0 |
ICOT |
1 |
SmartCal |
2 |
DEPIC |
3 |
DEPIC_ESD_PST |
4 |
Dev Alerts |
5 |
Cycle Alert |
6 |
Travel Accum Alert |
7 |
Travel Alert |
8 |
PST Cycle Alert |
9 |
PST SetPoint Alert |
10 |
PST Cyc Time Alert |
11 |
Esd alert |
12 |
Reserved alert |
13 |
Dev Errors |
14 |
Hi Cal error |
15 |
Low Cal error |
16 |
Span Cal error |
17 |
Sensor Cal error |
18 |
Reserved error |
19 |
Refers to the requested position in terms of percent. |
20 |
Op_Time |
21 |
.3f |
22 |
Refers to the actual valve position in terms of percent. |
23 |
Position |
24 |
3.1f |
25 |
Refers to the output close_time_data of OUT 1 of the DEPIC in terms of percent. |
26 |
close_time_data |
27 |
Op_time Units |
28 |
Position Units |
29 |
cl_time Units |
30 |
Sensor Units |
31 |
Refers to the requested position in terms of current in mA. |
32 |
Input I |
33 |
2.2f |
34 |
Refers to the actual valve position in terms of current in mA. |
35 |
Output I |
36 |
Refers to the input current to move the valve to full open / close position in normal / reverse operation. |
37 |
FS In |
38 |
Zero In |
39 |
Refers to the output current when the valve is at full open / close position in normal / reverse operation. |
40 |
FS Out |
41 |
Zero Out |
42 |
Sensor Serial |
43 |
Min_Sensor_Span |
44 |
|
45 |
mA Range |
46 |
Flow Type |
47 |
Sensor_Unit |
48 |
Min Span |
49 |
Cl_Time |
50 |
The DEPIC supports Linear, Quick Opening, and Equal Percentage flow types. |
51 |
Quick opening |
52 |
Flow characteristics is quick opening |
53 |
Equal percentage |
54 |
Flow characteristic is equal percentage |
55 |
CAL BUSY |
56 |
Busy reading limits. |
57 |
Disable |
58 |
Normal |
59 |
Cal_busy |
60 |
In Cal busy |
61 |
CAL START |
62 |
Cal started by hart |
63 |
Cal_start |
64 |
In Cal started |
65 |
CAL TERMINATE |
66 |
Calibration termination. |
67 |
Cal_terminate |
68 |
In Cal Terminate |
69 |
CAL FINISH |
70 |
Calibration finish. |
71 |
Cal_finish |
72 |
In Cal Finish |
73 |
CAL OPEN VALVE |
74 |
Open the valve to calibrate device. |
75 |
Start_open |
76 |
In Cal Open |
77 |
CAL CLOSE VALVE |
78 |
Close the valve to calibrate device. |
79 |
Normal |
80 |
Start_close |
81 |
In Cal Close |
82 |
HART CAL |
83 |
Start Cal using Hart Master. |
84 |
Start_cal |
85 |
Start Cal |
86 |
KEY STARTED CAL |
87 |
CAL is not avaiable. |
88 |
CAL Avaiable |
89 |
Key_cal |
90 |
CAL Not Avaiable |
91 |
PST_Err |
92 |
Success |
93 |
Success |
94 |
not_open |
95 |
Not Open |
96 |
brk_time |
97 |
Break Time |
98 |
exced_sp |
99 |
Excced SP |
100 |
cyc_time |
101 |
Cycle Time |
102 |
progress |
103 |
In Progress |
104 |
n_active |
105 |
Not Activated |
106 |
aborted |
107 |
Aborted |
108 |
Pst_Abort |
109 |
|
110 |
Never_activated |
111 |
Never ACT |
112 |
PST in_progress |
113 |
Pst_in_progress |
114 |
Pst Busy |
115 |
PST cycle time |
116 |
Cycle_time exceed limit |
117 |
Cycle_time |
118 |
PST exceed sp |
119 |
Setpoint exceed limit |
120 |
Exceed_sp |
121 |
PST break_time |
122 |
Valve exceed break time |
123 |
Break time |
124 |
PST CAN'T Perform |
125 |
Valve should open to do PST |
126 |
Jam Valve |
127 |
PST Finish |
128 |
PST finish without error |
129 |
Pst_abort |
130 |
Pst finish without error |
131 |
PST_Ctr |
132 |
pst can Enable and Disable . |
133 |
Enable |
134 |
ESD_Ctr |
135 |
ESD can Enable and Disable . |
136 |
Pst_set_point |
137 |
Set the limits for partial stroke |
138 |
50% |
139 |
PST 50% |
140 |
60% |
141 |
PST 60% |
142 |
65% |
143 |
PST 65% |
144 |
70% |
145 |
PST 70% |
146 |
75% |
147 |
PST 75% |
148 |
80% |
149 |
PST 80% |
150 |
85% |
151 |
PST 85% |
152 |
90% |
153 |
PST 90% |
154 |
95% |
155 |
PST 95% |
156 |
Pst_cyc_Lim |
157 |
Set the limits for partial stroke counts |
158 |
Cyc_time_Lim |
159 |
Set the limits for partial stroke cycle time |
160 |
.1f |
161 |
Control Mode |
162 |
Control the valve in either normal or reverse acting mode. |
