0 |
ND820/T |
1 |
Neles-Jamesbury |
2 |
Exit fixed position |
3 |
Force to 0% |
4 |
Force to 100% |
5 |
To fail-safe pos |
6 |
To anti fail-safe |
7 |
Device is busy |
8 |
Measured value not acceptable |
9 |
Calculated database value not in proper range |
10 |
Bias adjust failed |
11 |
Calibrating |
12 |
Running test |
13 |
Trimming prestage |
14 |
State of ND800 |
15 |
The state of field device: normal operation, testing etc. |
16 |
Calibration error |
17 |
Test error |
18 |
Prstg trim err |
19 |
Device status |
20 |
Calibration, test or trim may fail, this variable tells if the failure has occurred |
21 |
RAM error |
22 |
ROM error |
23 |
EEPROM error |
24 |
Watchdog reset |
25 |
Digital HW error |
26 |
Status of digital hardware |
27 |
Current saturation |
28 |
Position saturation |
29 |
Pressure saturation |
30 |
Analog sensor err |
31 |
Status of analog hardware sensors |
32 |
Curr circuit fail |
33 |
Pos meas fail |
34 |
Press meas fail |
35 |
Pilot vlv1 fail |
36 |
Pilot vlv2 fail |
37 |
Analog HW errors |
38 |
Status of analog hardware |
39 |
3.0f |
40 |
% |
41 |
Split range low |
42 |
The split range low limit |
43 |
Split range high |
44 |
The split range high limit |
45 |
Data not acceptable, low limit >= high limit |
46 |
4.1f |
47 |
Supply pressure |
48 |
User given supply pressure |
49 |
Undefined |
50 |
Single acting |
51 |
Double acting |
52 |
Actuator type |
53 |
The type of actuator can be single or double acting |
54 |
Stop |
55 |
Start |
56 |
Prstg trim ctrl |
57 |
Prestage trim control, starts or stops |
58 |
Failure info |
59 |
Stop prestage trim |
60 |
Emergency stop of prestage trim |
61 |
Trim prestage unit |
62 |
Automatic trim of prestage unit |
63 |
W |
64 |
|
65 |
PCB S/N |
66 |
The serial number of component board module |
67 |
State can be normal operation, calibratig or running test |
68 |
Normal operation |
69 |
Calibration status |
70 |
Calibration may fail, this variable tells if the failure has occurred |
71 |
No error |
72 |
Position gain |
73 |
Position control gain value. The higher gain results to faster response. |
74 |
5.2f |
75 |
Dead angle comp |
76 |
Control valve dead angle as percent of calibrated valve travel range |
77 |
Pos sensor rot |
78 |
Sets the relationship between the rotation direction of position sensor shaft and valve travel |
79 |
Clockwise opens |
80 |
Clockwise closes |
81 |
Signal direction |
82 |
Sets the relationship between the direction of input signal and valve travel |
83 |
Valve closed at 4 mA |
84 |
Valve open at 4 mA |
85 |
Modification control |
86 |
Set the modification curve use |
87 |
Curve OFF |
88 |
Curve ON |
89 |
Safety range |
90 |
Sets the value of input signal in percent of range at which valve is fully closed |
91 |
Parameter B |
92 |
The actuator type specific feedback parameter B of position control |
93 |
Parameter D |
94 |
The actuator type specific feedback parameter D of position control |
95 |
Activate calibration |
96 |
Set the value to activate position feedback calibration. |
97 |
Normal mode |
98 |
Calibration mode |
99 |
Pos sensor S/N |
100 |
The serial number of position sensor module |
101 |
ND800 S/N |
102 |
The serial number of the ND800 valve controller written into the identification plate |
103 |
Temp compensation |
104 |
Position temperature compensation state |
105 |
Off |
106 |
On |
107 |
Max acttr prs mde |
108 |
Drives actuator into fail-safe position |
109 |
Pressure snsr rnge |
110 |
The linear measurement range of the pressure sensor module |
111 |
Measured prs diff |
112 |
Measured pressure difference |
113 |
5.4f |
114 |
Valve fixed pos |
115 |
Drives valve to a predefined position |
116 |
Pos sensor angle |
117 |
Position sensor angle |
118 |
deg |
119 |
Pos sensor range |
120 |
Position sensor linear range in the degrees of angle |
121 |
ADC bias |
122 |
Target ADC value for biasing |
123 |
Measured temp |
124 |
The measured ambient temperature |
125 |
Temp sensor snstvty |
126 |
Temperature sensor sensitivity value of ND800, see IMO. |
