Loading…
Loading…
Reference ID | Label | String |
---|---|---|
0x00190001 | density_3680 | 3680 Dens |
0x00190002 | steam_quality_3280 | 3280 Steam qual |
0x001A0001 | ABB_DPK_pressure | DPK Pres |
0x001A0002 | ABB_PX_pressure | PX Pres |
0x001A0003 | ABB_DPK_temperature | DPK Temp |
0x001A0004 | valve_positioner | Valve Position |
0x001A0005 | flow_device | Flow |
0x001A0006 | level_device | Level |
0x001F0001 | mass_flow_9712 | 9712 Mass flo |
0x001F0002 | mass_flow_9739 | 9739 Mass flo |
0x001F0003 | mass_flow_9701 | 9701 |
0x001F0004 | mass_flow_9720 | 9720 |
0x00260001 | pressure_3051 | 3051 |
0x00260002 | pressure_1151s | 1151 |
0x00260003 | pressure_3001c | 3001C HTG |
0x00260004 | pressure_3001l | 3001L HTG |
0x00260005 | pressure_3051c | 3051C |
0x00260006 | temperature_3044 | 3044 Temp |
0x00260007 | mag_flow_8712 | Magmeter |
0x00260008 | mag_flow_8712H | Mag HS |
0x00260009 | htg_3201 | 3201 SAM |
0x0026000A | htg_3202 | 3202 SAM |
0x0026000B | temperature_3044C | 3044C Temp |
0x0026000C | pressure_1152s | 1152 |
0x0026000D | vortex_flow_8800 | Vortex |
0x0026000E | pressure_3051clp | 3051C LP |
0x0026000F | pressure_3001s | 3001S HTG |
0x00260010 | pressure_2001 | 2001 |
0x00260011 | level_4050 | 4050 |
0x00260012 | ascii_term | ASCII Term |
0x00260014 | mv_3095 | 3095MV |
0x00260015 | temperature_544 | 544 Temp |
0x00260016 | temperature_644 | 644 Temp |
0x00260017 | temperature_3144 | 3144 Temp |
0x00260018 | temperature_3244 | 3244 Temp |
0x00260019 | multi_3095FT | 3095FT |
0x0026001A | level_3700 | 3700 |
0x0026001B | level_3750 | 3750 |
0x0026001C | TRI_LOOP | Tri-Loop |
0x0026001D | c_3095 | 3095C |
0x0026001E | mm_3095 | 3095MM |
0x0026001F | tank_3701 | 3701 |
0x00260020 | level_3300 | 3300 |
0x00260021 | asu_3702 | 3702ASU |
0x00260022 | pressure_2088s | 2088 Smart |
0x00260023 | probar | ProBar |
0x00260024 | massprobar | Mass ProBar |
0x00260025 | prov | ProV |
0x00260026 | pressure_2090s | 2090 Smart |
0x00260027 | probar_uc | ProBar UC |
0x00260028 | d_2055 | 2055D |
0x00260029 | pv_3095 | 3095PV |
0x0026002A | sentry | Sentry |
0x002E0001 | ph_1181 | 2081 pH |
0x002E0002 | ph_1054 | 2054 pH |
0x002E0003 | conductivity_1181 | 2081 Cond |
0x002E0004 | conductivity_1054 | 2054 Cond |
0x002E0005 | ph_3081 | 3081pH |
0x002E0006 | c_3081 | 3081C |
0x002E0007 | ph_orp_54 | 54pH/ORP |
0x002E0008 | c_54 | 54eC |
0x00FA0001 | InH2O | inH2O |
0x00FA0002 | InHg | inHg |
0x00FA0003 | FtH2O | ftH2O |
0x00FA0004 | mmH2O | mmH2O |
0x00FA0005 | mmHg | mmHg |
0x00FA0006 | psi | psi |
0x00FA0007 | bar | bar |
0x00FA0008 | mbar | mbar |
0x00FA0009 | g_SqCm | g/Sqcm |
0x00FA000A | kg_SqCm | kg/Sqcm |
0x00FA000B | PA | Pa |
0x00FA000C | kPA | kPa |
0x00FA000D | torr | torr |
0x00FA000E | ATM | atm |
0x00FA000F | CuFt_min | Cuft/min |
0x00FA0010 | gal_min | gal/min |
0x00FA0011 | l_min | L/min |
0x00FA0012 | ImpGal_min | Impgal/min |
0x00FA0013 | CuMtr_hr | Cum/h |
0x00FA0014 | ft_s | ft/s |
0x00FA0015 | mtr_s | m/s |
0x00FA0016 | gal_s | gal/s |
0x00FA0018 | l_s | L/s |
0x00FA0019 | MilL_day | ML/d |
0x00FA001A | CuFt_s | Cuft/s |
0x00FA001B | CuFt_day | Cuft/d |
0x00FA001C | CuMtr_s | Cum/s |
0x00FA001D | CuMtr_day | Cum/d |
0x00FA001E | ImpGal_hr | Impgal/h |
0x00FA001F | ImpGal_day | Impgal/d |
0x00FA0020 | degC | degC |
0x00FA0021 | degF | degF |
0x00FA0022 | degR | degR |
0x00FA0023 | Kelvin | Kelvin |
0x00FA0024 | mV | mV |
0x00FA0025 | Ohm | ohm |
0x00FA0026 | Hz | Hz |
0x00FA0027 | mA | mA |
0x00FA0028 | gal | gal |
0x00FA0029 | liter | L |
0x00FA002A | ImpGal | Impgal |
0x00FA002B | CuMtr | Cum |
0x00FA002C | ft | ft |
0x00FA002D | meter | m |
0x00FA002E | bbl | bbl |
0x00FA002F | in | in |
0x00FA0030 | cm | cm |
0x00FA0031 | mm | mm |
0x00FA0032 | min | min |
0x00FA0033 | sec | s |
0x00FA0034 | hr | h |
0x00FA0035 | day | d |
0x00FA0036 | cpoise | cP |
0x00FA0037 | uMho | uMho |
0x00FA0038 | Percent | % |
0x00FA0039 | v | V |
0x00FA003A | pH | pH |
0x00FA003B | gram | g |
0x00FA003C | kg | kg |
0x00FA003D | MetTon | MetTon |
0x00FA003E | lb | lb |
0x00FA003F | ShTon | STon |
0x00FA0040 | LTon | LTon |
0x00FA0041 | g_s | g/s |
0x00FA0042 | g_min | g/min |
0x00FA0043 | g_hr | g/h |
0x00FA0044 | kg_s | kg/s |
0x00FA0045 | kg_min | kg/min |
0x00FA0046 | kg_hr | kg/h |
0x00FA0047 | kg_day | kg/d |
0x00FA0048 | MetTon_min | MetTon/min |
0x00FA0049 | MetTon_hr | MetTon/h |
0x00FA004A | MetTon_day | MetTon/d |
0x00FA004B | lb_s | lb/s |
0x00FA004C | lb_min | lb/min |
0x00FA004D | lb_hr | lb/h |
0x00FA004E | lb_day | lb/d |
0x00FA004F | ShTon_min | STon/min |
0x00FA0050 | ShTon_hr | STon/h |
0x00FA0051 | ShTon_day | STon/d |
0x00FA0052 | LTon_hr | LTon/h |
0x00FA0053 | LTon_day | LTon/d |
0x00FA0054 | SGU | SGU |
0x00FA0055 | g_CuCm | g/Cucm |
0x00FA0056 | kg_CuMtr | kg/Cum |
0x00FA0057 | lb_gal | lb/gal |
0x00FA0058 | lb_CuFt | lb/Cuft |
0x00FA0059 | g_ml | g/mL |
0x00FA005A | kg_l | kg/L |
0x00FA005B | g_l | g/L |
0x00FA005C | lb_CuIn | lb/Cuin |
0x00FA005D | ShTon_CuYd | STon/Cuyd |
0x00FA005E | degTwad | degTwad |
0x00FA005F | degBrix | degBrix |
0x00FA0060 | degBaum_hv | degBaum hv |
0x00FA0061 | degBaum_lt | degBaum lt |
0x00FA0062 | degAPI | degAPI |
0x00FA0063 | Percent_sol_wt | % sol-wt |
0x00FA0064 | Percent_sol_vol | % sol-vol |
0x00FA0065 | degBall | degBall |
0x00FA0066 | proof_vol | proof/vol |
0x00FA0067 | proof_mass | proof/mass |
0x00FA0068 | bush | bush |
0x00FA0069 | CuYd | Cuyd |
0x00FA006A | CuFt | Cuft |
0x00FA006B | CuIn | Cuin |
0x00FA006C | mtr_hr | m/h |
0x00FA006D | CuFt_hr | Cuft/h |
0x00FA006E | CuMtr_min | Cum/min |
0x00FA006F | bbl_s | bbl/s |
0x00FA0070 | bbl_min | bbl/min |
0x00FA0071 | bbl_hr | bbl/h |
0x00FA0072 | bbl_day | bbl/d |
0x00FA0073 | gal_hr | gal/h |
0x00FA0074 | ImpGal_s | Impgal/s |
0x00FA0075 | l_hr | L/h |
0x00FA0076 | percent_StmQual | % Stm Qual |
0x00FA0077 | Ftin16 | ft.in16 |
0x00FA0078 | CuFt_lb | Cuft/lb |
0x00FA0079 | Percent_plato | % plato |
0x00FA007A | centi_stokes | cSt |
0x00FA007B | pico_farads | pF |
0x00FA007C | mega_pascals | MPa |
0x00FA007D | in_H2O_4_degrees_C | inH2O @4DegC |
0x00FA007E | mm_H2O_4_degrees_C | mmH2O @4DegC |
0x00FA007F | hecto_liter | hL |
0x00FA0080 | gallons_per_day | gal/d |
0x00FA0081 | bbl_liq | bbl(liq) |
0x00FA0082 | ounce | ounce |
0x00FA0083 | foot_pound_force | ft lbf |
0x00FA0084 | kilo_watt | kW |
0x00FA0085 | kilo_watt_hour | kWh |
0x00FA0086 | horsepower | hp |
0x00FA0087 | mega_calorie | Mcal |
0x00FA0088 | mega_joule | MJ |
0x00FA0089 | british_thermal_unit | Btu |
0x00FA008A | normal_cubic_meter | NmlCum |
0x00FA008B | normal_liter | NmlL |
0x00FA008C | standard_cubic_feet | StdCuft |
0x00FA008D | mega_calorie_per_hour | Mcal/h |
0x00FA008E | mega_joule_per_hour | MJ/h |
0x00FA008F | british_thermal_unit_per_hour | Btu/h |
0x00FA0090 | normal_cubic_meter_per_hour | NmlCum/h |
0x00FA0091 | normal_liter_per_hour | NmlL/h |
0x00FA0092 | standard_cubic_feet_per_minute | StdCuft/min |
0x00FA0093 | deka_therm | datherm |
0x00FA0094 | parts_per_million | ppm |
0x00FA0095 | MillionGal_day | MMgal/d |
0x00FA0096 | uSiemen_cm | uS/cm |
0x00FA0097 | mSiemen_cm | mS/cm |
0x00FA0098 | kOhm | kO |
0x00FA0099 | newton | N |
0x00FA009A | newton_meter | Nm |
0x00FA009B | in_s | in/s |
0x00FA009C | in_min | in/min |
0x00FA009D | ft_min | ft/min |
0x00FA009E | deg_s | deg/s |
0x00FA009F | rpm | rpm |
0x00FA00A0 | degrees | deg |
0x00FA00A1 | rev_s | rev/s |
0x00FA00A2 | radian | rad |
0x00FA00A3 | in_H2O_60_degrees_F | inH2O @60DegF |
0x00FA00A4 | ug_l | ug/L |
0x00FA00A5 | ug_m3 | ug/Cum |
0x00FA00A6 | percent_consistency | %Cs |
0x00FA00A7 | volume_percent | Vol% |
0x00FA00A8 | ml_l | mL/L |
0x00FA00A9 | ul_l | uL/L |
0x00FA00AA | percent_lel | %LEL |
0x00FA00AB | ppb | ppb |
0x00FB0001 | linear | Linear |
0x00FB0002 | square_root | Sq root |
0x00FB0007 | special_curve | Spcl curve |
0x00FB0008 | square_root_plus_special_curve | Sq root+ spcl curve |
0x00FB0009 | square_root_to_the_third_power_plus_special_curve | Sq R to 3rd P+SCurv |
0x00FB000A | square_root_to_the_fifth_power_plus_special_curve | Sq R to 5th P+SC |
0x00FB000B | square_root_to_the_third_power_sup | Sq root to 3rd powr |
0x00FB000C | square_root_to_the_fifth_power_sup | Sq root to 5th powr |
0x00FB000D | square | Square |
0x00FB000E | discrete_switch | discrete (switch) |
0x00FC0001 | carbon_steel | Carbon Steel |
0x00FC0002 | stainless_steel_304 | 304 SST |
0x00FC0003 | stainless_steel_316 | 316 SST |
0x00FC0004 | hastelloy_c | Hast-C |
0x00FC0005 | monel | Monel |
0x00FC0006 | tantalum | Tantalum |
0x00FC0007 | titanium | Titanium |
0x00FC0008 | pt_ir | Pt-Ir |
0x00FC0009 | alloy_20 | Alloy 20 |
0x00FC000A | co_cr_ni | Co-Cr-Ni |
0x00FC000B | ptfe | PTFE |
0x00FC000C | vito | Viton |
0x00FC000D | buna_n | Buna-N |
0x00FC000E | ethyl_prop | Ethyl-Prop |
0x00FC000F | urethane | Urethane |
0x00FC0011 | tefzel | Tefzel |
0x00FC0012 | ryton | Ryton |
0x00FC0013 | ceramic | Ceramic |
0x00FC0015 | pvc | PVC |
0x00FC0016 | nitrile_rubber | Nitrile Rubber |
0x00FC0017 | kalrez | Kalrez |
0x00FC0018 | inconel | Inconel |
0x00FC0019 | kynar | Kynar |
0x00FC001A | aluminium | Al |
0x00FC001B | nickel | Nickel |
0x00FC001C | hastelloy_c276 | Hast-C276 |
0x00FC001D | monel_400 | Monel-400 |
0x00FC001E | fep | FEP |
0x00FC001F | stainless_steel_316_ti | 316 SST Ti |
0x00FC0020 | gold_monel | Gold monel |
0x00FC0021 | stainless_steel_316l_sup | 316L SST |
0x00FC0022 | klinger_c4401 | 4401 |
0x00FC0023 | thermotork | Thermotork |
0x00FC0024 | grafoil | Grafoil |
0x00FC0025 | ptfe_coated_316l_sst | PTFE coated 316L SST |
0x00FC0026 | gold_plated_hastelloy_c276 | Gold plated Hast C276 |
0x00FC0027 | ptfe_graphite | PTFE Graphite |
0x00FC0028 | ptfe_glass | PTFE Glass |
0x00FC0029 | PTFE_hastelloy | PTFE/Hastelloy |
0x00FC002A | stainless_steel_CF_8M | SST CF-8M |
0x00FC002B | hastelloy_sst | Hastelloy C/SST |
0x00FC002C | gold_plated_sst | gold plated SST |
0x00FC002D | aflas | Aflas |
0x00FD0001 | Acromag | Acromag |
0x00FD0002 | Allen_Bradley | Allen Bradley |
0x00FD0003 | Ametek | Ametek |
0x00FD0004 | Analog_Devices | Analog Devices |
0x00FD0006 | Beckman | Beckman |
0x00FD0007 | Bell_Microsensor | Bell Microsensor |
0x00FD0008 | Bourns | Bourns |
0x00FD0009 | Bristol_Babcock | Bristol Babcock |
0x00FD000A | Brooks_Instrument | Brooks Instrument |
0x00FD000B | Chessell | Chessell |
0x00FD000C | Combustion_Engineering | Combustion Engineering |
0x00FD000D | Daniel_Industries | Daniel Industries |
0x00FD000E | Delta | Delta |
0x00FD000F | Dieterich_Standard | Dieterich Standard |
0x00FD0010 | Dohrmann | Dohrmann |
0x00FD0011 | Endress_and_Hauser | Endress & Hauser |
0x00FD0013 | Fisher_Controls | Fisher Controls |
0x00FD0014 | Foxboro | Foxboro |
0x00FD0015 | Fuji | Fuji |
0x00FD0017 | Honeywell | Honeywell |
0x00FD0018 | ITT_Barton | ITT Barton |
0x00FD0019 | KayRay_Sensall | Kay Ray/Sensall |
0x00FD001A | Kent | Kent |
0x00FD001B | Leeds_and_Northrup | Leeds & Northrup |
0x00FD001C | Leslie | Leslie |
0x00FD001D | M_System_Co | M-System Co. |
0x00FD001E | Measurex | Measurex |
0x00FD001F | Micro_Motion | Micro Motion |
0x00FD0020 | Moore_Industries | Moore Industries |
0x00FD0021 | Moore_Products | Moore Products |
0x00FD0022 | Ohkura_Electric | Ohkura Electric |
0x00FD0023 | Paine | Paine |
0x00FD0024 | Rochester_Instrument_Systems | Rochester Instrument Systems |
0x00FD0025 | Ronan | Ronan |
0x00FD0026 | Rosemount | Rosemount |
0x00FD0028 | Schlumberger | Schlumberger |
0x00FD0029 | Sensall | Sensall |
0x00FD002A | Siemens | Siemens |
0x00FD002C | Toshiba | Toshiba |
0x00FD002D | Transmation | Transmation |
0x00FD002E | Rosemount_Analytical | Rosemount Analytic |
0x00FD002F | Valmet | Valmet |
0x00FD0031 | Varec | Varec |
0x00FD0032 | Viatran | Viatran |
0x00FD0033 | Weed | Weed |
0x00FD0034 | Westinghouse | Westinghouse |
0x00FD0035 | Xomox | Xomox |
0x00FD0036 | Yamatake | Yamatake |
0x00FD0037 | Yokogawa | Yokogawa |
0x00FD0038 | Nuovo_Pignone | Nuovo Pignone |
0x00FD0039 | Promac | Promac |
0x00FD003A | Exac_Corporation | Exac Corporation |
0x00FD003B | KDG_Mobrey | KDG Mobrey |
0x00FD003C | Acrom_Control_System | Arcom Control Systems |
0x00FD003D | Oval | Oval |
0x00FD003E | Princo | Princo |
0x00FD003F | Smar | Smar |
0x00FD0041 | Measurement_Technology | Measurement Technology |
0x00FD0042 | Applied_System_Technologies | Applied System Technologies |
0x00FD0043 | Samson | Samson |
0x00FD0044 | Sparling_Instruments | Sparling Instruments |
0x00FD0045 | Fireye | Fireye |
0x00FD0046 | Krohne | Krohne |
0x00FD0047 | Betz_Equipment | Betz |
0x00FD0048 | Druck | Druck |
0x00FD0049 | SOR | SOR |
0x00FD004A | Elcon_Instruments | Elcon Instruments |
0x00FD004B | EMCO | EMCO |
0x00FD004C | Termiflex | Termiflex Corporation |
0x00FD004D | VAF_Instruments | VAF Instruments |
0x00FD004E | Westlock_Controls | Westlock Controls |
0x00FD004F | Drexelbrook | Drexelbrook |
0x00FD0050 | K_TEK | K-TEK |
0x00FD0051 | Flowdata | Flowdata |
