0 |
LF4xx/220 |
1 |
ROM error |
2 |
RAM error |
3 |
CPU error |
4 |
EX curr open |
5 |
H over spec |
6 |
Reverse flow |
7 |
H alarm |
8 |
L alarm |
9 |
Empty |
10 |
EX curr error |
11 |
EEPROM error |
12 |
Invalid total |
13 |
Ref error |
14 |
ADC error |
15 |
Chk circuit error |
16 |
Disp or sw error |
17 |
Less |
18 |
JWWA 75 |
19 |
JIS 10K |
20 |
JIS 16K |
21 |
JIS 20K |
22 |
Unknown |
23 |
Special |
24 |
Flow rate. |
25 |
.3f |
26 |
FO- Forward flow direction integral value. |
27 |
FO |
28 |
RV- Reverse flow direction integral value. |
29 |
RV |
30 |
DF- Difference between the forward and reverse integral value. |
31 |
DF |
32 |
Flow rate unit. |
33 |
PV unit |
34 |
mL/s |
35 |
mL/min |
36 |
mL/h |
37 |
Unit |
38 |
mL |
39 |
Damping value |
40 |
2.1f |
41 |
AO |
42 |
8.3f |
43 |
PV% range |
44 |
Low cut value- refers to the function for fixing the current output to 0% when the flow rate drops below the low cut value preset near 0%. |
45 |
Low cut value |
46 |
Excitation current code. |
47 |
Ex.Curr. |
48 |
A |
49 |
.4f |
50 |
R1- Range 1 span value. |
51 |
R1 |
52 |
.5f |
53 |
8.5f |
54 |
R2- Range 2 span value. |
55 |
R2 |
56 |
R3- Range 3 span value. |
57 |
R3 |
58 |
R4- Range 4 span value. |
59 |
R4 |
60 |
Single: Single range. F4: Unidirectional flow, automatic selection of multiple ranges. F=2, R=2: Bi-directional flows, automatic selection of multiple ranges. EXT F=2: Unidirectional flow, multiple ranges selected by external signal. EXT F=2, R=2: Bi-directional flows, multiple ranges selected by external signal. |
61 |
Type |
62 |
Single |
63 |
Single range |
64 |
F4 |
65 |
Unidirectional flow, automatic selection of multiple ranges |
66 |
F=2, R=2 |
67 |
Bidirectional flows, automatic selection of multiple ranges |
68 |
EXT F=2 |
69 |
Unidirectional flow, multiple ranges selected by external signal |
70 |
EXT F=2, R=2 |
71 |
Bidirection flows, multiple ranges selected by external signal |
72 |
Fixed pulse. |
73 |
Fixed pulse |
74 |
Hz |
75 |
6d |
76 |
Hysteresys- Set the blind sector width associated with range switching. |
77 |
Hysteresys |
78 |
3d |
79 |
Count rate unit |
80 |
Count rate- For the integral counter, the amount per count (pulse or count rate) is set. |
81 |
Count rate |
82 |
Pulse width- When the integral pulse is externally output, the pulse width is set. |
83 |
Pulse width |
84 |
ms |
85 |
Preset count- Preset value of preset counter is set. |
86 |
Preset count |
87 |
8d |
88 |
Excitation frequency code. |
89 |
EX.Freq. |
90 |
6 Hz |
91 |
12 Hz |
92 |
24 Hz |
93 |
START: Totalizer mode start. STOP: Totalizer mode stop. RESET: Count reset. |
94 |
START/STOP |
95 |
START |
96 |
STOP |
97 |
RESET |
98 |
Meter size- Detector Inlet Diameter. |
99 |
Meter size |
100 |
5d |
101 |
High alarm- Flow-rate high limit alarm value. |
102 |
High alarm |
103 |
Low alarm- Flow-rate low limit alarm value. |
104 |
Low alarm |
105 |
Alarm set (ON/OFF) |
106 |
Empty alarm |
107 |
Limit rate |
108 |
Limit time |
109 |
7d |
110 |
Detector serial number. |
111 |
Detector serial |
112 |
Converter serial number. |
113 |
Converter serial |
114 |
Detector CAT.code. |
115 |
Detector CAT.code |
116 |
Converter CAT.code. |
117 |
Converter CAT.code |
118 |
Calibration Mode |
