0x00FE0001 |
invalid_selection |
Invalid selection |
0x00FE0002 |
passed_parameter_too_large |
Value was too high |
0x00FE0003 |
passed_parameter_too_small |
Value was too low |
0x00FE0004 |
too_few_data_bytes_recieved |
Too few data bytes received |
0x00FE004E |
invalid_poll_address_selection |
Invalid poll address selection |
0x00FE004F |
invalid_date_code_detected |
Invalid date code detected |
0x00FF0006 |
no_command_specific_errors |
No specific error |
0x00FF0007 |
xmtr_specific_command_error |
Field device specific error |
0x00FF0008 |
access_restricted |
Access restricted |
0x00FF0009 |
update_failure |
Update fail |
0x00FF000E |
Command_not_implemented |
Command not implemented |
0x01000001 |
in_write_protect_mode |
In write protect mode |
0x01000009 |
busy |
Busy |
0x0100000A |
delayed_response_initiated |
Delayed response initiated |
0x0100000B |
delayed_response_running |
Delayed response running |
0x0100000C |
delayed_response_dead |
Delayed response dead |
0x0100000D |
delayed_response_conflict |
Delayed response conflict |
0x0100000F |
invalid_mode_selection |
Invalid mode selection |
0x01080001 |
buffer_overflow |
Buffer overflow |
0x01080002 |
longitudinal_parity_error |
Longitudinal parity error |
0x01080003 |
framing_error |
Framing error |
0x01080004 |
overrun_error |
Overrun error |
0x01080005 |
vertical_parity_error |
Vertical parity error |
0x0115000F |
success |
Success |
0x01190007 |
number_of_request_preambles |
Num req preams |
0x01190008 |
universal_revision |
Universal rev |
0x01190009 |
transmitter_revision |
Fld dev rev |
0x0119000A |
software_revision |
Software rev |
0x0119000B |
hardware_revision |
Hardware rev |
0x0119000D |
device_identification |
Dev id |
0x0119000E |
polling_address |
Poll addr |
0x0119000F |
tag |
Tag |
0x01190010 |
message |
Message |
0x01190011 |
descriptor |
Descriptor |
0x01190012 |
date |
Date |
0x01190015 |
final_assembly_number |
Final asmbly num |
0x01190030 |
number_of_response_preambles |
Num resp preams |
0x01190195 |
maximum_number_of_device_variables |
Max dev vars |
0x01190196 |
configuration_change_counter |
Cfg chng count |
0x01190198 |
command_specific_response_code |
Response code |
0x01190199 |
communications_error_summary |
Communication status |
0x0119019B |
long_tag |
Long tag |
0x0124001B |
final_assembly_number_help |
Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device |
0x0124001E |
date_help |
Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. |
0x0124001F |
discriptor_help |
Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. |
0x01240020 |
message_help |
Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. |
0x01240021 |
polling_address_help |
Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) |
0x01240022 |
field_device_identification_help |
Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. |
0x01240025 |
hardware_revision_help |
Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device |
0x01240026 |
field_device_software_revision_help |
Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device |
0x01240027 |
field_device_revision_help |
Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to |
0x01240028 |
universal_revision_help |
Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to |
0x01240029 |
number_of_request_preambles_help |
Number of Request Preambles- Number of Preambles required from the Host request by the Field Device |
0x0124002D |
communications_error_summary_help |
Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. |
0x0124002E |
command_specific_response_code_help |
Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. |
0x01240043 |
number_of_response_preambles_help |
Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host |
0x01240062 |
tag_help |
Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. |
0x0124007D |
maximum_number_of_device_variables_help |
Maxium Number of Device Variables- This indicates the last Device Variable code that a host application should expect to be found in the field device (e.g., when identifying the Device Variables using Command 54) |
0x0124007E |
configuration_change_counter_help |
Configuration Change Counter- This indicates the number of times the devices configuration or calibration has been changed by a host application or from a local operator interface |
0x01240080 |
long_tag_help |
Long Tag- Functions exactly like Tag except the size is larger (max of 32 ISO Latin 1 characters) |
0x01900003 |
default_label |
No Label Available |
0x01910001 |
hart_block_label |
|