0x00FD0052 | Draeger | Draeger |
0x00FD0053 | Raytek | Raytek |
0x00FD0054 | Meridian_Instruments | Meridian Instruments |
0x00FD0055 | BTG | BTG |
0x00FD0056 | Magnetrol | Magnetrol |
0x00FD0058 | Milltronics | Milltronics |
0x00FD0059 | HELIOS | HELIOS |
0x00FD005A | Anderson_Instrument_Company | Anderson Instrument Company |
0x00FD005B | INOR | INOR |
0x00FD005C | ROBERTSHAW | ROBERTSHAW |
0x00FD005D | PEPPERL_FUCHS | PEPPERL+FUCHS |
0x00FD005E | ACCUTECH | ACCUTECH |
0x00FD005F | Flow_Measurement | Flow Measurement, Inc. |
0x00FD0060 | KAMSTRUP | KAMSTRUP |
0x00FD0061 | Knick | Knick |
0x00FD0062 | VEGA | VEGA |
0x00FD0063 | MTS_SYS_CORPS_SENSORS | MTS Systems Corp. |
0x00FD0064 | Masoneilan_DRESSER | Masoneilan-Dresser |
0x00FD0065 | Besta | BESTA |
0x00FD0066 | Peek_Measurement | Peek Measurement |
0x00FD0067 | Ohmart | Ohmart |
0x00FD0068 | Harold_Beck_and_Sons | Harold Beck and Sons, Inc. |
0x00FD0069 | rittmeyer_instrumentation | rittmeyer instrumentation |
0x00FD006A | rossel_messtechnik | Rossel Messtechnik |
0x00FD006B | WIKA | WIKA |
0x00FD006C | Bopp_and_Reuther_Heinrichs | Bopp&Reuther Heinrichs |
0x00FD006D | pr_eletronics | PR Electronics |
0x00FD006E | jordan_controls | Jordan Controls |
0x00FD006F | valcom | Valcom s.r.l. |
0x00FD0070 | us_electric_motors | US ELECTRIC MOTORS |
0x00FD0071 | apparatebau_hundsbach | Apparatebau Hundsbach |
0x00FD0072 | saab_tank_control | Saab Tank Control |
0x00FD0073 | Elsag_Bailey | Elsag Bailey |
0x00FD0074 | Foxboro_Eckardt | FOXBORO ECKARDT |
0x00FD0075 | Neles_Controls | Neles Controls |
0x00FD0076 | ISE_Magtech | ISE-Magtech |
0x00FD0077 | Delta_Weed | Delta/Weed |
0x00FD0078 | Dynisco | Dynisco |
0x00FD0079 | Spriano | Spriano |
0x00FD007A | Direct_Mesaurement | Direct Measurement |
0x00FD007B | Klay | Klay Instruments |
0x00FD007C | Action | Action Instruments |
0x00FD007D | Mmg_Automatiky | MMG Automatiky DTR |
0x00FD007E | Buerkert | Buerkert Fluid Control Systems |
0x00FD007F | Hersey | Hersey Measurement |
0x00FD0080 | Pondus | PONDUS INSTRUMENTS |
0x00FD0081 | Zap | ZAP S.A. Ostrow Wielkopolski |
0x00FD0082 | GLI | GLI |
0x00FD0083 | FRPT | Fisher-Rosemount Performance Technologies |
0x00FD0084 | Paper_Machine_Components | Paper Machine Components |
0x00FD0085 | Labom | LABOM |
0x00FD0086 | Danfoss | Danfoss |
0x00FD0087 | Turbo | Turbo |
0x00FD0088 | Tokyo_Keiso | TOKYO KEISO |
0x00FD0089 | SMC | SMC |
0x00FD008A | Status_Instruments | Status Instruments |
0x00FD008B | Huakong | Huakong |
0x00FD008C | Duon_System | Duon System |
0x00FD008D | Vortek_Instruments_LLC | Vortek Instruments, LLC |
0x00FD008E | AG_Crosby | AG Crosby |
0x00FD008F | Action_Instruments | Action Instruments |
0x00FD0090 | Keystone_Controls | Keystone Controls |
0x00FD0091 | Thermo_Electric_Company | Thermo Electric Co. |
0x00FD0092 | Flowserve | Flowserve |
0x00FE0001 | invalid_selection | Invalid selection |
0x00FE0002 | passed_parameter_too_large | Value was too high |
0x00FE0003 | passed_parameter_too_small | Value was too low |
0x00FE0004 | too_few_data_bytes_recieved | Too few data bytes received |
0x00FE0005 | lower_range_value_too_high | Lower range value too high |
0x00FE0007 | invalid_flange_type | Invalid flange type |
0x00FE0008 | lower_range_value_too_low | Lower range value too low |
0x00FE000A | upper_range_value_too_high | Upper range value too high |
0x00FE000C | upper_range_value_too_low | Upper range value too low |
0x00FE0012 | URV_and_LRV_out_of_limits | Lower range value and upper range value out of limits |
0x00FE0016 | set_to_nearest_possible_value | Set to nearest possible value |
0x00FE0018 | span_too_small | Span too small |
0x00FE0019 | new_LRV_pushed_URV_over_USL | New lower range value pushed upper range value over upper sensor limit |
0x00FE001B | invalid_transmitter_variable | Invalid field device variable code |
0x00FE001C | invalid_units | Invalid unit |
0x00FE001D | invalid_analog_output_number_code | Invalid analog output number code |
0x00FE0020 | invalid_alarm_config_code | Invalid alarm relay configuration code |
0x00FE0023 | invalid_alarm_number_code | Invalid alarm number code |
0x00FE0026 | invalid_liner_material_code | Invalid liner material code |
0x00FE0027 | invalid_sensor_material_code | Invalid sensor material code |
0x00FE0028 | invalid_base_mass_time_units | Invalid base mass time unit |
0x00FE0029 | invalid_base_mass_flow_units | Invalid base flow unit |
0x00FE002E | invalid_base_volume_time_units | Invalid base volume time unit |
0x00FE002F | invalid_base_volume_flow_units | Invalid base volume flow unit |
0x00FE0030 | incorrect_format | Incorrect format |
0x00FE0039 | invalid_alarm_xmtr_var_code | Invalid alarm variable index into field device variables |
0x00FE004C | invalid_transfer_function_code | Invalid transfer function |
0x00FF0004 | update_in_progress | Update In progress |
0x00FF0006 | no_command_specific_errors | No specific error |
0x00FF0007 | xmtr_specific_command_error | Field device specific error |
0x00FF0008 | access_restricted | Access restricted |
0x00FF0009 | update_failure | Update fail |
0x01000001 | in_write_protect_mode | In write protect mode |
0x01000002 | not_in_proper_current_mode | Not in fixed current mode |
0x01000003 | not_in_proper_anlg_output_mode | Not in analog output mode |
0x01000007 | in_multidrop_mode | In multidrop mode |
0x01010001 | applied_process_too_high | Applied process too high |
0x01010002 | applied_process_too_low | Applied process too low |
0x01020007 | electronics_failure | Electronics failure |
0x01020021 | sensor_failure | Sensor failure |
0x01040002 | xcscalcorr_zero_to_low | Excess calibration correction, zero too low |
0x01040003 | xcscalcorr_zero_to_hi | Excess calibration correction, zero too high |
0x01060004 | process_too_noisy | Process too noisy to preform automatic zero |
0x01060005 | slug_flow | Slug flow |
0x0107000E | power_reset_occured | Power reset occurred |
0x0107000F | xmtr_warming_up | Field device warming up |
0x01070012 | cal_in_progress | Calibration in progress |
0x01070013 | cal_failed | Calibration failed |
0x01070015 | analog_output_1_saturated | Analog output 1 saturated |
0x01070016 | analog_output_2_saturated | Analog output 2 saturated |
0x01070017 | analog_output_1_fixed | Analog output 1 fixed |
0x01070018 | analog_output_2_fixed | Analog output 2 fixed |
0x01070019 | density_outside_limits | Density outside limits |
0x0107001A | drive_overrange | Drive over range |
0x0107001D | input_overrange | Input over range |
0x0107001E | freq_overrange | Frequency over range |
0x0107001F | xmtr_not_characterized | Field device not characterized |
0x01070020 | rti_failure | Real time interrupt failure |
0x01080001 | buffer_overflow | Buffer overflow |
0x01080002 | longitudinal_parity_error | Longitudinal parity error |
0x01080003 | framing_error | Framing error |
0x01080004 | overrun_error | Overrun error |
0x01080005 | vertical_parity_error | Vertical parity error |
0x01090001 | PV_out_of_limits | Process applied to the primary variable is outside the operating limits of the field device |
0x01090002 | Non_PV_out_of_limits | Process applied to the non-primary variable is outside the operating limits of the field device |
0x01090003 | PV_analog_output_saturated | Analog output 1 and its digital representation are outside the operating range limits, and not responding to input |
0x01090004 | PV_analog_output_fixed | Analog output 1 and its digital representation are in fixed mode, and not responsive to input changes |
0x01090005 | more_status_available | Field device has more status available |
0x01090006 | cold_start | A reset or self test of the field device has occurred, or power has been removed and reapplied |
0x01090007 | configuration_changed | A modification has been made to the configuration of the field device |
0x01090008 | device_malfunction | Field device has malfunctioned due to a hardware error or failure |
0x010D000B | ansi_150 | ANSI 150 |
0x010D000C | ansi_300 | ANSI 300 |
0x010D000D | ansi_600 | ANSI 600 |
0x010D0010 | pn_40 | PN40 |
0x010D0015 | pn_100 | PN100 |
0x010D0016 | ansi_900 | ANSI 900 |
0x010D0017 | jis_10k | JIS 10K |
0x010D0018 | jis_20k | JIS 20K |
0x010D0019 | Union | Union |
0x010D001A | sanitary_clamp_fitting | Sanitary clamp fitting |
0x01120005 | normal | Normal |
0x01150001 | off | Off |
0x01150002 | on | On |
0x0115000A | not_used | Not used |
0x0115000B | none | None |
0x0115000C | unknown | Unknown |
0x0115000D | special | Spcl |
0x0115000E | expansion | Expansion |
0x0115000F | success | Success |
0x01150010 | high | Hi |
0x01150011 | low | Lo |
0x01150016 | do_not_poll | Do not poll |
0x01150017 | poll_as_primary_master | Poll as primary host |
0x01150018 | poll_as_secondary_master | Poll as secondary host |
0x01150019 | forward | Forward |
0x0115001A | reverse | Reverse |
0x0115001B | bi_directional | Bi directional |
0x0115001C | start | Start |
0x0115001D | stop | Stop |
0x0115001E | reset | Reset |
0x01150022 | internal_zero | Intrnl zero |
0x01150043 | bell_202_current | Bell 202 current |
0x01150044 | bell_202_voltage | Bell 202 voltage |
0x01150045 | Multisens_Dev | Multisnsr dev |
0x01150046 | EEPROM_Ctrl | Command #39, EEPROM cntrl, required |
0x01150047 | primary_variable | PV |
0x01150048 | percent_range_and_current | % range/current |
0x01150049 | all_process_variables_and_current | Process vars/crnt |
0x0115004A | burn_eeprom | Burn EEPROM |
0x0115004B | restore_shadow_ram | Restore shadow RAM |
0x0115004C | no | No |
0x0115004D | yes | Yes |
0x0115004E | rs_485 | RS-485 |
0x0115004F | protocol_bridge_device | Protocol bridge dev |
0x01150050 | rs_232 | RS-232 |
0x01160001 | bus_devices | Online |
0x01160004 | detailed_setup | Detailed setup |
0x01160007 | construction_materials | Construction matls |
0x01160014 | process_variables | Process variables |
0x01160029 | hot_key | Hot key |
0x0116002B | diagnostics_and_service | Diag/Service |
0x0116002D | calibration | Calibration |
0x0116002F | basic_setup | Basic setup |
0x01160030 | device_information | Device information |
0x01160031 | revision_numbers | Revision #'s |
0x01160037 | HART_output | HART output |
0x0116003A | review | Review |
0x01170001 | selftest | Self test |
0x0117000B | loop_test | Loop test |
0x0117000C | DAC_trim | D/A trim |
0x0117000D | zero_trim | Zero trim |
0x0117000E | scaled_DAC_trim | Scaled D/A trim |
0x0117000F | leaving_fixed_current_mode | Leaving fixed crnt mode |
0x01170014 | trim_analog_output | Trim analog output |
0x01170015 | fix_analog_output | Fix analog output |
0x0117001D | field_device_variable_zero_trim | Dev var zero trim |
0x0117001E | apply_values | Apply values |
0x01170020 | aborting_return_to_normal | Aborting return to normal |
0x01170021 | set_loop_to_manual | Set loop to manual |
0x01180001 | range_values | Range values |
0x01190005 | manufacturer_id | Manufacturer |
0x01190006 | device_type | Model |
0x01190007 | number_of_request_preambles | Num req preams |
0x01190008 | universal_revision | Universal rev |
0x01190009 | transmitter_revision | Fld dev rev |
0x0119000A | software_revision | Software rev |
0x0119000B | hardware_revision | Hardware rev |
0x0119000C | device_flags | Dev flags |
0x0119000D | device_identification | Dev id |
0x0119000E | polling_address | Poll addr |
0x0119000F | tag | Tag |
0x01190010 | message | Message |
0x01190011 | descriptor | Descriptor |
0x01190012 | date | Date |
0x01190013 | write_protect | Write protect |
0x01190014 | private_label_distributor | Distributor |
0x01190015 | final_assembly_number | Final asmbly num |
0x01190017 | EEPROM_select | EEPROM select |
0x01190018 | xmtr_specific_status_0 | Status group 1 |
0x01190019 | xmtr_specific_status_1 | Status group 2 |
0x0119001A | xmtr_specific_status_2 | Status group 3 |
0x0119001B | xmtr_specific_status_3 | Status group 4 |
0x0119001C | xmtr_specific_status_4 | Status group 5 |
0x0119001D | xmtr_specific_status_5 | Status group 6 |
0x0119001E | operating_mode_1 | Operate mode 1 |
0x0119001F | operating_mode_2 | Operate mode 2 |
0x01190020 | analog_output_saturated | AO saturated |
0x01190021 | analog_output_fixed | AO fixed |
0x0119002A | xmtr_specific_status_14 | Status group 15 |
0x0119002B | xmtr_specific_status_15 | Status group 16 |
0x0119002C | xmtr_specific_status_16 | Status group 17 |
0x0119002D | unit_tag | Dev tag |
0x0119002E | unit_descriptor | Dev des |
0x0119002F | unit_date | Dev date |
0x01190030 | number_of_response_preambles | Num resp preams |
0x01190031 | burst_command_number | Burst option |
0x01190032 | burst_mode_select | Burst mode |
0x01190035 | alarm_select | AO Alrm typ |
0x01190037 | transfer_function | Xfer fnctn |
0x01190054 | liner_material | Liner matl |
0x01190066 | totalizer_control | Totlizer cntrl |
0x01190070 | percent_of_range | % rnge |
0x01190073 | damping_value | Damp |
0x01190078 | sv | SV |
