Zero calibrate |
14 |
Zero calibrate - Make the sensor input the new zero input reference. Sensor gain trim point is not adjusted. |
15 |
sealed gauge |
16 |
vacuum |
17 |
Gain trim |
18 |
conventional |
19 |
coplanar |
20 |
remote seal |
21 |
half inch National Pipe Thread (NPT) |
22 |
YA MS33649-04 |
23 |
YB MS33649-04 (Square Flange/Side Port) |
24 |
YC MS33656-04 (37ø Flared) |
25 |
YD MS33656-06 (37ø Flared) |
26 |
YE MS33656-08 (37ø Flared) |
27 |
YF SAE J513F (45ø Flared) |
28 |
YG MS16142-04 |
29 |
YH 1/8 in NPT(M) |
30 |
YI 1/8 in NPT(F) |
31 |
YJ 1/4 in NPT(F) |
32 |
YK 1/4 in NPT(M) |
33 |
YL 1/4 in NPT(F) (Square Flange/Side Port) |
34 |
YM 1/4 in F250-C High Pressure Tube |
35 |
YN 3/8 in NPT(F) |
36 |
YP 1/2 in NPT(M) |
37 |
YQ 1/8 in NPT(F) (Square Flange/Side Port) |
38 |
YR 1/2 in NPT(F) |
39 |
YS 3/8 in F375-C High Pressure Tube |
40 |
YT MS33656-04 WITH 7/8 in HEX |
41 |
YU MS16142-06 |
42 |
YV MS33649-08 |
43 |
YW G-1/4 in (F) X74 w/Remote Seals |
44 |
YX G-1/4 in (M) w/o Fill Port |
45 |
YY G-1/4 in (M) w/Fill Port |
46 |
YZ G-1/2 in (M) w/Fill Port |
47 |
WA G-1/4 in (F) Industrial Test Flange X74 Reduced Volume |
48 |
WB 1/4 in NPT(F) Industrial Test Flange X74 Reduced Volume |
49 |
WC MS33656-06 w/o 37ø Flare |
50 |
WD G-1/2 in (F) Industrial Test Flange X71 Reduced Volume |
51 |
WE G-1/2 in (M) w/o Fill Port |
52 |
WF G-1/2 in (F) w/o Fill Port |
53 |
WG G-1/4 in (F) w/o Fill Port |
54 |
WH G-1/4 in (M) w/o Fill Port |
55 |
SA 1/4 in NPT(F) Pressure Port, Low Volume w/o Fill Port |
56 |
HA 1-1/2 in Tri-Clover Fitting |
57 |
HB 2 in Tri-Clover Fitting |
58 |
HC 2-1/2 in Tri-Clover Fitting |
59 |
HG 3 in Tri-Clover Fitting |
60 |
HH 1/2 in Tri-Clover Fitting |
61 |
SC 4 in Tri-Clover Fitting |
62 |
LA 4 in 150 Lb. ANSI Flange w/6 in Extension |
63 |
LB 2 in 150 Lb. ANSI Flange, Flush Mount |
64 |
LC 1 in 150 Lb. ANSI Flange, Flush Mount |
65 |
LD 3 in 150 Lb. ANSI Flange w/2 in Extension |
66 |
LE 3 in 150 Lb. ANSI Flange w/4 in Extension |
67 |
LF 3 in 150 Lb. ANSI Flange w/6 in Extension |
68 |
LG 2 in 150 Lb. ANSI Flange w/2 in Extension |
69 |
LH 2 in 150 Lb. ANSI Flange w/4 in Extension |
70 |
LI 2 in 150 Lb. ANSI Flange w/6 in Extension |
71 |
LJ 4 in 150 Lb. ANSI Flange w/2 in Extension |
72 |
LK 4 in 150 Lb. ANSI Flange w/4 in Extension |
73 |
LL 4 in 150 Lb. ANSI Flange w/6 in Extension |
74 |
quarter inch eighteen National Pipe Thread (NPT) |
75 |
half inch fourteen National Pipe Thread (NPT) |
76 |
none |
77 |
unknown |
78 |
special |
79 |
Di Octyl Phthalate |
80 |
Di Methyl Phthalate |
81 |
Krytox 1506 |
82 |
Krytox 143 |
83 |
Halocarbon 4.2 |
84 |
Heavy Mineral Oil |
85 |
Safflower Oil |
86 |
Sweet Almond Oil |
87 |
Sensors |
88 |
Construction |
89 |
Damping |
90 |
Review |
91 |
Analog output |
92 |
HART |
93 |
Write protect info |
94 |
Descriptive info |
95 |
Manufacturer info |
96 |
Range sensor |
97 |
Config sensor |
98 |
Trim sensor |
99 |
Sensor limits |
100 |
Restore/reset |
101 |
Remote seal info |
102 |
Pressure sensor |
103 |
Temperature sensor |
104 |
Sensor approval, certification & rating codes |
105 |
approval |
106 |
UL (Underwriters' Laboratory) |
107 |
CENELEC Flameproof |
108 |
