0 |
Pipe desc -User message to describe the pipe. |
1 |
Density of Carrier -The density of the carrier liquid. |
2 |
Density of carrier |
3 |
Density of Matl -The density of the solid material in the slurry. |
4 |
Density of material |
5 |
Adapt Damp Status -Control to activate adaptive damping. |
6 |
Adapt Damp Status |
7 |
Adapt Damp Value -The damping time used when the adaptive damping is active. |
8 |
Adapt Damp Value |
9 |
Damping Threshold -Percent deviation from last value where the adaptive damping becomes active. |
10 |
Damping Threshold |
11 |
% |
12 |
Process desc -User entered description of process. |
13 |
Temp Comp Status -This option turns the temperature compensation on and off. |
14 |
Temp Comp Status |
15 |
Ref Temp |
16 |
Expansion Coef |
17 |
Rho1 -The density of the process at the first temperature. |
18 |
Rho2 -The density of the process at the second temmperature. |
19 |
Temp1 -The temperature at which the first density value is recorded. |
20 |
Temp1 |
21 |
Temp2 -The temperature at which the second density value is recorded. |
22 |
Temp2 |
23 |
Zero Value |
24 |
Span value |
25 |
Last ref -The date on which the last reference was taken on the device. |
26 |
Last ref |
27 |
Ref hr |
28 |
Ref min |
29 |
6.0f |
30 |
Counts |
31 |
Cal Point Number |
32 |
#1DENSITY--The density value for the first calibration point. This point is always used for the calibration curve. |
33 |
#1DENSITY |
34 |
#1SIGNAL--The signal value for the first calibration point. This point is always used for the calibration curve. |
35 |
#1SIGNAL |
36 |
#2DENSITY--The density value for the second calibration point. This point is always used for the calibration curve. |
37 |
#2DENSITY |
38 |
g/CuCm |
39 |
#2SIGNAL--The signal value for the second calibration point. This point is always used for the calibration curve. |
40 |
#2SIGNAL |
41 |
#3DENSITY--The density value for the third calibration point. If this calibration point is not used, the density should be set to zero. |
42 |
#3DENSITY |
43 |
#3SIGNAL--The signal value for the third calibration point. This point is not used if the density for point three is zero. |
44 |
6.4f |
45 |
#3SIGNAL |
46 |
#4DENSITY--The density value for the fourth calibration point. If this calibration point is not used, the density should be set to zero. |
47 |
#4DENSITY |
48 |
#4SIGNAL--The signal value for the fourth calibration point. This point is not used if the density for point four is zero. |
49 |
#4SIGNAL |
50 |
#5DENSITY--The density value for the fifth calibration point. If this calibration point is not used, the density should be set to zero. |
51 |
#5DENSITY |
52 |
#5SIGNAL--The signal value for the fifth calibration point. This point is not used if the density for point five is zero. |
53 |
#5SIGNAL |
54 |
#6DENSITY--The density value for the sixth calibration point. If this calibration point is not used, the density should be set to zero. |
55 |
#6DENSITY |
56 |
#6SIGNAL--The signal value for the sixth calibration point. This point is not used if the density for point six is zero. |
57 |
#6SIGNAL |
58 |
Cal Point 1 |
59 |
Cal Point 2 |
60 |
Cal Point 3 |
61 |
Cal Point 4 |
62 |
Cal Point 5 |
63 |
Cal Point 6 |
64 |
Samp Duration--The time of the sample measurement. The maximum value is 600 seconds. |
65 |
Samp Duration |
66 |
Density Offset--A value supplied by the user and added to the density value measured. |
67 |
Dens Offset |
68 |
Temp Comp Input Sensor Type -The type of sensor used to measure temperature. |
69 |
Temp Sensor Type |
70 |
4 to 20mA |
71 |
Temp Comp Units -The units associated with the device used for temperature compensation. |
72 |
Units |
73 |
Zero Point Value -The zero range point for the temperature transmitter. |
74 |
Zero Point Value |
75 |
Span Value -The high range point for the temperature transmitter. |
76 |
Span Value |
77 |
Last setup locatn |
78 |
Ref Material -The material selected for the next reference. |
79 |
Source Type -The type of source contained in the source housing. |
80 |
Date |
81 |
2d |
82 |
Time-Hrs |
83 |
Time-Mins |
84 |
5.0f |
85 |
PV Units- Engineering unit that the process variable, UPPER_RANGE_VALUE, LOWER_RANGE_VALUE, LOWER_SENSOR_LIMIT, and UPPER_SENSOR_LIMIT will be displayed with. |
86 |
PV Units |
87 |
Process variable -The density or unit value that is proportional to the output current. It changes as the density of the process material changes. |
88 |
4.4f |
89 |
Analog Output -The current at the transmitter output whose value changes as the density of the process material. |