0x0119007A | tv | TV |
0x0119007C | range_units | Rnge unit |
0x0119007D | sensor_serial_number | Snsr s/n |
0x01190086 | sensor_model | Snsr model |
0x01190087 | sensor_material | Snsr matl |
0x01190091 | units | Unit |
0x0119009D | mass_flow_units | Mass flo unit |
0x0119009F | mass_flow_cutoff | Mass flo cutoff |
0x011900A0 | mass_flow_analog_value | Mass flo anlog valu |
0x011900A1 | mass_flow_minimum_span | Mass flo min span |
0x011900A3 | mass_flow_percent_range | Mass flo % rnge |
0x011900A5 | mass_flow_url | Mass flo URL |
0x011900A6 | mass_flow_lrl | Mass flo LRL |
0x011900A7 | mass_flow_urv | Mass flo URV |
0x011900A8 | mass_flow_lrv | Mass flo LRV |
0x011900A9 | mass_total_digital_value | Mass totl |
0x011900AA | mass_total_units | Mass totl unit |
0x011900AD | flow_damping_value | Flo damp |
0x011900AE | temperature_units | Temp unit |
0x011900B0 | temperature_analog_value | Temp anlog valu |
0x011900B1 | temperature_minimum_span | Temp min span |
0x011900B2 | temperature_percent_range | Temp % rnge |
0x011900B4 | temperature_urv | Temp URV |
0x011900B5 | temperature_lrv | Temp LRV |
0x011900B6 | temperature_url | Temp URL |
0x011900B7 | temperature_lrl | Temp LRL |
0x011900B8 | temperature_damping_value | Temp damp |
0x011900BC | density_units | Dens unit |
0x011900BE | density_analog_value | Dens anlog valu |
0x011900BF | density_percent_range | Dens % rnge |
0x011900C1 | density_urv | Dens URV |
0x011900C2 | density_lrv | Dens LRV |
0x011900C3 | density_url | Dens URL |
0x011900C4 | density_lrl | Dens LRL |
0x011900C5 | density_damping_value | Dens damp |
0x011900C6 | density_minimum_span | Dens min span |
0x011900C7 | mass_inventory_digital_value | Mass inventory |
0x011900CA | volume_flow_units | Vol flo unit |
0x011900CB | volume_flow_cutoff | Vol flo cutoff |
0x011900CC | volume_flow_analog_value | Vol flo anlog valu |
0x011900CD | volume_flow_percent_range | Vol flo % rnge |
0x011900CF | volume_flow_urv | Vol flo URV |
0x011900D0 | volume_flow_lrv | Vol flo LRV |
0x011900D1 | volume_flow_url | Vol flo URL |
0x011900D2 | volume_fLow_lrl | Vol flo LRL |
0x011900D3 | volume_flow_minimum_span | Vol flo min span |
0x011900D4 | volume_total_digital_value | Vol totl |
0x011900D5 | volume_total_units | Vol flo totl unit |
0x011900DE | analog_upper_limit | Anlog upr limit |
0x011900DF | analog_lower_limit | Anlog lor limit |
0x011900E0 | analog_units | Anlog unit |
0x011900E1 | add_analog_damping | Added damp |
0x011900E2 | analog_output_1_cutoff | AO1 Cutoff |
0x011900F6 | flow_direction | Flo direction |
0x011900F7 | frequency_factor | Freq factr |
0x011900F8 | rate_factor | Rate factr |
0x01190103 | fixed_frequency | Fixed freq |
0x0119010A | zero | Zero |
0x01190114 | cutoff_type | Cutoff typ |
0x01190170 | physical_signalling_code | Physicl signl code |
0x01190171 | fourth_variable_is | 4V is |
0x01190172 | tertiary_variable_is | TV is |
0x01190173 | secondary_variable_is | SV is |
0x01190174 | primary_variable_is | PV is |
0x01190175 | xmtr_specific_status_17 | Status group 18 |
0x01190176 | xmtr_specific_status_18 | Status group 19 |
0x01190177 | xmtr_specific_status_19 | Status group 20 |
0x01190178 | xmtr_specific_status_20 | Status group 21 |
0x01190179 | xmtr_specific_status_21 | Status group 22 |
0x0119017A | xmtr_specific_status_22 | Status group 23 |
0x0119017B | xmtr_specific_status_23 | Status group 24 |
0x0119017C | xmtr_specific_status_24 | Status group 25 |
0x011A000A | mass_flow | Mass flo |
0x011A000B | temperature | Temp |
0x011A000C | mass_total | Mass totl |
0x011A000D | density | Dens |
0x011A000E | mass_inventory | Mass inventory |
0x011A000F | volume_flow | Vol flo |
0x011A0010 | volume_inventory | Vol inventory |
0x011A0015 | volume_total | Vol totl |
0x011A0016 | analog_1_cutoff | AO1 Cutoff |
0x011A0019 | urv | URV |
0x011A001A | lrv | LRV |
0x011A001B | usl | USL |
0x011A001C | lsl | LSL |
0x011A001D | minimum_span | Min span |
0x011A0020 | analog_output_value | AO |
0x011A0021 | analog_output_units | AO unit |
0x011A0022 | analog_output_lower_endpoint | AO lo end pt |
0x011A0023 | analog_output_upper_endpoint | AO hi end pt |
0x011A0024 | analog_output_add_damping | AO added damp |
0x011D000A | pressure_value_unit | Pressure unit |
0x01240005 | seconds_added_damping_value_help | Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. |
0x01240006 | analog_output_upper_end_point_help | Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions |
0x01240007 | analog_output_lower_end_point_help | Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions |
0x01240008 | digital_units_help | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit |
0x0124000A | percent_of_range_help | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. |
0x0124000C | upper_sensor_limit_help | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value |
0x0124000D | lower_sensor_limit_help | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value |
0x0124000E | minimum_span_help | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value |
0x0124000F | sensor_serial_number_help | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived |
0x01240011 | upper_range_value_help | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. |
0x01240012 | lower_range_value_help | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. |
0x01240013 | seconds_damping_value_help | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. |
0x01240015 | transmitter_variable_help | Field Device Variable- Digital measurement that changes with respect to time without user intervention |
0x0124001B | final_assembly_number_help | Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device |
0x0124001C | private_label_distributor_help | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers |
0x0124001D | write_protect_mode_help | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. |
0x0124001E | date_help | Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. |
0x0124001F | discriptor_help | Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. |
0x01240020 | message_help | Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. |
0x01240021 | polling_address_help | Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) |
0x01240022 | field_device_identification_help | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. |
0x01240023 | field_device_flags_help | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer |
0x01240024 | physical_signalling_code_help | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port |
0x01240025 | hardware_revision_help | Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device |
0x01240026 | field_device_software_revision_help | Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device |
0x01240027 | field_device_revision_help | Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to |
0x01240028 | universal_revision_help | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to |
0x01240029 | number_of_request_preambles_help | Number of Request Preambles- Number of Preambles required from the Host request by the Field Device |
0x0124002A | manufacturers_device_type_help | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer |
0x0124002B | manufacturer_id_code_help | Manufacturer Identification Code- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device |
0x0124002C | field_device_status_help | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process |
0x0124002D | communications_error_summary_help | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. |
0x0124002E | command_specific_response_code_help | Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. |
0x0124002F | burst_mode_select_help | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. |
0x01240030 | burst_command_number_help | Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled |
0x01240031 | index_into_dynamic_variables_array_help | Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input |
0x01240032 | index_into_dynamic_variables_array_1_help | Index into Dynamic Variables Array- Is the first an array of addresses, whose value is identified by the Field Device Variable Code |
0x01240033 | index_into_dynamic_variables_array_2_help | Index into Dynamic Variables Array- Is the second of an array of addresses, whose value identified by the Field Device Variable Code |
0x01240034 | index_into_dynamic_variables_array_3_help | Index into Dynamic Variables Array- Is the third of an array of addresses, whose value identified by the Field Device Variable Code |
0x01240035 | index_into_dynamic_variables_array_4_help | Index into Dynamic Variables Array- Is the fourth of an array of addresses, whose value identified by the Field Device Variable Code |
0x01240036 | fourth_variable_code_is_help | Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable |
0x01240037 | tertiary_variable_code_is_help | Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable |
0x01240038 | secondary_variable_code_is_help | Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable |
0x01240039 | primary_variable_code_is_help | Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable |
0x0124003A | analog_output_fixed_help | Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. |
0x0124003B | analog_output_saturated_help | Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. |
0x0124003C | operating_mode_2_help | Field Device Specific Operating Mode 2- A possible mode of operation in Field Device |
0x0124003D | operating_mode_1_help | Field Device Specific Operating Mode 1- A possible mode of operation in Field Device |
0x0124003E | index_four_into_analog_output_array_help | Index into Analog Output Array- Is the fourth of an array of addresses, whose value is identified by the Analog Output Code |
0x0124003F | index_three_into_analog_output_array_help | Index into Analog Output Array- Is the third of an array of addresses, whose value is identified by the Analog Output Code |
0x01240040 | index_two_into_analog_output_array_help | Index into Analog Output Array- Is the second of an array of addresses, whose value is identified by the Analog Output Code |
0x01240041 | index_one_into_analog_output_array_help | Index into Analog Output Array- Is the first of an array of addresses, whose value is identified by the Analog Output Code |
0x01240042 | analog_output_number_help | Analog Output Number- Index into an array of Analog Outputs |
0x01240043 | number_of_response_preambles_help | Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host |
0x01240044 | unit_date_help | Field Device Date- Georgian calendar date associated with the Field Device, when there are other Date(s) in the Field Device that relate to sub applications |
0x01240045 | unit_descriptor_help | Field Device Descriptor- Text that is stored in the Field Device, when there are other Descriptors in the Field Device that relate to sub applications |
0x01240046 | unit_tag_help | Field Device Tag- Text that is stored in the Field Device, when there are other Tags in the Field Device that relate to sub applications |
0x01240047 | field_device_status_16_help | Field Device Specific Status Byte 17- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240048 | field_device_status_15_help | Field Device Specific Status Byte 16- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240049 | field_device_status_14_help | Field Device Specific Status Byte 15- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240052 | field_device_status_5_help | Field Device Specific Status Byte 6- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240053 | field_device_status_4_help | Field Device Specific Status Byte 5- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240054 | field_device_status_3_help | Field Device Specific Status Byte 4- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240055 | field_device_status_2_help | Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240056 | field_device_status_1_help | Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240057 | field_device_status_0_help | Field Device Specific Status Byte 1- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240058 | eeprom_select_help | Electrically Erasable Read Only Memory Selection- Controls the data in: EEPROM Read Only Memory / Read Only Memory |
0x01240059 | burn_eeprom_help | Burn Electrically Erasable Read Only Memory- Operation where the Field Device will copy what is in its Random Access Memory into the Electrically Erasable Read Only Memory, thus making changes by the Host permanent |
0x0124005A | leaving_fixed_current_mode_help_1 | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input |
0x0124005B | leaving_fixed_current_mode_help_2 | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output the tracks the input |
0x0124005C | zero_trim_help | Zero trim- Make the sensor input the new zero input reference |