127 |
7.6f |
128 |
Compensation temperature |
129 |
-?- |
130 |
-40 degC |
131 |
-35 degC |
132 |
-30 degC |
133 |
-25 degC |
134 |
-20 degC |
135 |
-15 degC |
136 |
-10 degC |
137 |
- 5 degC |
138 |
0 degC |
139 |
+ 5 degC |
140 |
+10 degC |
141 |
+15 degC |
142 |
+20 degC |
143 |
+25 degC |
144 |
+30 degC |
145 |
+35 degC |
146 |
+40 degC |
147 |
+45 degC |
148 |
+50 degC |
149 |
+55 degC |
150 |
+60 degC |
151 |
+65 degC |
152 |
+70 degC |
153 |
+75 degC |
154 |
+80 degC |
155 |
+85 degC |
156 |
Table code |
157 |
Pos sensor min output |
158 |
Position sensor minimum linear output as percent of supply voltage at corresponding temperature |
159 |
Pos sensor max output |
160 |
Position sensor maximum linear output as percent of supply voltage at corresponding temperature |
161 |
Flow modification point |
162 |
0 % |
163 |
10 % |
164 |
20 % |
165 |
30 % |
166 |
40 % |
167 |
50 % |
168 |
60 % |
169 |
70 % |
170 |
80 % |
171 |
90 % |
172 |
100 % |
173 |
Flow modification value |
174 |
4.2f |
175 |
Event item number |
176 |
Latest event |
177 |
2nd event |
178 |
3rd event |
179 |
4th event |
180 |
5th event |
181 |
6th event |
182 |
7th event |
183 |
8th event |
184 |
9th event |
185 |
10th event |
186 |
11th event |
187 |
12th event |
188 |
13th event |
189 |
14th event |
190 |
15th event |
191 |
16th event |
192 |
17th event |
193 |
18th event |
194 |
19th event |
195 |
20th event |
196 |
Event time |
197 |
6.2f |
198 |
Event code |
199 |
OK |
200 |
Power Error |
201 |
Setpoint Error |
202 |
Calibration OK |
203 |
Position diff. Error |
204 |
Calibration Error |
205 |
Diagnostics Error |
206 |
Position Sensor Error |
207 |
Pressure Sensor Error |
208 |
EEPROM Error |
209 |
Memory Error |
210 |
CPU Error |
211 |
Reset |
212 |
Operation hours |
213 |
Total operation time in hours |
214 |
Valve travel cntr |
215 |
Number of full strokes of valve |
216 |
Valve cycle cntr |
217 |
Number of reversals of valve |
218 |
Act travel cntr |
219 |
Number of full stokes of actuator |
220 |
Act cycle cntr |
221 |
Number of reversals of actuator |
222 |
Input sig |
223 |
The measured current value in the 4-20 mA input signal loop. |
224 |
mA |
225 |
Input signal units |
226 |
Valve trv |
227 |
The measured valve travel as percent of the calibrated valve travel range |
228 |
Valve trv units |
229 |
The units of valve travel |
230 |
Vlv trv SP |
231 |
The valve travel setpoint as percent of the calibrated valve travel range |
232 |
Valve travel SP units |
233 |
The units of valve travel setpoint |
234 |
Act pres |
235 |
The actuator pressure difference in 1- and 2-acting actuators (proportional to actuator load) |
236 |
Pressure units |
237 |
Sets the displayed pressure units |
238 |
Temp |
239 |
The temperature of the device |
240 |
Temperature units |
241 |
Sets the displayed temperature units |
242 |
Foovar |
243 |
8u |
244 |
Warn |
245 |
-WARNING- The positioner will not function properly if the calib sequence failed. |
246 |
Event log |
247 |
View event log |
248 |
Select event log index |
249 |
Event time %{0} hours
%{1} |
250 |
View other events? |
251 |
Yes;No |
252 |
Pressure sensor |
253 |
Pressure sensor module calibration |
254 |
Release actuator pressure and check that actuator pressure is equal to air pressure |
255 |
About to set pressure measurement zero |
256 |
Connect actuator supply pressure |
257 |
About to enter maximum actuator pressure mode. WARNING! This causes movement of actuator |
258 |
Select pressure units |
259 |
Enter pressure sensor range (%{0}) |
260 |
Enter meter value (%{0}) |
261 |
About to set pressure measurement span |
262 |
Please check that the value you entered is reasonable and re-enter the correct value. |
263 |
About to exit maximum actuator pressure mode. WARNING! This causes movement of actuator |
264 |
Pressure sensor module calibration done |
265 |
Position sensor |
266 |
Position sensor module calibration, temperature compensation and identification |
267 |
Enter position sensor serial number |
268 |
Enter position sensor linear range |