119 |
1d |
120 |
Calibration Step |
121 |
Seal matl |
122 |
Chloroprene |
123 |
EDPM |
124 |
Lining material |
125 |
Teflon PFA |
126 |
Ceramic |
127 |
EPDM rubber |
128 |
Electrode material |
129 |
SUS316L |
130 |
Ha-C |
131 |
Ta |
132 |
Ti |
133 |
Pt-Ir |
134 |
Earthring material |
135 |
SUS316 |
136 |
SUS304 |
137 |
Not provided |
138 |
Flange type |
139 |
Wafer |
140 |
JWWA75 |
141 |
JIS10K |
142 |
JIS16K |
143 |
JIS20K |
144 |
JIS30K |
145 |
JIS63K |
146 |
ANSI150 |
147 |
ANSI300 |
148 |
BS10 |
149 |
BS16 |
150 |
DIN PN 10 |
151 |
DIN PN 16 |
152 |
Clamp type |
153 |
Screw type |
154 |
Rc(PT)1/4 |
155 |
Rc(PT)1/8 |
156 |
Rc(PT)3/8 |
157 |
Rc(PT)1/2 |
158 |
NPT1/4 |
159 |
NPT3/8 |
160 |
DO1- Digital output 1: Semiconductor contact output. |
161 |
DO1 |
162 |
No use |
163 |
None input |
164 |
Upper limit alarm output |
165 |
lower limit alarm output |
166 |
Empty alarm output |
167 |
Range sig 1 |
168 |
Range status signal (1) output |
169 |
Range sig 2 |
170 |
Range status signal (2) output |
171 |
Preset out |
172 |
Preset count status output |
173 |
Conv alarm |
174 |
Self-diagnostic alarm output |
175 |
Pulse out |
176 |
Scaled pulse output |
177 |
DO2- Digital output 2: Semiconductor contact output. |
178 |
DO2 |
179 |
DI- Digital input: Voltage signal input. |
180 |
DI |
181 |
Counter sta/stp |
182 |
Start/Stop control input of internal counter |
183 |
Counter rst/sta |
184 |
Stop/Start control input of internal counter |
185 |
Range switch |
186 |
External range change control input |
187 |
Zero adjustment |
188 |
Zero adjustment signal input |
189 |
Fixed out |
190 |
Fixed out mode control input |
191 |
Alarm action. |
192 |
Alarm action |
193 |
DO1/2 Normal close |
194 |
DO1/DO2 Normal close |
195 |
DO1 NO / DO2 NC |
196 |
DO1 Normal open / DO2 Normal close |
197 |
DO1 NC / DO2 NO |
198 |
DO1 Normal close / DO2 Normal open |
199 |
DO1/2 Normal open |
200 |
DO1/DO2 Normal open |
201 |
EX current |
202 |
Self test |
203 |
EMF zero- Make zero-point adjustment, with the fluid within the measuring pipe of the detector completely at a halt. |
204 |
EMF zero |
205 |
Calibration |
206 |
PV% display- PV% is displayed every 1 second. Calibration start- 0% calibration start. Exit- Exit and back to menu. |
207 |
FLOW CAL 0% |
208 |
PV% display- PV% is displayed every 1 second. Calibration start- 100% calibration start. Exit- Exit and back to menu. |
209 |
FLOW CAL 100% |
210 |
EX.CURR.DSP. |
211 |
Limit of change- The change rate limitation provides the function for suppressing sudden variations in converter flow rate signal output generated when too much noise is contained in the flow rate signal. |
212 |
Limit of change |
213 |
High alarm value- Flow-rate high limit alarm value. |
214 |
Review2 |
215 |
Range type binding mismatch |
216 |
Range unit error |
217 |
Pulse rate unit error |
218 |
Range value too large |
219 |
Range value too small |
220 |
Multi range setting error |
221 |
Pulse rate too large |
222 |
Pulse rate too small |
223 |
Pulse width too large |
224 |
Pulse width too small |
225 |
Not in proper mode |
226 |
Total flow |
227 |
Information |
228 |
User information |
229 |
Detector |
230 |
Serial number |
231 |
CAT.code |
232 |
DI/DO |
233 |
Totalizer |