0x0124005D | digital_to_analog_trim_help | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output |
0x0124005E | digital_to_analog_scaled_trim_help | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output |
0x0124005F | fix_analog_output_help | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value |
0x01240060 | applied_values_help | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input |
0x01240061 | loop_test_help | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value |
0x01240062 | tag_help | Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. |
0x01240063 | field_device_status_17_help | Field Device Specific Status Byte 18- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240064 | field_device_status_18_help | Field Device Specific Status Byte 19- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240065 | field_device_status_19_help | Field Device Specific Status Byte 20- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240066 | field_device_status_20_help | Field Device Specific Status Byte 21- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240067 | field_device_status_21_help | Field Device Specific Status Byte 22- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240068 | field_device_status_22_help | Field Device Specific Status Byte 23- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240069 | field_device_status_23_help | Field Device Specific Status Byte 24- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x0124006A | field_device_status_24_help | Field Device Specific Status Byte 25- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240074 | multi_sensor_fld_dev | Multi Sensor Field Device |
0x01240075 | not_write_protected | Not Write Protected |
0x01240076 | write_protected | Write Protected |
0x01240077 | pv_help | Primary Variable |
0x01240078 | percent_rnge_help | Percent of Range of the Primary Variable and Analog Output 1 Current |
0x01240079 | all_process_var_help | All Dynamic Process Variables and Analog Output 1 Current |
0x01260003 | analog_output_1 | AO1 |
0x01260004 | analog_output_2 | AO2 |
0x01260005 | pressure | Pres |
0x01260009 | blank | |
0x01260013 | sensor_unit | Snsr unit |
0x0126001B | cutoff | Cutoff |
0x0126001C | setpoint | Set pt |
0x0126001D | setpoint_units | Set pt unit |
0x0126001E | variable_code | Var code |
0x0126001F | type_code | Typ code |
0x01260055 | analog_output_3 | AO3 |
0x01260056 | analog_output_4 | AO4 |
0x012C0024 | transmitter_variable | Fld dev var |
0x012C0027 | hold_last_output_value | Hold last out valu |
0x012D0001 | remove_loop_from_auto | WARN-Loop should be removed from automatic control |
0x012D0002 | loop_output | Output |
0x012D0003 | fld_dev_otpt_fixed | Fld dev output is fixed at %0 mA |
0x012D0004 | choose_analog_output_level | Choose analog output level |
0x012D0005 | choices_4_20_other_end | 4mA;20mA;Other;End |
0x012D0006 | abort_last_error | Aborting method due to last error |
0x012D0007 | setting_fld_dev_4_ma | Setting fld dev output to 4mA |
0x012D0008 | enter_meter_value | Enter meter value |
0x012D0009 | fld_dev_otpt_equal_ref_meter | Fld dev output %0 mA equal to reference meter? |
0x012D000A | yes_no | Yes;No |
0x012D000B | setting_fld_dev_20_ma | Setting fld dev output to 20mA |
0x012D000C | trim_scaled_from_low_to_high | Trim will be scaled from %{low} to %{high} |
0x012D000D | set_scale_lo_output_value | Set scale- Lo output value |
0x012D000E | set_scale_hi_output_value | Set scale- Hi output value |
0x012D000F | proceed_change | Proceed;Change |
0x012D0010 | high_low_0_invalid | high - low = 0 is invalid |
0x012D0011 | connect_reference_meter | Connect reference meter |
0x012D0012 | scaled_otpt_low_eq_dev | Scaled output: %{low} equal readout device? |
0x012D0013 | scaled_otpt_high_eq_dev | Scaled output: %{high} equal readout device? |
0x012D0014 | this_will_affect_snsr_cal | WARN-This will affect sensor calibration |
0x012D0015 | apply_0_input_to_snsr | Apply 0 input to sensor |
0x012D0016 | snsr_input_stabilizing | Sensor input stabilizing |
0x012D0017 | zero_the_input_and_try_again | Do you wish to zero the input and try again ? |
0x012D0018 | snsr_zero_succeeded | Sensor zero succeeded |
0x012D0019 | return_fld_dev_to_orig_otpt | Returning fld dev to original output |
0x012D001A | loop_may_be_returned_to_auto | NOTE-Loop may be returned to automatic control |
0x012D001B | apply_new_4ma_input | Apply new 4ma input |
0x012D001C | set_the | Set the: |
0x012D001D | choice_4_20_exit | 4mA;20mA;Exit |
0x012D001E | current_applied_process_val | Current applied process value: %{0} %{1} |
0x012D001F | set_4ma_read_new_leave | Set as 4mA value;Read new value;Leave as found |
0x012D0020 | apply_new_20ma_input | Apply new 20ma input |
0x012D0021 | set_20ma_read_new_leave | Set as 20mA value;Read new value;Leave as found |
0x012D0022 | remove_from_auto_befor_send | WARN-Remove loop from automatic control before sending. You may return loop to automatic control after sending. |
0x012D0023 | select_analog_output_to_trim | Select analog output to trim |
0x012D0024 | select_analog_output_units | Select analog output units |
0x012D0025 | select_fld_dev_var_snsr_trim | Select fld dev var sensor to trim |
0x012D0026 | enter_desired_analog_output | Enter desired analog output value |
0x012D0027 | new_value_end | New value;End |
0x012D0028 | fld_dev_AO_is_fixed_at | Feld dev %0 A0 is fixed at %1 %2 |
0x012D0029 | about_to_set_fld_dev_output | About to set fld dev output to %0 %1 |
0x012D002A | fld_dev_output_eq_ref_meter | Fld dev output %0 %1 equal to reference meter? |
0x012D002B | invalid_value_try_again | Invalid value try again |
0x012D002C | making_changes_permanent | Making changes permanent |
0x012D002D | previous_err_seen_brn_eeprom | The previous error was seen while trying to burn EEPROM |
0x012F0041 | fld_dev_stat1_1 | Fld dev stat1-1 |
0x012F0042 | fld_dev_stat1_2 | Fld dev stat1-2 |
0x012F0043 | fld_dev_stat1_3 | Fld dev stat1-3 |
0x012F0044 | fld_dev_stat1_4 | Fld dev stat1-4 |
0x012F0045 | fld_dev_stat1_5 | Fld dev stat1-5 |
0x012F0046 | fld_dev_stat1_6 | Fld dev stat1-6 |
0x012F0047 | fld_dev_stat1_7 | Fld dev stat1-7 |
0x012F0048 | fld_dev_stat1_8 | Fld dev stat1-8 |
0x012F0049 | fld_dev_stat2_1 | Fld dev stat2-1 |
0x012F004A | fld_dev_stat2_2 | Fld dev stat2-2 |
0x012F004B | fld_dev_stat2_3 | Fld dev stat2-3 |
0x012F004C | fld_dev_stat2_4 | Fld dev stat2-4 |
0x012F004D | fld_dev_stat2_5 | Fld dev stat2-5 |
0x012F004E | fld_dev_stat2_6 | Fld dev stat2-6 |
0x012F004F | fld_dev_stat2_7 | Fld dev stat2-7 |
0x012F0050 | fld_dev_stat2_8 | Fld dev stat2-8 |
0x012F0051 | fld_dev_stat3_1 | Fld dev stat3-1 |
0x012F0052 | fld_dev_stat3_2 | Fld dev stat3-2 |
0x012F0053 | fld_dev_stat3_3 | Fld dev stat3-3 |
0x012F0054 | fld_dev_stat3_4 | Fld dev stat3-4 |
0x012F0055 | fld_dev_stat3_5 | Fld dev stat3-5 |
0x012F0056 | fld_dev_stat3_6 | Fld dev stat3-6 |
0x012F0057 | fld_dev_stat3_7 | Fld dev stat3-7 |
0x012F0058 | fld_dev_stat3_8 | Fld dev stat3-8 |
0x012F0059 | fld_dev_stat4_1 | Fld dev stat4-1 |
0x012F005A | fld_dev_stat4_2 | Fld dev stat4-2 |
0x012F005B | fld_dev_stat4_3 | Fld dev stat4-3 |
0x012F005C | fld_dev_stat4_4 | Fld dev stat4-4 |
0x012F005D | fld_dev_stat4_5 | Fld dev stat4-5 |
0x012F005E | fld_dev_stat4_6 | Fld dev stat4-6 |
0x012F005F | fld_dev_stat4_7 | Fld dev stat4-7 |
0x012F0060 | fld_dev_stat4_8 | Fld dev stat4-8 |
0x012F0061 | fld_dev_stat5_1 | Fld dev stat5-1 |
0x012F0062 | fld_dev_stat5_2 | Fld dev stat5-2 |
0x012F0063 | fld_dev_stat5_3 | Fld dev stat5-3 |
0x012F0064 | fld_dev_stat5_4 | Fld dev stat5-4 |
0x012F0065 | fld_dev_stat5_5 | Fld dev stat5-5 |
0x012F0066 | fld_dev_stat5_6 | Fld dev stat5-6 |
0x012F0067 | fld_dev_stat5_7 | Fld dev stat5-7 |
0x012F0068 | fld_dev_stat5_8 | Fld dev stat5-8 |
0x012F0069 | fld_dev_stat6_1 | Fld dev stat6-1 |
0x012F006A | fld_dev_stat6_2 | Fld dev stat6-2 |
0x012F006B | fld_dev_stat6_3 | Fld dev stat6-3 |
0x012F006C | fld_dev_stat6_4 | Fld dev stat6-4 |
0x012F006D | fld_dev_stat6_5 | Fld dev stat6-5 |
0x012F006E | fld_dev_stat6_6 | Fld dev stat6-6 |
0x012F006F | fld_dev_stat6_7 | Fld dev stat6-7 |
0x012F0070 | fld_dev_stat6_8 | Fld dev stat6-8 |
0x012F0071 | fld_dev_stat15_1 | Fld dev stat15-1 |
0x012F0072 | fld_dev_stat15_2 | Fld dev stat15-2 |
0x012F0073 | fld_dev_stat15_3 | Fld dev stat15-3 |
0x012F0074 | fld_dev_stat15_4 | Fld dev stat15-4 |
0x012F0075 | fld_dev_stat15_5 | Fld dev stat15-5 |
0x012F0076 | fld_dev_stat15_6 | Fld dev stat15-6 |
0x012F0077 | fld_dev_stat15_7 | Fld dev stat15-7 |
0x012F0078 | fld_dev_stat15_8 | Fld dev stat15-8 |
0x012F0079 | fld_dev_stat16_1 | Fld dev stat16-1 |
0x012F007A | fld_dev_stat16_2 | Fld dev stat16-2 |
0x012F007B | fld_dev_stat16_3 | Fld dev stat16-3 |
0x012F007C | fld_dev_stat16_4 | Fld dev stat16-4 |
0x012F007D | fld_dev_stat16_5 | Fld dev stat16-5 |
0x012F007E | fld_dev_stat16_6 | Fld dev stat16-6 |
0x012F007F | fld_dev_stat16_7 | Fld dev stat16-7 |
0x012F0080 | fld_dev_stat16_8 | Fld dev stat16-8 |
0x012F0081 | fld_dev_stat17_1 | Fld dev stat17-1 |
0x012F0082 | fld_dev_stat17_2 | Fld dev stat17-2 |
0x012F0083 | fld_dev_stat17_3 | Fld dev stat17-3 |
0x012F0084 | fld_dev_stat17_4 | Fld dev stat17-4 |
0x012F0085 | fld_dev_stat17_5 | Fld dev stat17-5 |
0x012F0086 | fld_dev_stat17_6 | Fld dev stat17-6 |
0x012F0087 | fld_dev_stat17_7 | Fld dev stat17-7 |
0x012F0088 | fld_dev_stat17_8 | Fld dev stat17-8 |
0x012F0089 | fld_dev_stat18_1 | Fld dev stat18-1 |
0x012F008A | fld_dev_stat18_2 | Fld dev stat18-2 |
0x012F008B | fld_dev_stat18_3 | Fld dev stat18-3 |
0x012F008C | fld_dev_stat18_4 | Fld dev stat18-4 |
0x012F008D | fld_dev_stat18_5 | Fld dev stat18-5 |
0x012F008E | fld_dev_stat18_6 | Fld dev stat18-6 |
0x012F008F | fld_dev_stat18_7 | Fld dev stat18-7 |
0x012F0090 | fld_dev_stat18_8 | Fld dev stat18-8 |
0x012F0091 | fld_dev_stat19_1 | Fld dev stat19-1 |
0x012F0092 | fld_dev_stat19_2 | Fld dev stat19-2 |
0x012F0093 | fld_dev_stat19_3 | Fld dev stat19-3 |
0x012F0094 | fld_dev_stat19_4 | Fld dev stat19-4 |
0x012F0095 | fld_dev_stat19_5 | Fld dev stat19-5 |
0x012F0096 | fld_dev_stat19_6 | Fld dev stat19-6 |
0x012F0097 | fld_dev_stat19_7 | Fld dev stat19-7 |
0x012F0098 | fld_dev_stat19_8 | Fld dev stat19-8 |
0x012F0099 | fld_dev_stat20_1 | Fld dev stat20-1 |
0x012F009A | fld_dev_stat20_2 | Fld dev stat20-2 |
0x012F009B | fld_dev_stat20_3 | Fld dev stat20-3 |
0x012F009C | fld_dev_stat20_4 | Fld dev stat20-4 |
0x012F009D | fld_dev_stat20_5 | Fld dev stat20-5 |
0x012F009E | fld_dev_stat20_6 | Fld dev stat20-6 |
0x012F009F | fld_dev_stat20_7 | Fld dev stat20-7 |
0x012F00A0 | fld_dev_stat20_8 | Fld dev stat20-8 |
0x012F00A1 | fld_dev_stat21_1 | Fld dev stat21-1 |
0x012F00A2 | fld_dev_stat21_2 | Fld dev stat21-2 |
0x012F00A3 | fld_dev_stat21_3 | Fld dev stat21-3 |
0x012F00A4 | fld_dev_stat21_4 | Fld dev stat21-4 |
0x012F00A5 | fld_dev_stat21_5 | Fld dev stat21-5 |
0x012F00A6 | fld_dev_stat21_6 | Fld dev stat21-6 |
0x012F00A7 | fld_dev_stat21_7 | Fld dev stat21-7 |
0x012F00A8 | fld_dev_stat21_8 | Fld dev stat21-8 |
0x012F00A9 | fld_dev_stat22_1 | Fld dev stat22-1 |
0x012F00AA | fld_dev_stat22_2 | Fld dev stat22-2 |
0x012F00AB | fld_dev_stat22_3 | Fld dev stat22-3 |
0x012F00AC | fld_dev_stat22_4 | Fld dev stat22-4 |
0x012F00AD | fld_dev_stat22_5 | Fld dev stat22-5 |
0x012F00AE | fld_dev_stat22_6 | Fld dev stat22-6 |
0x012F00AF | fld_dev_stat22_7 | Fld dev stat22-7 |
0x012F00B0 | fld_dev_stat22_8 | Fld dev stat22-8 |
0x012F00B1 | fld_dev_stat23_1 | Fld dev stat23-1 |
0x012F00B2 | fld_dev_stat23_2 | Fld dev stat23-2 |
0x012F00B3 | fld_dev_stat23_3 | Fld dev stat23-3 |
0x012F00B4 | fld_dev_stat23_4 | Fld dev stat23-4 |
0x012F00B5 | fld_dev_stat23_5 | Fld dev stat23-5 |
0x012F00B6 | fld_dev_stat23_6 | Fld dev stat23-6 |
0x012F00B7 | fld_dev_stat23_7 | Fld dev stat23-7 |
0x012F00B8 | fld_dev_stat23_8 | Fld dev stat23-8 |
0x012F00B9 | fld_dev_stat24_1 | Fld dev stat24-1 |
0x012F00BA | fld_dev_stat24_2 | Fld dev stat24-2 |
0x012F00BB | fld_dev_stat24_3 | Fld dev stat24-3 |
0x012F00BC | fld_dev_stat24_4 | Fld dev stat24-4 |
0x012F00BD | fld_dev_stat24_5 | Fld dev stat24-5 |
0x012F00BE | fld_dev_stat24_6 | Fld dev stat24-6 |
0x012F00BF | fld_dev_stat24_7 | Fld dev stat24-7 |
0x012F00C0 | fld_dev_stat24_8 | Fld dev stat24-8 |
0x012F00C1 | fld_dev_stat25_1 | Fld dev stat25-1 |
0x012F00C2 | fld_dev_stat25_2 | Fld dev stat25-2 |
0x012F00C3 | fld_dev_stat25_3 | Fld dev stat25-3 |
0x012F00C4 | fld_dev_stat25_4 | Fld dev stat25-4 |
0x012F00C5 | fld_dev_stat25_5 | Fld dev stat25-5 |
0x012F00C6 | fld_dev_stat25_6 | Fld dev stat25-6 |
0x012F00C7 | fld_dev_stat25_7 | Fld dev stat25-7 |
0x012F00C8 | fld_dev_stat25_8 | Fld dev stat25-8 |
0x012F00C9 | ao1_out_rnge_lim | AO1 Out rnge lim |
0x012F00CA | ao2_out_rnge_lim | AO2 Out rnge lim |
0x012F00CB | ao3_out_rnge_lim | AO3 Out rnge lim |
0x012F00CC | ao4_out_rnge_lim | AO4 Out rnge lim |
0x012F00CD | ao5_out_rnge_lim | AO5 Out rnge lim |
0x012F00CE | ao6_out_rnge_lim | AO6 Out rnge lim |