269 |
Adjust position sensor to 50% of the sensor linear range (see instructions in IMO) |
270 |
About to set position measurement bias. Check position sensor adjustment |
271 |
Please wait ... |
272 |
About to set temperature compensation data for position sensor |
273 |
Select range of compensation temperature |
274 |
-40 degC to 0 degC;+5 degC to +45 degC;+50 degC to +85 degC |
275 |
Select compensation temperature |
276 |
-40 degC;-35 degC;-30 degC;-25 degC;-20 degC;-15 degC;-10 degC;- 5 degC;0 degC |
277 |
+ 5 degC;+10 degC;+15 degC;+20 degC;+25 degC;+30 degC;+35 degC;+40 degC;+45 degC |
278 |
+50 degC;+55 degC;+60 degC;+65 degC;+70 degC;+75 degC;+80 degC;+85 degC |
279 |
Pos sensor min output at %{0} |
280 |
Pos sensor max output at %{0} |
281 |
Set other temperature values? |
282 |
Position sensor module calibration done |
283 |
Custom linearization |
284 |
Sets customized travel curve of the control valve to linearize the relationship between valve travel setpoint and flow |
285 |
Select valve travel SP |
286 |
0%;10%;20%;30%;40%;50%;60%;70%;80%;90%;100% |
287 |
Set flow linearized valve travel at %{0} travel SP |
288 |
Set other points? |
289 |
Flow linearized valve travel curve set. |
290 |
Temp measurement |
291 |
Temperature ADC zero calibration of the component board module |
292 |
Temperature units |
293 |
About to set temperature measurement ADC zero |
294 |
Temperature measurement calibration done. |
295 |
Input signal |
296 |
Input signal ADC zero and span (4-20mA) calibration of the component board module |
297 |
Adjust loop current to 4 mA |
298 |
About to set input signal ADC zero (4mA) |
299 |
Adjust loop current to 20 mA |
300 |
About to set input signal ADC span (20mA) |
301 |
Input signal ADC calibration done |
302 |
Stop calibration |
303 |
Emergency stop of calibration |
304 |
Calibration stopped. |
305 |
Auto calib travel |
306 |
Automatic calibration of control valve travel against mechanical travel limits corresponding to 0-100% input signal |
307 |
Calibration or test is running. Cannot start calibration. |
308 |
WARNING! Ensure that control valve movement do not disturb process! |
309 |
About to start calibration |
310 |
Calibrating ... |
311 |
Calibration failed. Check positioner. |
312 |
Calibration timeout, possible error in positioner. |
313 |
Calibration done |
314 |
Unit code advise |
315 |
Remember to send a changed unit code to the device! |
316 |
Set ND800 S/N |
317 |
Stores the serial number of the ND800 valve controller into the nonvolatile memory of the ND800. Must be set when component board is replaced |
318 |
Enter ND serial number in format YYYYWWNNNN |
319 |
mfc_nb |
320 |
Incorrect format. |
321 |
Device S/N succesfully set. |
322 |
Reset valve cntrs |
323 |
Resets the valve counters to zero |
324 |
Are you sure? |
325 |
Valve counters reset done. |
326 |
Reset act cntrs |
327 |
Resets the actuator counters to zero |
328 |
Actuator counters reset done. |
329 |
Position transmitter |
330 |
Position transmitter DAC zero and span calibration |
331 |
About to set position transmitter output to 4 mA |
332 |
Output will be set - ok? |
333 |
Is position transmitter output equal to 4 mA? |
334 |
About to set position transmitter output to 20 mA |
335 |
Is position transmitter output equal to 20 mA? |
336 |
Position transmitter calibration done. |
337 |
Hot key |
338 |
Valve Controller |
339 |
Main menu |
340 |
Basic config |
341 |
Cntl valve asmbly |
342 |
Pos cntl tune |
343 |
Detailed config |
344 |
Travel control |
345 |
Flow characteriz |
346 |
Module calib |
347 |
Monitor settings |
348 |
Diagnostics |
349 |
Valve statistics |
350 |
Serial numbers |
351 |
Trim stopped. |
352 |
Calibration, test or trim is running. Cannot trim. |
353 |
Plug the cylinder pressure outputs C1 and C2 |
354 |
About to trim |
355 |
Trimming... |
356 |
Trim failed. Check positioner. |
357 |
Trim timeout, possible error in positioner. |
358 |
Trim done |
359 |
Unplug the cylinder pressure outputs C1 and C2 |
360 |
|