CENELEC Intrinsic Safety |
109 |
FM Explosion Proof |
110 |
FM Intrinsically Safe (Loop) |
111 |
FM Intrinsically Safe (Entity) |
112 |
FM Hazardous Locations |
113 |
FM Suitable for Use/Intrinsically Safe |
114 |
FM Non-Incendive |
115 |
CSA Explosion Proof |
116 |
CSA Intrinsically Safe |
117 |
CSA Hazardous Locations |
118 |
CE |
119 |
3A (Sanitary Standards Administrative Council) |
120 |
ABS (American Bureau of Ships) |
121 |
API (American Petroleum Institute) |
122 |
USDA |
123 |
NEMA 1 |
124 |
NEMA 2 |
125 |
NEMA 3 |
126 |
NEMA 3R |
127 |
NEMA 4 |
128 |
NEMA 4X |
129 |
NEMA 5 |
130 |
NEMA 6 |
131 |
NEMA 9 |
132 |
NEMA 12 |
133 |
NEMA 13 |
134 |
approvals |
135 |
Raw analog output DAC counts |
136 |
DAC counts |
137 |
Raw SV AD counts |
138 |
SV AD counts |
139 |
Raw PV AD counts |
140 |
PV AD counts |
141 |
Sensor Fill Fluid- Fluid material in the module. |
142 |
Syltherm 800 |
143 |
Glycerine/Water |
144 |
Propylene Glycol/Water |
145 |
Neobee M20 |
146 |
Pressure |
147 |
.2f |
148 |
4.3f |
149 |
.3f |
150 |
3.2f |
151 |
6.2f |
152 |
Upper Reference Value- Defines an upper reference temperature; Used for correction of the primary variable |
153 |
Temp URV |
154 |
Lower Reference Valu- Defines a lower reference temperature; used for correction of the primary variable |
155 |
Temp LRV |
156 |
Sensor serial # |
157 |
16d |
158 |
Used to change the password |
159 |
Password |
160 |
Defines errors detected by the self test routine |
161 |
Self test errors |
162 |
FLASH chksum fail |
163 |
FLASH checksum failure |
164 |
RAM rd/wr fail |
165 |
RAM read/write test failure |
166 |
EEPROM corrupt |
167 |
EEPROM corruption test failure |
168 |
Sensor failure |
169 |
Electronics failure |
170 |
Not used |
171 |
Defines warnings generated by the self test routine |
172 |
Self test warnings |
173 |
Out of 4-20 rng |
174 |
Analog output out of 4-20 mA range |
175 |
Wrt protect err |
176 |
Write protect fault |
177 |
Unused data bytes |
178 |
Compensation mode flag indicating digital compensation of input errors. Asserted when compensation is active. |
179 |
Compensation mode |
180 |
on |
181 |
off |
182 |
Damping mode flag indicating whether or not the damping is active |
183 |
Damping mode |
184 |
temp upper ref |
185 |
temp lower ref |
186 |
Zero trim - Make the sensor input the new zero input reference. Sensor gain trim point is adjusted. |
187 |
Temp upper trim |
188 |
Temp low trim |
189 |
Self test |
190 |
Master reset |
191 |
Reset config chgd |
192 |
Resets the configuration changed flag |
193 |
Write prtct cntrl |
194 |
Changes the write protect setting of the transmitter |
195 |
Comp mode on/off |
196 |
Turns on/off digital compensation of input errors. |
197 |
Damp mode on/off |
198 |
Turns on/off damping of input |
199 |
This command performs the function of setting the PV Analog Output Current Failure Alarm mode of the device to allow a prespecified current condition upon a hardware failure condition as indicated by an over pressure condition, sensor malfunction or other condition requiring notification to the analog control system |
200 |
Select alarm code |
201 |
Restr fctry set |
202 |