0x012F00CF | ao7_out_rnge_lim | AO7 Out rnge lim |
0x012F00D0 | ao8_out_rnge_lim | AO8 Out rnge lim |
0x012F00D1 | ao9_out_rnge_lim | AO9 Out rnge lim |
0x012F00D2 | ao10_out_rnge_lim | AO10 Out rnge lim |
0x012F00D3 | ao11_out_rnge_lim | AO11 Out rnge lim |
0x012F00D4 | ao12_out_rnge_lim | AO12 Out rnge lim |
0x012F00D5 | ao13_out_rnge_lim | AO13 Out rnge lim |
0x012F00D6 | ao14_out_rnge_lim | AO14 Out rnge lim |
0x012F00D7 | ao15_out_rnge_lim | AO15 Out rnge lim |
0x012F00D8 | ao16_out_rnge_lim | AO16 Out rnge lim |
0x012F00D9 | ao17_out_rnge_lim | AO17 Out rnge lim |
0x012F00DA | ao18_out_rnge_lim | AO18 Out rnge lim |
0x012F00DB | ao19_out_rnge_lim | AO19 Out rnge lim |
0x012F00DC | ao20_out_rnge_lim | AO20 Out rnge lim |
0x012F00DD | ao21_out_rnge_lim | AO21 Out rnge lim |
0x012F00DE | ao22_out_rnge_lim | AO22 Out rnge lim |
0x012F00DF | ao23_out_rnge_lim | AO23 Out rnge lim |
0x012F00E0 | ao24_out_rnge_lim | AO24 Out rnge lim |
0x012F00E1 | ao1_in_fixed_mode | AO1 In fixed mode |
0x012F00E2 | ao2_in_fixed_mode | AO2 In fixed mode |
0x012F00E3 | ao3_in_fixed_mode | AO3 In fixed mode |
0x012F00E4 | ao4_in_fixed_mode | AO4 In fixed mode |
0x012F00E5 | ao5_in_fixed_mode | AO5 In fixed mode |
0x012F00E6 | ao6_in_fixed_mode | AO6 In fixed mode |
0x012F00E7 | ao7_in_fixed_mode | AO7 In fixed mode |
0x012F00E8 | ao8_in_fixed_mode | AO8 In fixed mode |
0x012F00E9 | ao9_in_fixed_mode | AO9 In fixed mode |
0x012F00EA | ao10_in_fixed_mode | AO10 In fixed mode |
0x012F00EB | ao11_in_fixed_mode | AO11 In fixed mode |
0x012F00EC | ao12_in_fixed_mode | AO12 In fixed mode |
0x012F00ED | ao13_in_fixed_mode | AO13 In fixed mode |
0x012F00EE | ao14_in_fixed_mode | AO14 In fixed mode |
0x012F00EF | ao15_in_fixed_mode | AO15 In fixed mode |
0x012F00F0 | ao16_in_fixed_mode | AO16 In fixed mode |
0x012F00F1 | ao17_in_fixed_mode | AO17 In fixed mode |
0x012F00F2 | ao18_in_fixed_mode | AO18 In fixed mode |
0x012F00F3 | ao19_in_fixed_mode | AO19 In fixed mode |
0x012F00F4 | ao20_in_fixed_mode | AO20 In fixed mode |
0x012F00F5 | ao21_in_fixed_mode | AO21 In fixed mode |
0x012F00F6 | ao22_in_fixed_mode | AO22 In fixed mode |
0x012F00F7 | ao23_in_fixed_mode | AO23 In fixed mode |
0x012F00F8 | ao24_in_fixed_mode | AO24 In fixed mode |
0x01310001 | inches_of_water_68_degrees_F_help | Inches of Water at 68 Degrees Fahrenheit |
0x01310002 | inches_of_mercury_0_degrees_C_help | Inches of Mercury at 0 Degrees Celsius |
0x01310003 | feet_of_water_68_degrees_F_help | Feet of Water at 68 Degrees Fahrenheit |
0x01310004 | millimeters_of_water_68_degrees_F_help | Millimeters of Water at 68 Degrees Fahrenheit |
0x01310005 | millimeters_of_mercury_0_degrees_C_help | Millimeters of Mercury at 0 Degrees Celsius |
0x01310006 | pounds_per_square_inch_help | Pounds Per Square Inch |
0x01310007 | bars_help | Bars |
0x01310008 | millibars_help | Millibars |
0x01310009 | grams_per_square_centimeter_help | Grams Per Square Centimeter |
0x0131000A | kilograms_per_square_centimeter_help | Kilograms Per Square Centimeter |
0x0131000B | pascals_help | Pascals |
0x0131000C | kilopascals_help | Kilopascals |
0x0131000D | torr_help | Torr @ 0 Degrees Celsius |
0x0131000E | atmospheres_help | Atmospheres |
0x0131000F | cubic_feet_per_minute_help | Cubic Feet Per Minute |
0x01310010 | gallons_per_minute_help | Gallons Per Minute |
0x01310011 | liters_per_minute_help | Liters Per Minute |
0x01310012 | imperial_gallons_per_minute_help | Imperial Gallons Per Minute |
0x01310013 | cubic_feet_per_hour_help | Cubic Feet Per Hour |
0x01310014 | feet_per_second_help | Feet Per Second |
0x01310015 | meters_per_second_help | Meters Per Second |
0x01310016 | gallons_per_second_help | Gallons Per Second |
0x01310017 | million_gallons_per_day_help | Million Gallons Per Day |
0x01310018 | liters_per_second_help | Liters Per Second |
0x01310019 | million_liters_per_day_help | Million Liters Per Day |
0x0131001A | cubic_feet_per_second_help | Cubic Feet Per Second |
0x0131001B | cubic_feet_per_day_help | Cubic Feet Per Day |
0x0131001C | cubic_meters_per_second_help | Cubic Meters Per Second |
0x0131001D | cubic_meters_per_day_help | Cubic Meters Per Day |
0x0131001E | imperial_gallons_per_hour_help | Imperial Gallons Per Hour |
0x0131001F | imperial_gallons_per_day_help | Imperial Gallons Per Day |
0x01310020 | degrees_celsius_help | Degrees Celsius |
0x01310021 | degrees_fahrenheit_help | Degrees Fahrenheit |
0x01310022 | degrees_rankine_help | Degrees Rankine |
0x01310023 | degrees_kelvin_help | Degrees Kelvin |
0x01310024 | millivolts_help | Millivolts |
0x01310025 | ohms_help | Ohms |
0x01310026 | hertz_help | Hertz |
0x01310027 | milliamperes_help | Milliamperes |
0x01310028 | gallons_help | Gallons |
0x01310029 | liters_help | Liters |
0x0131002A | imperial_gallons_help | Imperial Gallons |
0x0131002B | cubic_meters_help | Cubic Meters |
0x0131002C | feet_help | Feet |
0x0131002D | meters_help | Meters |
0x0131002E | barrels_help | Barrels |
0x0131002F | inches_help | Inches |
0x01310030 | centimeters_help | Centimeters |
0x01310031 | millimeters_help | Millimeters |
0x01310032 | minutes_help | Minutes |
0x01310033 | seconds_help | Seconds |
0x01310034 | hours_help | Hours |
0x01310035 | days_help | Days |
0x01310036 | centistokes_help | Centistokes |
0x01310037 | centipoise_help | Centipoise |
0x01310038 | microsiemens_help | Microsiemens |
0x01310039 | percent_help | Percent |
0x0131003A | volts_help | Volts |
0x0131003B | pH_help | pH |
0x0131003C | grams_help | Grams |
0x0131003D | kilograms_help | Kilograms |
0x0131003E | metric_tons_help | Metric Tons |
0x0131003F | pounds_help | Pounds |
0x01310040 | short_tons_help | Short Tons (2000 Pounds) |
0x01310041 | long_tons_help | Long Tons (2240 Pounds) |
0x01310042 | grams_per_second_help | Grams Per Second |
0x01310043 | grams_per_minute_help | Grams Per Minute |
0x01310044 | grams_per_hour_help | Grams Per Hour |
0x01310045 | kilograms_per_second_help | Kilograms Per Second |
0x01310046 | kilograms_per_minute_help | Kilograms Per Minute |
0x01310047 | kilograms_per_hour_help | Kilograms Per Hour |
0x01310048 | kilograms_per_day_help | Kilograms Per Day |
0x01310049 | metric_tons_per_minute_help | Metric Tons Per Minute |
0x0131004A | metric_tons_per_hour_help | Metric Tons Per Hour |
0x0131004B | metric_tons_per_day_help | Metric Tons Per Day |
0x0131004C | pounds_per_second_help | Pounds Per Second |
0x0131004D | pounds_per_minute_help | Pounds Per Minute |
0x0131004E | pounds_per_hour_help | Pounds Per Hour |
0x0131004F | pounds_per_day_help | Pounds Per Day |
0x01310050 | short_tons_per_minute_help | Short Tons (2000 Pounds) Per Minute |
0x01310051 | short_tons_per_hour_help | Short Tons (2000 Pounds) Per Hour |
0x01310052 | short_tons_per_day_help | Short Tons (2000 Pounds) Per Day |
0x01310053 | long_tons_per_hour_help | Long Tons (2240 Pounds) Per Hour |
0x01310054 | long_tons_per_day_help | Long Tons (2240 Pounds) Per Day |
0x01310055 | specific_gravity_units_help | Specific Gravity Units |
0x01310056 | grams_per_cubic_centimeter_help | Grams Per Cubic Centimeter |
0x01310057 | kilograms_per_cubic_meter_help | Kilograms Per Cubic Meter |
0x01310058 | pounds_per_gallon_help | Pounds Per Gallon |
0x01310059 | pounds_per_cubic_foot_help | Pounds Per Cubic Foot |
0x0131005A | grams_per_milliliter_help | Grams Per Milliliter |
0x0131005B | kilograms_per_liter_help | Kilograms Per liter |
0x0131005C | grams_per_liter_help | Grams Per Liter |
0x0131005D | pounds_per_cubic_inch_help | Pounds Per Cubic Inch |
0x0131005E | short_tons_per_cubic_yard_help | Short Tons (2000 Pounds) Per Cubic Yard |
0x0131005F | degrees_twaddell_help | Degrees Twaddell |
0x01310060 | degrees_brix_help | Degrees Brix |
0x01310061 | degrees_baume_heavy_help | Degrees Baume - Heavy |
0x01310062 | degrees_baume_light_help | Degrees Baume - Light |
0x01310063 | degrees_API_help | Degrees API |
0x01310064 | percent_solids_per_weight_help | Percent Solids Per Weight |
0x01310065 | percent_solids_per_volume_help | Percent Solids Per Volume |
0x01310066 | degrees_balling_help | Degrees Balling |
0x01310067 | proof_per_volume_help | Proof Per Volume |
0x01310068 | proof_per_mass_help | Proof Per Mass |
0x01310069 | bushels_help | Bushels |
0x0131006A | cubic_yards_help | Cubic Yards |
0x0131006B | cubic_feet_help | Cubic Feet |
0x0131006C | cubic_inches_help | Cubic Inches |
0x0131006D | meters_per_hour_help | Meters Per Hour |
0x0131006E | cubic_meter_per_hour_help | Cubic Meter Per Hour |
0x0131006F | cubic_meters_per_minute_help | Cubic Meters Per Minute |
0x01310070 | barrels_per_second_help | Barrels Per Second |
0x01310071 | barrels_per_minute_help | Barrels Per Minute |
0x01310072 | barrels_per_hour_help | Barrels Per Hour |
0x01310073 | barrels_per_day_help | Barrels Per Day |
0x01310074 | gallons_per_hour_help | Gallons Per Hour |
0x01310075 | imperial_gallons_per_second_help | Imperial Gallons Per Second |
0x01310076 | liters_per_hour_help | Liters Per Hour |
0x01310077 | percent_steam_quality_help | Percent Steam Quality |
0x01310079 | cubic_feet_per_pound_help | Cubic Feet Per Pound |
0x0131007A | picofarads_help | Picofarads |
0x0131007B | percent_plato_help | Percent Plato |
0x0131007C | gallons_per_day_help | Gallons Per Day |
0x0131007D | hectoliters_help | Hectoliters |
0x0131007E | megapascals_help | Megapascals |
0x0131007F | inches_of_water_4_degrees_C_help | Inches of Water at 4 Degrees Celsius |
0x01310080 | millimeters_of_water_4_degrees_C_help | Millimeters of Water at 4 Degrees Celsius |
0x01310081 | carbon_steel_help | Carbon Steel |
0x01310082 | stainless_steel_304_help | 304 Stainless Steel |
0x01310083 | stainless_steel_316_help | 316 Stainless Steel |
0x01310084 | hastelloy_c_help | Hastelloy C |
0x01310085 | monel_help | Monel |
0x01310086 | tantalum_help | Tantalum |
0x01310087 | titanium_help | Titanium |
0x01310088 | platinum_iridium_help | Platinum-Iridium |
0x01310089 | alloy_20_help | Alloy 20 |
0x0131008A | cobalt_chromium_nickel_help | Cobalt-Chromium-Nickel |
0x0131008B | ptfe_teflon_help | PTFE(Teflon) |
0x0131008C | viton_help | Viton |
0x0131008D | buna_n_help | Buna-N |
0x0131008E | ethyl_prop_help | Ethyl-Prop |
0x0131008F | urethane_help | Urethane |
0x01310091 | tefzel_help | Tefzel |
0x01310092 | ryton_help | Ryton |
0x01310093 | ceramic_help | Ceramic |
0x01310094 | stainless_steel_316l_help | 316L Stainless Steel |
0x01310095 | pvc_help | PVC |
0x01310096 | nitrile_rubber_help | Nitrile Rubber |
0x01310097 | kalrez_help | Kalrez |
0x01310098 | inconel_help | Inconel |
0x01310099 | kynar_help | Kynar |
0x0131009A | aluminum_help | Aluminum |
0x0131009B | nickel_help | Nickel |
0x0131009C | hastelloy_c_276_help | Hastelloy C 276 |
0x0131009D | monel_400_help | Monel 400 |
0x0131009E | linear_help | Linear |
0x0131009F | square_root_help | Square root |
0x013100A0 | square_root_third_power_help | Square Root to the Third Power |
0x013100A1 | square_root_fifth_power_help | Square Root to the Fifth Power |
0x013100A2 | special_curve_help | Special curve |
0x013100A3 | square_root_plus_special_curve_help | Square Root Plus Special Curve |
0x013100A4 | square_root_third_power_plus_special_curve_help | Square Root to the Third Power Plus Special Curve |
0x013100A5 | square_root_fifth_power_plus_special_curve_help | Square Root to the Fifth Power Plus Special Curve |
0x013100A6 | high_help | High |
0x013100A7 | low_help | Low |
0x013100A8 | hold_last_output_value_help | Hold Last Output Value |
0x013100A9 | analog_output_1_help | Analog Output 1 |
0x013100AA | analog_output_2_help | Analog Output 2 |
0x013100AB | analog_output_3_help | Analog Output 3 |
0x013100AC | analog_output_4_help | Analog Output 4 |
0x013100AD | bbl_liq_help | Liquid barrel |
0x013100AE | ounce_help | Ounce of weight, on Earth (Avoirdupois) |
0x013100AF | foot_pound_force_help | Foot pound force |
0x013100B0 | kilo_watt_help | Kilo watts |
0x013100B1 | kilo_watt_hour_help | Kilo watt hours |
0x013100B2 | horsepower_help | UK Horsepower (550 ft lbf/s) |
0x013100B3 | mega_calorie_help | Mega calories |
0x013100B4 | mega_joule_help | Mega Joules |
0x013100B5 | british_thermal_unit_help | British thermal unit |
0x013100B6 | normal_cubic_meter_help | Normal cubic meter (at 273.15 degrees Kelvin, 101.325 kilopascals) |
0x013100B7 | normal_liter_help | Normal liters (at 273.15 degrees Kelvin, 101.325 kilopascals) |
0x013100B8 | standard_cubic_feet_help | Cubic feet (at 32 degrees Fahrenheit, 1 Atmosphere) |
0x013100B9 | mega_calorie_per_hour_help | Mega calories per hour |
0x013100BA | mega_joule_per_hour_help | Mega Joules per hour |
0x013100BB | british_thermal_unit_per_hour_help | British thermal unit per hour |
0x013100BC | normal_cubic_meter_per_hour_help | Normal cubic meters (at 273.15 degrees Kelvin, 101.325 kilopascals) per hour |