90 |
PV Output |
91 |
2.2f |
92 |
PV % of range -A value that is the per cent of full scale. |
93 |
USL Upper Sensor Limit -The highest value that the upper range value can be set to. |
94 |
USL |
95 |
LSL Lower Sensor Limit -The lowest value that the lower range value can be set to. |
96 |
LSL |
97 |
URV Upper Range Value -The density value that corresponds to 20mA output current. |
98 |
URV |
99 |
LRV Lower Range Value -The density value that corresponds to 4mA output current. |
100 |
LRV |
101 |
PV Damp -The time constant of the transmitter. It is used to smooth the output. |
102 |
4.1f |
103 |
Temp Units |
104 |
Temp -The temperature of the process material. This is the temperature used during temperature compensation. |
105 |
Temp |
106 |
Snsr s/n -A means of identifying each transmitter with a unique number. |
107 |
Device Setup |
108 |
Diag/Service |
109 |
Calibrate |
110 |
Reference |
111 |
Process Sample |
112 |
Basic Setup |
113 |
Range and Units |
114 |
Date and time |
115 |
Damping |
116 |
Detailed Setup |
117 |
Temp Comp |
118 |
Comp Parameters |
119 |
Sensor Type |
120 |
Output Trim |
121 |
REVIEW |
122 |
Write Variables |
123 |
Test Device -Directs the 3680 electronics to perform a selftest. Reports any errors that occured. |
124 |
Test Device |
125 |
Calibration Curve |
126 |
New Reference |
127 |
New Sample |
128 |
RTD |
129 |
4 to 20 mA |
130 |
None |
131 |
Wait for a time |
132 |
FMU860 |
133 |
DT |
134 |
DVC |
135 |
FCX |
136 |
AS800 |
137 |
340T |
138 |
340C |
139 |
344 |
140 |
Siemens Micro K |
141 |
SITRANS L |
142 |
SIPAN PH |
143 |
SITRANS P |
144 |
75SMT |
145 |
UNIDELTA |
146 |
8320 |
147 |
SX5100 |
148 |
TSV175 |
149 |
DMU |
150 |
3780 |
151 |
BM70 |
152 |
8u |
153 |
low |
154 |
high |
155 |
tmp_av |
156 |
WARN -Loop should be removed from automatic control |
157 |
Testing Xmtr PLEASE WAIT |
158 |
Self Test complete Tests PASS |
159 |
NOTE-Loop may be returned to automatic control |
160 |
Point 1;Point 2;Point 3;Point 4;Point 5;Point 6 |
161 |
#%{num}DENSITY %{den} #%{num}SIGNAL %{sig} |
162 |
Change Density;Change Signal;Select New Point;End Changes |
163 |
#%{num}DENSITY |
164 |
den |
165 |
#%{num}SIGNAL |
166 |
sig |
167 |
WARNING--Accepting new calibration curve will reset offset |
168 |
Accept Curve;Reject Curve |
169 |
New calibration curve rejected |
170 |
Making changes permanent. Please Wait... |
171 |
ERROR -- Sample being taken |
172 |
WARNING -- Reference measurement in progress Please Wait... |
173 |
Device may be stuck in reference mode. |
174 |
Reference Complete Ref Count %0 |
175 |
Accept;Reject |
176 |
WARNING--This will reset offset |
177 |
Procced;Abort |
178 |
Reference Rejected |
179 |
Making Changes permanent |
180 |
Time Corrupt... |
181 |
NOTICE--Reference will take %0 sec |
182 |
Start;Exit |
183 |
Taking reference measurement. Please Wait... |
184 |
Device may be stuck in reference mode. |
185 |
Procced;Reject reference |
186 |
ERROR -- Reference in progress. |
187 |
NOTICE --Sample will take %0 sec |
188 |
Taking -- Sample measurement. Please Wait. |
189 |
Device may be stuck in sample mode. |
190 |
RTD sensor type selected. |
191 |
Last calibration was %0 |
192 |
Select type of RTD calibration |
193 |
Factory;User |
194 |
Restoring factory RTD calibration. Please Wait... |
195 |
Connect LOW setpoint resistance to RTD input |
196 |
Proceed;End |
197 |
Enter LOW setpoint resistance value |
198 |
Do you wish to correct the problem and try again? |
199 |
Yes;No |
200 |
LOW setpoint being changed to user calibration. PLEASE WAIT.... |
201 |
Low setpoint value accepted. |
202 |
Connect HIGH setpoint resistance to RTD input |
203 |
Enter HIGH setpoint resistance value |
204 |
HIGH Setpoint being changed to user calibration. PLEASE WAIT.... |
205 |
High setpoint value accepted. |
206 |
4 to 20 mA sensor type selected. |
207 |
4 to 20 mA sensor |
208 |
Set temp for 4mA;Set temp for 20mA;Trim current input;End |
209 |
Enter temperature for 4mA |
210 |
Enter temperature for 20mA |
211 |
Last trim was %0 |
212 |
Select type of temp sensor trim |
213 |
Restoring factory trim values. Please Wait... |
214 |
Set temp input to 4mA |
215 |
Enter input current value |
216 |
4mA value being changed to user trimed value. PLEASE WAIT... |
217 |
4mA trim value accepted. |
218 |
Set temp input to 20mA |
219 |
20mA value being changed to user trimed value. PLEASE WAIT... |
220 |
20mA trim value accepted. |
221 |
No sensor type selected. |