 |
Master reset OK |