0x013100BD | normal_liter_per_hour_help | Normal liters (at 273.15 degrees Kelvin, 101.325 kilo pascals)per hour |
0x013100BE | standard_cubic_feet_per_minute_help | Cubic feet (at 32 degrees Fahrenheit, 1 Atmosphere) per minute |
0x013100BF | deka_therm_help | Deka therm. |
0x013100C0 | parts_per_million_help | Parts per million |
0x013100C1 | fep_help | Perfluoraethylenpropylene |
0x013100C2 | stainless_steel_316_ti_help | 316 Stainless steel Ti, 16-18% Chromium, 10-14% Nickel, 2-3% Molybdan |
0x013100C3 | rs_232_help | Standards designation |
0x013100C4 | gold_monel_help | Gold monel alloy |
0x013100C5 | milli_siemens_per_centimeter_help | milli siemens per centimeter |
0x013100C6 | kohms_help | Kilo ohms |
0x013100C7 | klinger_c4401_help | 4401- Material that may be referenced by Klinger compound No. C4401 |
0x013100C8 | thermotork_help | Thermotork- Material trademarked by Armstrong World Industries Inc. |
0x013100C9 | grafoil_help | Grafoil- Material trademarked by Union Carbide |
0x013100CA | ptfe_coated_316l_sst_help | Poly Tetra Fluoro Ethylene coated 316L Stainless steel- Material, PTFE is also known by the trademark name Teflon |
0x013100CB | gold_plated_hastelloy_c276_help | Gold plated Hastelloy C276- Material |
0x013100CC | ptfe_graphite_help | Poly Tetra Fluoro Ethylene Graphite- Material, Graphite filled PTFE, PTFE is also known by the trademark name Teflon |
0x013100CD | ptfe_glass_help | Poly Tetra Fluoro Ethylene Glass- Material, Glass filled PTFE, PTFE is also known by the trademark name Teflon |
0x013100CE | micro_siemens_per_centimeter_help | Micro siemens per centimeter |
0x013100CF | newton_help | Newton- Unit of force |
0x013100D0 | newton_meter_help | Newton meter- Unit for torque |
0x013100D1 | inches_per_second_help | Inches per Second- Unit for speed |
0x013100D2 | inches_per_minute_help | Inches per minute- Unit for speed |
0x013100D3 | feet_per_minute_help | Feet per Minute- Unit for speed |
0x013100D4 | degrees_per_second_help | Degrees per Second- Unit for angular frequency |
0x013100D5 | revolutions_per_minute_help | Revolutions per Minute- Unit for rotation |
0x013100D6 | degrees_help | Degrees- Unit of angular measurement |
0x013100D7 | revolutions_per_second_help | Revolutions per Second- Unit for rotation |
0x013100D8 | square_help | Square |
0x013100D9 | PTFE_hastelloy_help | Poly Tetra Fluoro Ethylene/Hastelloy- Type of O-Ring material, known as Turcon Variseal H. |
0x013100DA | stainless_steel_CF_8M_help | Stainless Steel CF-8M |
0x013100DB | hastelloy_sst_help | Hastelloy C/Stainless Steel |
0x013100DC | gold_plated_sst_help | Gold Plated Stainless Steel |
0x013100DD | radian_help | Radian- Unit of angular measurement |
0x013100DE | inches_of_water_60_degrees_F_help | Inches of Water at 60 Degrees Fahrenheit |
0x013100DF | ug_l_help | Micrograms per Liter |
0x013100E0 | ug_m3_help | Micrograms per Cubic Meter |
0x013100E1 | percent_consistency_help | Percent Consistency |
0x013100E2 | volume_percent_help | Volume Percent |
0x013100E3 | ml_l_help | Mililiters per Liter |
0x013100E4 | ul_l_help | Microliters per Liter |
0x013100E5 | percent_lel_help | Percent Lower Explosion Level |
0x013100E6 | ppb_help | Parts per Billion |
0x013100E7 | discrete_switch_help | Discrete (Switch)- binary on/off |
0x013100E8 | aflas_help | Aflas |
0x01900003 | default_label | No Label Available |
0x01910001 | hart_block_label | |
0x332C0000 | mmi_pressure_label | Pressure |
0x332C0001 | mmi_event1_label | Event 1 |
0x332C000A | mmi_event2_label | Event 2 |
0x332C0013 | mmi_flange_label | Flange |
0x332C0014 | mmi_base_mass_unit_label | Base mass unit |
0x332C0015 | mmi_base_mass_time_label | Base mass time |
0x332C0016 | mmi_mass_flow_conv_label | Mass flo conv factr |
0x332C0017 | mmi_mass_flow_text_label | Mass flo text |
0x332C0018 | mmi_mass_total_text_label | Mass totl text |
0x332C0019 | mmi_base_vol_unit_label | Base vol unit |
0x332C001A | mmi_base_vol_time_label | Base vol time |
0x332C001B | mmi_vol_flow_conv_label | Vol flo conv factr |
0x332C001C | mmi_vol_flow_text_label | Vol flo text |
0x332C001D | mmi_vol_total_text_label | Vol totl text |
0x332C001E | mmi_slug_high_label | Slug high limit |
0x332C001F | mmi_slug_low_label | Slug low limit |
0x332C0020 | mmi_flocal_label | FlowCal |
0x332C0021 | mmi_pv_ao_cutoff_label | PV AO cutoff |
0x332C0023 | mmi_ao_cutoff_label | AO cutoff |
0x332C0024 | mmi_zero_time_label | Zero time |
0x332C0025 | mmi_max_pulse_width_label | Max pulse width |
0x332C0027 | mmi_temp_cal_label | Temp cal factr |
0x332C0028 | mmi_zero_unit_label | Zero units |
0x332C0029 | mmi_std_dev_label | Std dev |
0x332C002A | mmi_slug_dur_label | Slug duration |
0x332C002B | mmi_ref_temp_label | Ref temperature |
0x332C002C | mmi_k1_label | K1 |
0x332C002D | mmi_k2_label | K2 |
0x332C002E | mmi_dcoef_label | Temp coeff |
0x332C002F | mmi_alarm_num_label | Event num |
0x332C0030 | mmi_event1_type_label | Event1 type |
0x332C0031 | mmi_event2_type_label | Event2 type |
0x332C0032 | mmi_event1_setpoint_label | Event1 setpoint |
0x332C0033 | mmi_event2_setpoint_label | Event2 setpoint |
0x332C0034 | mmi_event1_var_label | Event1 var |
0x332C0035 | mmi_event2_var_label | Event2 var |
0x332C0036 | mmi_pres_freq_label | Pres freq |
0x332C0037 | mmi_qv_is_label | QV is |
0x332C0039 | mmi_pulses_unit_label | Pulses/Unit |
0x332C003A | mmi_units_pulse_label | Units/Pulse |
0x332C003C | mmi_fo_scaling_label | FO Scale Method |
0x332C003D | mmi_freq_flow_label | Freq=Flow |
0x332C003E | mmi_dens_tgco_label | DTG |
0x332C003F | mmi_dens_fqco1_label | DFQ1 |
0x332C0040 | mmi_dens_fqco2_label | DFQ2 |
0x332C0041 | mmi_flow_tgco_label | FTG |
0x332C0042 | mmi_flow_fqco_label | FFQ |
0x332C0046 | mmi_value_label | Value |
0x332C0048 | mmi_low_alarm_label | Low Alarm |
0x332C005F | mmi_rs485_protocol_label | RS485 Protocol |
0x332C0060 | mmi_rs485_baudrate_label | RS485 Baudrate |
0x332C0061 | mmi_rs485_parity_label | RS485 Parity |
0x332C0062 | mmi_rs485_stop_label | RS485 Stop Bits |
0x332C0063 | mmi_ao1_fault_setup_label | AO1 Fault Setup |
0x332C0064 | mmi_fo_fault_setup_label | FO Fault Setup |
0x332C0065 | mmi_dig_comm_fault_setup_label | Dig. Comm Fault Setup |
0x332C0066 | mmi_flow_pres_factor_label | Flow factr |
0x332C0067 | mmi_dens_pres_factor_label | Dens factr |
0x332C0068 | mmi_zero_pres_factor_label | Flowcal pressure |
0x332C006B | mmi_fo_fault_level_label | FO Fault Value |
0x332C006C | mmi_pres_comp_label | Pressure Comp. |
0x332C006D | mmi_fcf_label | FCF |
0x332C006E | mmi_dt_label | DT |
0x332C0070 | mmi_fo_fault_label | FO Fault indicator |
0x332C0071 | mmi_rs485_fault_label | Comm Fault ind. |
0x332C0072 | mmi_tube_freq_var_label | Tube Frequency |
0x332C0073 | mmi_drive_gain_var_label | Drive Gain |
0x332C0075 | mmi_board_temp_var_label | Board Temperature |
0x332C0077 | mmi_abs_val_label | Absolute Value |
0x332C0079 | mmi_scaled_dac_label | Scaled AO1 trim |
0x332C007A | mmi_case_temp_var_label | Meter Temp: T-Series |
0x332C007B | mmi_poll_xmtr_tag_1 | Ext Dev Tag 1 |
0x332C007C | mmi_poll_xmtr_tag_2 | Ext Dev Tag 2 |
0x332C007D | mmi_polling_labl_1 | Poll Control 1 |
0x332C007E | mmi_polling_labl_2 | Poll Control 2 |
0x332C007F | mmi_poll_var1_label | Polled Var 1 |
0x332C0080 | mmi_poll_var2_label | Polled Var 2 |
0x332C0081 | mmi_poll_type_label | Polling Type |
0x332C0082 | mmi_iso_brd_label | IS Output |
0x332C0083 | mmi_update_rate_var_label | Update rate var |
0x332C008A | mmi_ma1_fault_level_label | mA1 Fault Value |
0x332C008C | mmi_ao1_fault_label | AO1 Fault indicator |
0x332C008D | mmi_ao2_fault_label | AO2 Fault indicator |
0x332C0090 | mmi_drive_value_unit | Drive unit |
0x332C00A3 | mmi_fo_mode_label | Mode |
0x332C00A4 | mmi_single_label | Single |
0x332C00A5 | mmi_quadrature_label | Quadrature |
0x332C00A6 | mmi_dual0shift_label | Dual with 0 degrees phase shift |
0x332C00A7 | mmi_dual180shift_label | Dual with 180 degrees phase shift |
0x332C00A8 | mmi_dual90shift_label | Dual with 90 degrees phase shift |
0x332C00A9 | mmi_dualminus90shift_label | Dual with -90 degrees phase shift |
0x332C00B7 | mmi_polarity_label | Polarity |
0x332C00B8 | mmi_active_high_label | Active High |
0x332C00B9 | mmi_active_low_label | Active Low |
0x332C00BA | mmi_enable_pres_comp_label | Enable Pressure Comp |
0x332C00BB | mmi_static_pressure_label | Static Pressure |
0x332C00BD | mmi_enable_extern_temp_label | Enable Ext Temp |
0x332C00BE | mmi_static_temp_label | Static Temperature |
0x332C00BF | mmi_extern_temp_label | Ext Temp |
0x332C00C0 | mmi_cfg_brd_label | Config I/O |
0x332C00EF | mmi_2500_cfg_brd_label | 2500 Config I/O |
0x332C00F0 | mmi_3500_brd_label | 3000 |
0x332C00F1 | mmi_var_assignment_label | Var Assignment |
0x332C010A | mmi_neg_forward_only_label | Negate/Forward Only |
0x332C010B | mmi_neg_bidir_label | Negate/Bi-Directional |
0x332C010C | mmi_burst_var_1_label | Burst Var 1 |
0x332C010D | mmi_burst_var_2_label | Burst Var 2 |
0x332C010E | mmi_burst_var_3_label | Burst Var 3 |
0x332C010F | mmi_burst_var_4_label | Burst Var 4 |
0x332C0110 | mmi_modbus_address_label | Modbus Address |
0x332C0111 | mmi_num_preambles_label | Num Preambles |
0x332D0000 | mmi_cal_perform_label | Perform Cal |
0x332D0001 | mmi_fix_ao1_label | Fix Analog Out 1 |
0x332D0003 | mmi_trim_ao1_label | Trim Analog Out 1 |
0x332D0005 | mmi_ev1_stat_label | Status Event1 |
0x332D0006 | mmi_ev2_stat_label | Status Event2 |
0x332D0007 | mmi_view_stat_label | View status |
0x332D0008 | mmi_start_total_label | Start totalizer |
0x332D0009 | mmi_stop_total_label | Stop totalizer |
0x332D000B | mmi_str_pv_assign | NOTE-Send PV assignment before modifying range values. |
0x332D000C | mmi_str_sv_assign | NOTE-Send SV assignment before modifying range values. |
0x332D000D | mmi_str_tv_assign | NOTE-Send TV assignment before modifying frequency scaling. |
0x332D000F | mmi_str_stat_no_prob | No Device Problems seen during Selftest |
0x332D0010 | mmi_str_enter_dens | Enter Density |
0x332D0011 | mmi_str_cal_in_prog | Calibration in Progress... |
0x332D0012 | mmi_str_prob_detected | A problem was detected |
0x332D0013 | mmi_str_abort_fix_retry | Abort;Fix and Retry |
0x332D0014 | mmi_str_zero_fail | Auto Zero Failed |
0x332D0015 | mmi_str_perform_cal | Perform calibration? |
0x332D0016 | mmi_str_dens_cal_complete | Density Calibration Complete |
0x332D0017 | mmi_str_auto_loop | WARN-Loop should be removed from automatic control |
0x332D0018 | mmi_str_freq_level | Choose frequency output level |
0x332D0019 | mmi_str_freq_choice | 10 kHz;Other;End |
0x332D001A | mmi_str_output_is | Output |
0x332D001B | mmi_str_abort_error | Aborting due to field device error |
0x332D001C | mmi_str_freq_fixed | Frequency output is fixed at %0 Hz |
0x332D001D | mmi_str_anal_level | Choose analog output level |
0x332D001E | mmi_str_anal_choice | 4 mA;20 mA;Other;End |
0x332D001F | mmi_str_out_level | Output value: |
0x332D0021 | mmi_str_ao1_fixed | Analog Output 1 is fixed at %0 |
0x332D0023 | mmi_str_conn_ref | Connect reference meter |
0x332D0026 | mmi_str_ao1_to_n | About to set analog output 1 to %0 mA |
0x332D0028 | mmi_str_enter_val | Enter meter value |
0x332D0029 | mmi_str_at_4ma | Is fld dev 4.00 mA output equal to reference meter? |
0x332D002A | mmi_str_at_20ma | Is fld dev 20.00 mA output equal to reference meter? |
0x332D002B | mmi_str_yes_no | Yes;No |
0x332D002C | mmi_str_selftest_comp | Selftest complete |
0x332D002D | mmi_str_return_out | Returning fld dev to original output |
0x332D002E | mmi_str_return_auto | NOTE-Loop may be returned to automatic control |
0x332D002F | mmi_str_temp_off_cal_comp | Temperature Offset Calibration Complete |
0x332D0030 | mmi_str_temp_slop_cal_comp | Temperature Slope Calibration Complete |
0x332D0031 | mmi_str_xmtr_stat_comp | Transmitter status complete |
0x332D0032 | mmi_str_xmtr_stat_ok | Transmitter status OK |
0x332D0033 | mmi_str_unit_msg | NOTE-Variables which use this as the units code will be in the previous units until this value is sent to the device |
0x332D0035 | mmi_str_fo_scaling_msg | NOTE-Send scaling method selection to the device prior to performing frequency output scaling. |
0x332D0036 | mmi_str_fd_cal_minimum | NOTE: Flow rate must be greater than 50% of the nominal flow for the meter. |
0x332D0037 | mmi_str_sens_type_choice | T-Series;Other |
0x332D0038 | mmi_str_sens_type | Sensor type: |
0x332D004A | mmi_str_fault_level_msg | NOTE-When selecting upscale or downscale,configure fault value before sending fault code to the device. |
0x332E0000 | mmi_pv_hot_rerange_label | Anlog 1 range vals |
0x332E0002 | mmi_pv_range_label | Anlog 1 range vals |
0x332E0004 | mmi_freq_rerange_label | Freq scaling |
0x332E0007 | mmi_view_xmtr_vars_label | View fld dev vars |
0x332E0008 | mmi_view_output_vars_label | View output vars |
0x332E0009 | mmi_test_status_menu_label | Test/Status |
0x332E000A | mmi_characterize_info_label | Charize sensor |