234 |
Review1 |
235 |
FMU860 |
236 |
DT |
237 |
DVC |
238 |
FCX |
239 |
AS800 |
240 |
340T |
241 |
340C |
242 |
344 |
243 |
Siemens Micro K |
244 |
SITRANS L |
245 |
SIPAN PH |
246 |
SITRANS P |
247 |
75SMT |
248 |
UNIDELTA |
249 |
8320 |
250 |
SX5100 |
251 |
TSV175 |
252 |
DMU |
253 |
3780 |
254 |
BM70 |
255 |
8u |
256 |
6.4f |
257 |
5.3f |
258 |
Device maybe stuck. |
259 |
Self test OK! |
260 |
Select mode |
261 |
PV display;Adjust start;Exit |
262 |
%{0} %{1} |
263 |
Now Adjusting
Please wait... |
264 |
Adjust OK! |
265 |
ZR %{0} %
If you adjust Zr,
press OK |
266 |
Span %{0} %
If you adjust Span,
press OK |
267 |
EX %{0} mA
If you adjust Ex,
press OK |
268 |
Calibration OK! |
269 |
PV% display;Calibration start;Exit |
270 |
PV% range %{0} % |
271 |
Now Calibrating
Please wait... |
272 |
Please wait... |
273 |
Excitation current
%{0} A
press OK |
274 |
Select flange type group. [Wafer] |
275 |
Flange type;Sanitary type;Small meter size;Unknown;Special |
276 |
Select flange type group. [JWWA75] |
277 |
Select flange type group. [JIS10K] |
278 |
Select flange type group. [JIS16K] |
279 |
Select flange type group. [JIS20K] |
280 |
Select flange type group. [JIS30K] |
281 |
Select flange type group. [JIS63K] |
282 |
Select flange type group. [ANSI150] |
283 |
Select flange type group. [ANSI300] |
284 |
Select flange type group. [BS10] |
285 |
Select flange type group. [BS16] |
286 |
Select flange type group. [DIN PN 10] |
287 |
Select flange type group. [DIN PN 16] |
288 |
Select flange type group. [Clamp type] |
289 |
Select flange type group. [Screw type] |
290 |
Select flange type group. [Rc(PT)1/4] |
291 |
Select flange type group. [Rc(PT)1/8] |
292 |
Select flange type group. [Rc(PT)3/8] |
293 |
Select flange type group. [Rc(PT)1/2] |
294 |
Select flange type group. [NPT1/4] |
295 |
Select flange type group. [NPT3/8] |
296 |
Select flange type group. [Unknown] |
297 |
Select flange type group. [Special] |
298 |
Select flange type group. |
299 |
Select flange type. |
300 |
Wafer;JWWA75;JIS10K;JIS16K;JIS20K;JIS30K;JIS63K;ANSI150;ANSI300;BS10;BS16;DIN PN 10;DIN PN 16 |
301 |
Select sanitary type. |
302 |
Clamp type;Screw type |
303 |
Select small meter size. |
304 |
Rc(PT)1/4;Rc(PT)1/8;Rc(PT)3/8;Rc(PT)1/2;NPT1/4;NPT3/8 |
305 |
Hysteresys %{hys11} % |
306 |
hys21 |
307 |
Value was too low |
308 |
Count rate %{count_rate1} |
309 |
count_rate1 |
310 |
Fixed pulse %[3.0f]{fp11} pps |
311 |
fp21 |
312 |
Meter size %[3.1f]{d_size11} mm |
313 |
d_size21 |
314 |
Limit rate %[3.1f]{percent_rate_limit11} % |
315 |
percent_rate_limit21 |
316 |
Limit time %[3.1f]{time_rate_limit11} s |
317 |
time_rate_limit21 |
318 |
Pulse width %[3.1f]{pulse_width11} ms |
319 |
pulse_width21 |
320 |
Pulse width too low |
321 |
Preset count %{preset_counter} |
322 |
preset_counter |
323 |
High alarm %[3.1f]{alarm_upper_value11} % |
324 |
alarm_upper_value21 |
325 |
Value was too high |
326 |
low alarm %[3.1f]{alarm_lower_value11} % |
327 |
alarm_lower_value21 |
328 |
Hysteresys %[3.1f]{dat2} % |
329 |
Meter size %[3.1f]{dat2} mm |
330 |
Limit rate %[3.1f]{dat2} % |
331 |
Limit time %[3.1f]{dat2} s |
332 |
Preset count %{dat3} |
333 |
High alarm %[3.1f]{dat2} % |
334 |
Low alarm %[3.1f]{dat2} % |