163 |
Normal Acting Mode |
164 |
Reverse |
165 |
Reverse Acting Mode |
166 |
DisplayMode |
167 |
Show %closed or %open on DEPIC display. |
168 |
%Open |
169 |
Read percentage open |
170 |
%Close |
171 |
Read percentage close |
172 |
Valve Type |
173 |
DEPIC can work with linear and rotary valves. |
174 |
Linear |
175 |
Linear valve |
176 |
Rotary |
177 |
Rotary valve |
178 |
IFS is measured Full Scale Loop Current |
179 |
Max Current |
180 |
5.2f |
181 |
IMN is measured Minimum Loop Current |
182 |
Min Current |
183 |
1.2f |
184 |
4.2f |
185 |
Full scale A/D count |
186 |
Full scale A/D count returned by command 135 |
187 |
MIN scale A/D count |
188 |
Minimum scale A/D count returned by command 135 |
189 |
ESD Alert |
190 |
When enabled, the DEPIC will signal alert signal when ESD is activated. |
191 |
When enabled, the DEPIC will signal alert signal when PST cycle time limits is violated. |
192 |
Set point |
193 |
When enabled, the DEPIC will signal alert signal when PST Set point limits is violated. |
194 |
Cyc Count |
195 |
When enabled, the DEPIC will signal alert signal when PST cycle limits is violated. |
196 |
TravelAlrt |
197 |
When enabled, the DEPIC will signal alert signal when upper or lower travel limits is violated. |
198 |
CycleAlert |
199 |
When enabled, the DEPIC will signal alert signal when cycle limits is violated. |
200 |
AcumAlert |
201 |
When enabled, the DEPIC will signal alert signal when accumulator limits is violated. |
202 |
Travel High |
203 |
Denotes the upper travel limit of the valve before the travel alert is set. |
204 |
% |
205 |
5.1f |
206 |
Travel Low |
207 |
Denotes the lower travel limit of the valve before the travel alert is set. |
208 |
Travel DB |
209 |
Denotes the travel limit deadband of the valve. |
210 |
Cycle Count |
211 |
Denotes the cycle count of the valve. |
212 |
Cycle Limit |
213 |
Denotes the cycle limit of the valve before the cycle alert is set. |
214 |
Cycle DB |
215 |
Denotes the cycle deadband of the valve. |
216 |
Accum. Count |
217 |
Denotes the Accumulator count of the valve. |
218 |
Accum. Limit |
219 |
Denotes the accumulator limit of the valve before the accumulator alert is set. |
220 |
Accum. DB |
221 |
Denotes the accumulator deadband of the valve. |
222 |
SetPoint |
223 |
Partial Strock set point value. |
224 |
2.1f |
225 |
BreakTime |
226 |
Valve Break away time |
227 |
CycTime |
228 |
PST Cycle time |
229 |
CycCount |
230 |
PST Cycle Count |
231 |
write_variables |
232 |
Main Menu |
233 |
Partial Stroke |
234 |
Partial Stroke DATA |
235 |
Config |
236 |
Basic Config |
237 |
Alert Config |
238 |
Cycle Alert |
239 |
Acum Alert |
240 |
PST/ESD Alert |
241 |
Device Info |
242 |
Manufacturer |
243 |
Dev_Alert_Err |
244 |
Revision |
245 |
Restore RAM |
246 |
Abort_Calibration |
247 |
Restore Limit Control |
248 |
Calibration |
249 |
Start Pst |
250 |
FMU860 |
251 |
DT |
252 |
DVC |
253 |
FCX |
254 |
AS800 |
255 |
340T |
256 |
340C |
257 |
344 |
258 |
Siemens Micro K |
259 |
SITRANS L |
260 |
SIPAN PH |
261 |
SITRANS P |
262 |
75SMT |
263 |
UNIDELTA |
264 |
8320 |
265 |
SX5100 |
266 |
TSV175 |
267 |
DMU |
268 |
3780 |
269 |
BM70 |
270 |
8u |
271 |
Process Cancelled! |
272 |
Restore from EEPROM;Store in RAM;Burn into EEPROM |
273 |
Restore default settings from EEPROM |
274 |
Restore not successful |
275 |
New settings store in RAM only |
276 |
Burn the new settings into EEPROM |
277 |
Burn not successful |
278 |
Abort not Sucessful |
279 |
START CALIBRATION |
280 |
CLOSE VALVE |
281 |
OPEN VALVE |
282 |
CALIBRATION FINISH |
283 |
PST is Disable |
284 |
Start Partial Stoke |
285 |
BUSY Partial Stroke |
286 |
Exceed Cycle Time |
287 |
Exceed Break Time |
288 |
Exceed Setpoint |
289 |
Pst_not_open |
290 |
Finish Partial Stroke |
291 |
Partial Stroke Success |
292 |
ERROR |