0x332E000B | mmi_output_vars_label | Config outputs |
0x332E000C | mmi_event_info_label | Config events |
0x332E000D | mmi_view_pv_label | View PV-Analog 1 |
0x332E000F | mmi_view_qv_label | View QV |
0x332E0010 | mmi_view_ev1_label | View event 1 |
0x332E0011 | mmi_view_ev2_label | View event 2 |
0x332E0012 | mmi_config_auto_zero_label | Auto zero |
0x332E0013 | mmi_dens_trim_label | Density cal |
0x332E0015 | mmi_density_char_label | Density |
0x332E0016 | mmi_flow_vars_label | Flow |
0x332E0017 | mmi_dens_vars_label | Density |
0x332E0018 | mmi_temp_vars_label | Temperature |
0x332E001D | mmi_config_event1_label | Event 1 |
0x332E001E | mmi_config_event2_label | Event 2 |
0x332E001F | mmi_config_spec_mass_units_label | Spcl mass units |
0x332E0020 | mmi_config_spec_vol_units_label | Spcl vol units |
0x332E0021 | mmi_review_device_info_label | Device info |
0x332E0022 | mmi_review_calibration_info_label | Charize sensor |
0x332E0023 | mmi_review_xmtr_info_label | Fld dev vars |
0x332E0024 | mmi_review_output_info_label | Outputs |
0x332E0025 | mmi_upload_variables_label | Write variables |
0x332E0026 | mmi_dencal_a_label | Dens Pt1 (Air) |
0x332E0027 | mmi_dencal_b_label | Dens Pt2 (Water) |
0x332E0028 | mmi_characterize_ext_input_label | Polling Setup |
0x332E002B | mmi_rs485_config_label | RS485 Setup |
0x332E002D | mmi_update_rate_label | Update Rate |
0x332E002F | mmi_reset_all_total_label | Reset all totals |
0x332E0030 | mmi_reset_mass_total_label | Reset mass total |
0x332E0031 | mmi_reset_vol_total_label | Reset volume total |
0x332E0032 | mmi_view_sv_label | View SV |
0x332E0033 | mmi_fo_ranging_label | FO Scaling |
0x332E0035 | mmi_d1_label | D1 |
0x332E0036 | mmi_d2_label | D2 |
0x332E0037 | mmi_dencal_fd_label | Flowing Dens (FD) |
0x332E0038 | mmi_pres_vars_label | Pressure |
0x332E0039 | mmi_d3_label | D3 |
0x332E003A | mmi_d4_label | D4 |
0x332E003B | mmi_k3_label | K3 |
0x332E003C | mmi_k4_label | K4 |
0x332E003D | mmi_dencal_c_label | Dens Pt3 T-series |
0x332E003E | mmi_dencal_d_label | Dens Pt4 T-series |
0x332E003F | mmi_output_opt_brd_label | Output Opt. Brd. |
0x332E0040 | mmi_sens_type_code_label | Sensor Type |
0x332E0041 | mmi_flow_char_label | Flow |
0x332E0042 | mmi_sens_setup_meth_label | Sensor Selection |
0x332E0043 | mmi_lmv_fault_timeout_label | Fault Timeout |
0x332E004D | mmi_ao_setup_label | AO Setup |
0x332E004E | mmi_fo_setup_label | FO Setup |
0x332E0089 | mmi_trim_outputs_menu_label | Trim Outputs |
0x332E008A | mmi_read_outputs_menu_label | Read Outputs |
0x332E008D | mmi_view_tv_fo_label | View TV-Freq |
0x332F0000 | mmi_no_label | No |
0x332F0001 | mmi_temp_ovrrng_label | Temperature out of range |
0x332F0002 | mmi_ev1_triggered_label | Event 1 triggered |
0x332F0003 | mmi_ev2_triggered_label | Event 2 triggered |
0x332F000B | mmi_data_loss_label | Data loss possible |
0x332F000C | mmi_meter_factors_label | Meter factors |
0x332F000D | mmi_tube_diag_label | Test Points |
0x332F000E | mmi_mass_rate_factor_label | Mass factor |
0x332F000F | mmi_vol_rate_factor_label | Vol factor |
0x332F0010 | mmi_dens_factor_label | Dens factor |
0x332F0011 | mmi_tube_freq_label | Tube |
0x332F0012 | mmi_tube_amplitude_L_label | LPO |
0x332F0013 | mmi_tube_amplitude_R_label | RPO |
0x332F0014 | mmi_drive_gain_label | Drive |
0x332F0015 | mmi_live_zero_label | Live zero flow |
0x332F0017 | mmi_fd_label | FD |
0x332F001A | mmi_halar_label | Halar |
0x332F001B | mmi_disabled_label | Disabled |
0x332F001C | mmi_enabled_label | Enabled |
0x332F001D | mmi_modbus_rtu_label | Modbus RTU |
0x332F001E | mmi_modbus_ascii_label | Modbus ASCII |
0x332F001F | mmi_b_1200_label | 1200 |
0x332F0020 | mmi_b_2400_label | 2400 |
0x332F0021 | mmi_b_4800_label | 4800 |
0x332F0022 | mmi_b_9600_label | 9600 |
0x332F0023 | mmi_b_19200_label | 19200 |
0x332F0024 | mmi_b_38400_label | 38400 |
0x332F0025 | mmi_odd_label | Odd |
0x332F0026 | mmi_even_label | Even |
0x332F002B | mmi_output_type_label | Output Type |
0x332F002C | mmi_high_alarm_label | High Alarm |
0x332F0031 | mmi_internal_zero_all_to_0_label | IntZero-All 0 |
0x332F0033 | mmi_internal_zero_flow_0_label | IntZero-Flow 0 |
0x332F0034 | mmi_NAN_label | Not-a-Number |
0x332F0035 | mmi_analog_io_brd_label | Analog I/O |
0x332F0036 | mmi_fieldbus_brd_label | Fieldbus (H1) |
0x332F0037 | mmi_sens_type_other_label | Other |
0x332F0038 | mmi_sens_type_tseries_label | T-Series |
0x332F0039 | mmi_pv | PV |
0x332F003A | mmi_mass_flow_digital_value | Mass flo |
0x332F003B | mmi_temperature_digital_value | Temp |
0x332F003C | mmi_density_digital_value | Dens |
0x332F003D | mmi_volume_flow_digital_value | Vol flo |
0x332F003E | mmi_SGU | SGU |
0x332F003F | mmi_burst_mode_enabled | Burst mode enabled |
0x332F0040 | mmi_tag | Tag |
0x332F0041 | mmi_units | Unit |
0x332F0042 | mmi_configure_xmtr_vars | Config fld dev vars |
0x332F0043 | mmi_fix_frequency_output | Fix Frequency Out |
0x332F0044 | mmi_perform_auto_zero | Perform auto zero |
0x332F0045 | mmi_primary_variable_is | PV is |
0x332F0046 | mmi_secondary_variable_is | SV is |
0x332F0047 | mmi_tertiary_variable_is | TV is |
0x332F0048 | mmi_upscale | Upscale |
0x332F0049 | mmi_downscale | Downscale |
0x332F004A | mmi_off | Off |
0x332F004B | mmi_on | On |
0x332F004D | mmi_20hz | Normal |
0x332F004E | mmi_100hz | Special |
0x332F004F | mmi_dens_pres_factor_unit_label | g/Cucm per psi |
0x332F0050 | mmi_flow_pres_factor_unit_label | % per psi |
0x332F005E | mmi_ext_temperature_digital_value | External Temperature |
0x332F0061 | mmi_density_cutoff | Dens Cutoff |
0x332F0082 | mmi_reset_mass_total_only_label | Reset Mass Total |
0x332F0083 | mmi_reset_vol_total_only_label | Reset Vol Total |
0x332F0089 | mmi_ext_pressure | External Pres |
0x332F008C | mmi_mass_flow_1500 | 1500 Mass flo |
0x33300000 | mmi_dens_temp_grad_oor_label | Density Temp. Gradient out-of-range |
0x33300001 | mmi_dens_freq_const1_oor_label | Density Frequency Constant 1 out-of-range |
0x33300002 | mmi_dens_freq_const2_oor_label | Density Frequency Constant 2 out-of-range |
0x33300003 | mmi_flow_temp_const_oor_label | Flow Temperature Constant out-of-range |
0x33300004 | mmi_flow_freq_const_oor_label | Flow Frequency Constant out-of-range |
0x33300005 | mmi_invalid_cutoff_type_code_label | Invalid Cutoff Type Code |
0x33300008 | mmi_invalid_output_number_code | Invalid Output Code |
0x33300009 | mmi_zero_pres_corr_resp_label | Zero Pres. Correction Pt. too low |
0x33300010 | mmi_invalid_sensor_type_code_label | Invalid sensor type code |
0x33300015 | mmi_spcl_mass_conv_oor | Special units mass conversion number out of range |
0x33300016 | mmi_frequency_oor | Frequency out of range |
0x33300017 | mmi_flow_rate_factor_oor | Flow rate factor out of range |
0x33300018 | mmi_pulses_per_unit_oor | Pulses/Unit out of range |
0x33300019 | mmi_units_per_pulse_oor | Units/Pulse out of range |
0x3330001A | mmi_spcl_vol_conv_oor | Special units volume conversion number out of range |
0x3330001B | mmi_density_high_limit_oor | Density high limit out of range |
0x3330001C | mmi_density_low_limit_oor | Density low limit out of range |
0x3330001D | mmi_slug_duration_oor | Slug duration out of range |
0x3330001E | mmi_maximum_zeroing_time_oor | Maximum zeroing time out of range |
0x3330001F | mmi_maximum_pulse_width_oor | Maximum pulse width out of range |
0x33300020 | mmi_analog_fault_level_oor | Analog fault level out of range |
0x33300021 | mmi_fault_timeout_oor | Fault timeout out of range |
0x33300022 | mmi_dens_for_cal_oor | Density for calibration out of range |
0x33300023 | mmi_fdcalval_oor | FD correction factor out of range |
0x33300024 | mmi_d3_oor | D3 out of range |
0x33300025 | mmi_d4_oor | D4 out of range |
0x33300026 | mmi_k3_oor | K3 out of range |
0x33300027 | mmi_k4_oor | K4 out of range |
0x33300028 | mmi_low_cutoff_oor | Low flow cutoff out of range |
0x33300029 | mmi_d1_oor | D1 out of range |
0x3330002A | mmi_d2_oor | D2 out of range |
0x3330002B | mmi_k1_oor | K1 out of range |
0x3330002C | mmi_k2_oor | K2 out of range |
0x3330002D | mmi_temp_comp_oor | Temp correction factor out of range |
0x3330002E | mmi_sp_oor | Setpoint out of range |
0x3330002F | mmi_mass_fact_oor | Mass rate flow factor out of range |
0x33300030 | mmi_dens_fact_oor | Density factor out of range |
0x33300031 | mmi_vol_fact_oor | Volume rate flow factor out of range |
0x33300033 | mmi_invalid_update_rate | Invalid update rate |
0x33300037 | mmi_dens_pres_corr_resp_label | Density pressure correction value out-of-range |
0x33300038 | mmi_flow_pres_corr_resp_label | Flow pressure correction value out-of-range |
0x3330003E | mmi_fo_mode_oor | Mode out of range |
0x3330003F | mmi_fo_disabled_oor | FO Disabled |
0x33300049 | mmi_polarity_oor | Invalid Polarity |
0x3330004A | mmi_density_cutoff_oor | Density cutoff out of range |
0x3330004B | mmi_density_units_oor | Invalid density cutoff units |
0x3330004C | mmi_invalid_option_label | Invalid Option |
0x3330004D | mmi_static_pres_resp_label | Static Pressure value out-of-range |
0x3330004E | mmi_static_temp_resp_label | Static Temperature value out-of-range |
0x33310000 | mmi_eeprom_chksum_error_700 | EEPROM Checksum - Core processor |
0x33310001 | mmi_ram_test_error_700 | RAM Error - Core Processor |
0x33310004 | mmi_fo_fixed_label | Freq. Output Fixed |
0x33310005 | mmi_line_rtd_oor_label | Line RTD Overrange |
0x33310006 | mmi_case_rtd_oor_label | Meter RTD Overrange |
0x33310008 | mmi_sensor_type_charize | Unrecognized/Unentered Sensor Type (K1) |
0x33310009 | mmi_flocal_charize | Calibration Factor Unentered (Flocal) |
0x3331000A | mmi_temp_slopecal_label | Temp. Slope Cal in Progress |
0x3331000B | mmi_temp_zerocal_label | Temp. Zero Cal in Progress |
0x3331000C | mmi_dens_fdcal_label | Density FD Cal in Progress |
0x3331000D | mmi_dens_d2cal_label | Density 2nd Point Cal in Progress |
0x3331000E | mmi_dens_d1cal_label | Density 1st Point Cal in Progress |
0x3331000F | mmi_mech_zerocal_label | Mech. Zero Cal in Progress |
0x33310010 | mmi_dens_d3cal_label | Density 3rd Point Cal in Progress |
0x33310011 | mmi_dens_d4cal_label | Density 4th Point Cal in Progress |
0x33310012 | mmi_eeprom_cfg_error_700 | EEPROM Config. Corrupt - Core Processor |
0x33310013 | mmi_eeprom_tot_error_700 | EEPROM Totals Corrupt - Core Processor |
0x33310014 | mmi_eeprom_prg_error_700 | EEPROM Program Corrupt - Core Processor |
0x33310016 | mmi_xmtr_comm_err_label | Sensor/Xmtr Communication Error |
0x33310017 | mmi_boot_sector_error_label | Core Processor Boot Sector Fault |
0x33310019 | mmi_flow_dir_status_label | Flow is in reverse direction |
0x3331001C | mmi_ext_error_label | External Input Error |
0x33310021 | mmi_security_breach | Security Breach |
0x33310022 | mmi_eeprom_chksum_error_3000 | EEPROM Checksum - 3000 |
0x33310023 | mmi_ram_test_error_3000 | RAM Error - 3000 |
0x33310024 | mmi_sw_upgrade_3000_label | Series 3000 software upgrade recommended |
0x33310031 | mmi_A28_comm_err_label | Unrecognized parameter to core processor |
0x33320000 | mmi_mass_flow_digital_cutoff_help_index | The mass flow rate below which the frequency/pulse output indicates zero flow,and below which totalizers stop counting. |
0x33320001 | mmi_alarm_select_help_index | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. |
0x33320002 | mmi_hzfreq_help_index | The number of cycles,in Hertz,that equal a proportional flow rate represented by the frequency/pulse output. |
0x33320003 | mmi_hzrate_help_index | The flow rate that equals a set frequency if the frequency output represents mass or volume flow ; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. |
0x33320004 | mmi_vol_flow_digital_cutoff_help_index | The volume flow rate below which the frequency/pulse output indicates zero flow,and below which totalizers stop counting. |
0x33320005 | mmi_flange_type_help_index | Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. |
0x33320006 | mmi_liner_matl_help_index | Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. |
0x33320007 | mmi_sensor_model_help_index | Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. |
0x33320008 | mmi_sensor_matl_help_index | Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. |
0x33320009 | mmi_sp_mass_help_index | A standard engineering unit that serves as the mass component in a special unit. |
0x3332000A | mmi_sp_mass_time_help_index | A standard unit of time (seconds,minutes,hours,or days) that serves as the time component in a special unit. |
0x3332000B | mmi_sp_mass_fact_help_index | A programmable multiplier for the base mass unit in a special unit. |
0x3332000C | mmi_sp_mass_rate_text_help_index | A 1 to 8 character description of a special unit of flow. |
0x3332000D | mmi_sp_mass_total_text_help_index | A 1 to 8 character description of a special unit of mass,which is based on the special unit of flow to represent total. |