This command will restore all original factory settings to the slave device. It will destroy, by overwriting, any user calibration, notes, messages, tags, or other modifications which have been entered into the slave device by the user |
203 |
Write_variables |
204 |
FMU860 |
205 |
DT |
206 |
DVC |
207 |
FCX |
208 |
AS800 |
209 |
340T |
210 |
340C |
211 |
344 |
212 |
Siemens Micro K |
213 |
SITRANS L |
214 |
SIPAN PH |
215 |
SITRANS P |
216 |
75SMT |
217 |
UNIDELTA |
218 |
8320 |
219 |
SX5100 |
220 |
TSV175 |
221 |
DMU |
222 |
3780 |
223 |
BM70 |
224 |
8u |
225 |
Measurement Type- Type of measurement application this Field Device is intended to be used with. |
226 |
Flange Material- Construction material of flange type. |
227 |
Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. |
228 |
6.4f |
229 |
.4f |
230 |
Remote Seal Isolator Material- Construction material of a part of the remote seal type that comes in contact with the process material. This is only unambiguous if 1 remote seal is installed. |
231 |
Sensor Isolator Material- Construction material of a part of the module type that comes in contact with the process material. |
232 |
Drain Vent Material- Construction material of a removable plug that exists on the flange type that can be opened temporarily to remove unwanted process from the sensor area. |
233 |
Upper Sensor Trim Point- Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. |
234 |
Pressure Sensor Upper Trim- Calibrate the pressure sensor. |
235 |
Apply hi pressure |
236 |
Press OK when pressure is stable |
237 |
Enter applied pressure value |
238 |
trim_point |
239 |
Remove pressure |
240 |
Remote Seal Fill Fluid- Fluid material in the device remote seal. |
241 |
--WARNING!! |
242 |
Soak unit at high reference temp |
243 |
Press OK when temp is stable |
244 |
Enter temp value in %{0} |
245 |
The upper temperature ref is trimmed at %{1} %{0} |
246 |
Soak unit at low reference temp |
247 |
Enter temp value in %{0} |
248 |
The lower temperature reference is trimmed at %{1} %{0} |
249 |
Performing transmitter self test
--Please Wait-- |
250 |
Device maybe stuck in Master Reset |
251 |
Self Test OK |
252 |
About to perform master reset |
253 |
Master Reset in progress - please wait |
254 |
--please wait! |
255 |
Master reset complete |
256 |
Configuration changed flag successfully reset |
257 |
You are entering write protect mode |
258 |
You are exiting write protect mode |
259 |
Please enter the eight character password- blanks are valid |
260 |
Transaction completed successfully |
261 |
Turning compensation off... |
262 |
Turning compensation on... |
263 |
WARNING!!... |
264 |
Compensation is turned off |
265 |
Compensation is turned on |
266 |
Turning damping on... |
267 |
Turning damping off... |
268 |
Damping is turned on |
269 |
Please choose failure alarm setting |
270 |
High;Low;Hold last value |
271 |
The alarm state is set as %{0} |
272 |
Proceed with restoration? |
273 |
Restoring original factory settings - PLEASE WAIT! |
274 |
--please wait |
275 |
Original factory settings restored |
276 |
Enter desired output... |
277 |
Would you like to try again? |
278 |
Yes;No |
279 |
Zero set as %{1}. |
280 |
The unit must be reranged to within 5% of FSPR |
281 |
FSPR set as %{1}. |