0x3332000E | mmi_slughi_help_index | A programmable high limit on density,which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
0x3332000F | mmi_sluglo_help_index | A programmable low limit on density,which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
0x33320010 | mmi_flocal_help_index | A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. |
0x33320011 | mmi_ma_cutoff_help_index | The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. |
0x33320012 | mmi_sp_volume_help_index | A standard engineering unit that serves as the volume component in a special unit. |
0x33320013 | mmi_sp_volume_time_help_index | A standard unit of time (seconds,minutes,hours,or days) that serves as the time component in a special unit. |
0x33320014 | mmi_sp_volume_fact_help_index | A programmable multiplier for the base volume unit in a special unit. |
0x33320015 | mmi_sp_volume_rate_text_help_index | A 1 to 8 character description of a special unit of flow. |
0x33320016 | mmi_sp_volume_total_text_help_index | A 1 to 8 character description of a special unit of volume,which is based on the special unit of flow to represent total. |
0x33320017 | mmi_fixfreq_help_index | A value (in Hertz) that will be indicated on the frequency output for the purpose of a loop test. |
0x33320018 | mmi_max_zero_help_index | The number of readings collected from the sensor during an Auto Zero operation. |
0x33320019 | mmi_pulse_width_help_index | A programmable time period,in seconds,that defines the crossover frequency for the frequency output,where Crossover freq. = 1 / (2 x Pulse width) . Below the crossover,the output has a constant ON state,and an OFF state that varies with frequency. |
0x3332001A | mmi_tempcal_help_index | A 14-character factor that describes the slope and offset of the linear output representing flow tube temperature. |
0x3332001B | mmi_rt_zero_help_index | A value,in microseconds,representing the phase shift between velocity signals from the sensor when measuring zero flow. |
0x3332001C | mmi_rt_sigma_help_index | A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. |
0x3332001D | mmi_timeout_help_index | A programmable time period,from 0.00 to 60.00 seconds,during which outputs representing flow hold their last measured value before indicating slug flow. |
0x33320020 | mmi_D1_help_index | The density,in g/cc,of the air or other low-density fluid used during a 2-point density calibration. |
0x33320021 | mmi_D2_help_index | The density,in g/cc,of the water or other high-density fluid used during a 2-point density calibration. |
0x33320022 | mmi_K1_help_index | The tube period,in microseconds,corresponding to a density equal to D1. |
0x33320023 | mmi_K2_help_index | The tube period,in microseconds,corresponding to a density equal to D2. |
0x33320024 | mmi_DCoef_help_index | The percent change in the elasticity of the flow tubes around the bending axis per 100 degrees Celsius. |
0x33320025 | mmi_alarm_type_help_index | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. |
0x33320026 | mmi_rt_freq_help_index | The frequency,in Hertz,presently being indicated on the frequency output. |
0x33320027 | mmi_zero_offset_units_help_index | Units for zero offset - always microseconds. |
0x33320028 | mmi_date_help | Date- Gregorian calendar date,entered as mm/dd/yy,that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. |
0x33320029 | mmi_temp_for_cal_help_index | User-entered temperature for the purpose of performing an on-line temperature calibration. |
0x3332002A | mmi_auto_zero_help_index | Please refer to manual for complete calibration instructions. |
0x3332002B | mmi_density_cal_help_index | Please refer to manual for complete calibration instructions. |
0x3332002C | mmi_fix_frequency_output_help_index | Outputs a user-programmed frequency to the frequency output. |
0x3332002D | mmi_self_test_help_index | Instructs transmitter to perform internal self test. |
0x3332002E | mmi_totctl_help_index | Allows the user to Reset,Stop,or Start all totalizers. NOTE - Inventory totals are NOT reset. |
0x3332002F | mmi_abort_auto_zero_help_index | Aborts Auto Zero operation and continues to use previous zero offset value. |
0x33320030 | mmi_leave_fixed_freq_mode_help_index | Exits fixed mode and returns the frequency output to its active state. |
0x33320031 | mmi_Event_1_Status_help_index | When set,indicates that Event 1 has reached its programmed setpoint. |
0x33320032 | mmi_Event_2_Status_help_index | When set,indicates that Event 2 has reached its programmed setpoint. |
0x33320033 | mmi_report_xmtr_status_help_index | Reports any currently active device status information. |
0x33320034 | mmi_total_start_help_index | Enables the internal totalizers to begin counting. |
0x33320035 | mmi_total_stop_help_index | Prevents the internal totalizers from counting. |
0x33320036 | mmi_total_reset_help_index | Resets internal totalizers. |
0x33320037 | mmi_temp_calibration_help_index | Please refer to manual for complete calibration instructions. |
0x33320038 | mmi_tube_freq_help_index | The tube frequency of the sensor measured in Hertz. |
0x33320039 | mmi_tube_amplitude_help_index | The pickoff voltage of the sensor measured in Voltage. |
0x3332003A | mmi_drive_gain_help_index | The drive gain of the transmitter. |
0x3332003B | mmi_live_zero_help_index | This flow value is not effected by the flow cutoff and is damped at 8 seconds. It is to be used for diagnostic purposes only and is not used in ANY flow calculations or totalization. |
0x3332003D | mmi_fd_help_index | A calibration constant generated during a flowing density calibration. |
0x3332003E | mmi_pulses_unit_help_index | This parameter allows you to scale the frequency output in terms of the number of pulses per unit of flow. |
0x3332003F | mmi_units_pulse_help_index | This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. |
0x33320041 | mmi_fo_scaling_help_index | This parameter allows you to scale the frequency output by using freq=flow,pulses/unit,or units/pulse. This parameter must be sent to the device before you make scaling changes. |
0x33320042 | mmi_dens_tgco_help_index | This parameter represents the Density Temperature Gradient Coefficient (DTG) that is on the T-series sensor tag. |
0x33320043 | mmi_dens_fqco1_help_index | This parameter represents the Density Frequency Coefficient #1 (DFQ1) that is on the T-series sensor tag. |
0x33320044 | mmi_dens_fqco2_help_index | This parameter represents the Density Frequency Coefficient #2 (DFQ2) that is on the T-series sensor tag. |
0x33320045 | mmi_flow_tgco_help_index | This parameter represents the Flow Temperature Gradient Coefficient (FTG) that is on the T-series sensor tag. |
0x33320046 | mmi_flow_fqco_help_index | This parameter represents the Flow Frequency Coefficient (FFQ) that is on the T-series sensor tag. |
0x33320047 | mmi_ma_fault_level_help_index | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 1.0 to 3.6 mA for downscale or 21.0 to 24.0 for upscale. |
0x33320051 | mmi_rs485_protocol_help_index | This parameter defines the protocol that will be used on the RS485 physical layer. |
0x33320052 | mmi_rs485_baudrate_help_index | This parameter defines the baud rate for the protocol that will be used on the RS485 physical layer. |
0x33320053 | mmi_rs485_parity_help_index | This parameter defines the parity for the protocol that will be used on the RS485 physical layer. |
0x33320054 | mmi_rs485_stop_help_index | This parameter defines the number of stop bits for the protocol that will be used on the RS485 physical layer. |
0x33320056 | mmi_met_direct_help_index | This paramater enables the user to determine whether the outputs and totalizers will indicate forward,reverse,bi-directional or absolute value flow. |
0x33320057 | mmi_fault_code_help_index | Downscale: Milliamp outputs that indicate flow go to the configured limit,the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. |
0x33320058 | mmi_mass_rate_factor_help_index | A value,between 0.8 and 1.2,that will act as a multiplier for the mass flow rate. |
0x33320059 | mmi_vol_rate_factor_help_index | A value,between 0.8 and 1.2,that will act as a multiplier for the volume flow rate. |
0x3332005A | mmi_dens_factor_help_index | A value,between 0.8 and 1.2,that will act as a multiplier for the density. |
0x3332005B | mmi_fo_fault_level_help_index | This parameter allows you to select the upper frequency output level that will indicate a fault condition. The maximum value is 15000 Hz. |
0x3332005D | mmi_update_rate_help_index | This parameter is the update rate for process variables through the system. Set the update rate to NORMAL for most applications. Set the update rate to SPECIAL if you are using the device in proving applications or extremely short batch applications. Refer to the user's manual for more information before you change this parameter. |
0x3332005E | mmi_dig_fault_code_help_index | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) |
0x3332005F | mmi_d3_help_index | The density,in g/cc,of the water or other high-density fluid that is used during a 4-point density calibration with Micro Motion T-series sensors. D3 can represent the D3 value for a Micro Motion T-series sensor. |
0x33320060 | mmi_d4_help_index | The density,in g/cc,of the water or other high-density fluid that is used during a 4-point density calibration with Micro Motion T-series sensors. D4 can represent the D4 value for a Micro Motion T-series sensor. |
0x33320061 | mmi_K3_help_index | The tube period,in microseconds,corresponding to a density equal to D3. |
0x33320062 | mmi_K4_help_index | The tube period,in microseconds,corresponding to a density equal to D4. |
0x33320063 | mmi_poll_ctrl_help_index | A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. |
0x33320064 | mmi_sens_type_code_help | This paramater indicates which type of sensor is being used for process measurement. |
0x33320065 | mmi_output_opt_brd_help | This parameter represents the various types of output option boards that are available. |
0x33320066 | mmi_sens_setup_meth_help | This selection must be made to enable calibration parameters to be visible for the selected sensor type. |
0x33320067 | mmi_alarm_setpoint_help_index | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. |
0x33320068 | mmi_alarm_varcode_help_index | Assigns a process variable to event 1 or event 2. |
0x33320069 | mmi_board_temp_help_index | The board temperature of the core processor. |
0x3332006A | mmi_case_temp_help_index | The meter temperature of the T-Series sensor. |
0x3332006C | mmi_lmv_fault_timeout_help | This parameter defines the number of seconds for which all outputs will hold their last measured value prior to going to the configured fault state. The default is zero seconds. |
0x3332006D | mmi_digital_units_help | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation,Minimum Span,Upper Range Value,Lower Range Value,Lower Sensor Limit,and Upper Sensor Limit. |
0x3332006E | mmi_dp_tag_help_index | This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). |
0x3332006F | mmi_poll_var_help_index | This represents the variable code which will be read via HART for the compensation. |
0x33320070 | mmi_poll_type_help_index | This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. |
0x33320071 | mmi_update_rate_var_help_index | This parameter identifies the transmitter variable that will be updated at 100 Hz. All others will be updated,but at a slower rate. |
0x33320075 | mmi_flow_pres_factor_help_index | Pressure compensation factor applied to flow rate (% change per PSI) . |
0x33320076 | mmi_dens_pres_factor_help_index | Pressure compensation factor applied to density (g/Cucm change per PSI) . |
0x33320077 | mmi_zero_pres_factor_help_index | Pressure at which flow calibration was performed. |
0x33320080 | mmi_fo_mode_help_index | This parameter allows you to set the mode of the second frequency output when dual frequency outputs are configured. |
0x3332008A | mmi_dens_digital_cutoff_help_index | The density below which the density indicates zero. |
0x3332008B | mmi_fo_polarity_help_index | This parameter allows you to set the polarity of the frequency output. |
0x3332008C | mmi_enable_pres_comp_help_index | This parameter allows you to enable/disable the pressure correction feature |
0x3332008D | mmi_static_pressure_help_index | This parameter allows you to enter a static pressure when using the pressure correction feature |
0x3332008F | mmi_enable_extern_temp_help_index | This parameter allows you to enable/disable the external temperature feature |
0x33320090 | mmi_static_temperature_help_index | This parameter allows you to enter a static temperature when using the external temperature feature |
0x333200C1 | mmi_modbus_address_help_index | This parameter defines the Modbus slave address. Addresses 1-15,32-47,64-79,or 96-110 are allowed |
Reference ID | Label | String |