0 |
M3500 |
1 |
Meriam Pressure Transmitter |
2 |
EPI comm fail |
3 |
CV low |
4 |
reserved |
5 |
M3500 Status |
6 |
Good |
7 |
|
8 |
EPI busy |
9 |
Msg CRC bad |
10 |
Msg timeout |
11 |
Cmd 1 invalid |
12 |
Cmd 2 invalid |
13 |
Cmd 3 invalid |
14 |
Cmd 1 wrong mode |
15 |
Cmd 2 wrong mode |
16 |
Cmd 3 wrong mode |
17 |
Self Test failed |
18 |
Memory error |
19 |
EPI Gen Status |
20 |
EU invalid |
21 |
Location invalid |
22 |
Sensor bad |
23 |
Get/Set failed |
24 |
Soft over range |
25 |
Hard over range |
26 |
EPI Meas Status |
27 |
EPI Units Status |
28 |
EPI Info Status |
29 |
Field Recal not allowed |
30 |
Too far from zero to zero |
31 |
Recal point outside valid range |
32 |
Recal point error beyond limit |
33 |
General recal script error |
34 |
General recal point library error |
35 |
Recal command out of sequence |
36 |
EPI Recal Status |
37 |
PV |
38 |
Primary Variable |
39 |
10.5f |
40 |
Meas Press |
41 |
Pressure measurement used for determining the PV value. |
42 |
Sensor Press Units |
43 |
Sensor pressure units |
44 |
PV Damp |
45 |
Damping Value |
46 |
PV URV |
47 |
PV Upper Range Value |
48 |
PV LRV |
49 |
PV Lower Range Value |
50 |
Sensor Hi Lim |
51 |
Sensor High Limit |
52 |
Sensor Lo Lim |
53 |
Sensor Low Limit |
54 |
PV Min Span |
55 |
PV Mininum Span |
56 |
PV Xfr |
57 |
PV Transfer |
58 |
linear |
59 |
not used, but reported as linear |
60 |
7d |
61 |
3.2f |
62 |
4.2f |
63 |
Meas Type |
64 |
Measurement Type - Pressure, Level or Flow |
65 |
Pressure |
66 |
Level |
67 |
Flow |
68 |
Meas Units |
69 |
Measurement Units |
70 |
cmH2O @20DegC |
71 |
centimeters water at 20 degrees C |
72 |
cmH2O @4DegC |
73 |
centimeters water at 4 degrees C |
74 |
ftH2O @4DegC |
75 |
feet water at 4 degrees C |
76 |
ftH2O @60DegF |
77 |
feet water at 60 degrees F |
78 |
oz/sq in |
79 |
ounces per square inch |
80 |
yard |
81 |
3 feet or 36 inches |
82 |
L/d |
83 |
Liters per day |
84 |
CuYd/s |
85 |
Cubic yards per second |
86 |
CuYd/min |
87 |
Cubic yards per minute |
88 |
CuYd/hr |
89 |
Cubic yards per hour |
90 |
CuYd/d |
91 |
Cubic yards per day |
92 |
CuIn/s |
93 |
Cubic inch per second |
94 |
CuIn/min |
95 |
Cubic inch per minute |
96 |
CuIn/hr |
97 |
Cubic inch per hour |
98 |
CuIn/d |
99 |
Cubic inch per day |
100 |
STon/s |
101 |
Short tons per second |
102 |
g/d |
103 |
Grams per day |
104 |
LTon/s |
105 |
Long tons per second |
106 |
LTon/min |
107 |
Long tons per minute |
108 |
MetTon/s |
109 |
Metric ton per second |
110 |
Pressure Units |
111 |
PV Pressure Units |
112 |
Lvl Meas Type |
113 |
Level Measurement Type - Height, Volume, or Mass |
114 |
Height |
115 |
Volume |
116 |
Mass |
117 |
Level Units |
118 |
User defined units |
119 |
Dead Leg |
120 |
Dead Leg Correction Factor |
121 |
Full Tank Hydrostatic |
122 |
The Amount of Hydrostatic Pressure of a Full Tank |
123 |
Mass Units |
124 |
Flow Meas Type |
125 |
Flow Measurement Type - Volume or Mass |
126 |
Flow Calc Type |
127 |
Flow Calculation Type - Square Root or Laminar |
128 |
Sq. Rt. |
129 |
Square Root Flow Calculation |
130 |
Laminar |
131 |
Laminar Flow Calculation |
132 |
Low Flow Cutoff |
133 |
Low Flow Cutoff Value |
134 |
B Coeff Mantissa |
135 |
B Coefficient Mantissa for Laminar Flow Calculation |
136 |
5.5f |
137 |
C Coeff Mantissa |
138 |
C Coefficient Mantissa for Laminar Flow Calculation |
139 |
B Coeff Exponent |
140 |
B Coefficiecnt Exponent for Laminar Flow Calculation |
141 |
E-9 |
142 |
10 to the power -9 |
143 |
E-8 |
144 |
10 to the power -8 |
145 |
E-7 |
146 |
10 to the power -7 |
147 |
E-6 |
148 |
10 to the power -6 |
149 |
E-5 |
150 |
10 to the power -5 |
151 |
E-4 |
152 |
10 to the power -4 |
153 |
E-3 |
154 |
10 to the power -3 |
155 |
E-2 |
156 |
10 to the power -2 |
157 |
E-1 |
158 |
10 to the power -1 |
159 |
E 0 |
160 |
10 to the power 0 |
161 |
E+1 |
162 |
10 to the power +1 |
163 |
E+2 |
164 |
10 to the power +2 |
165 |
E+3 |
166 |
10 to the power +3 |
167 |
E+4 |
168 |
10 to the power +4 |
169 |
E+5 |
170 |
10 to the power +5 |
171 |
E+6 |
172 |
10 to the power +6 |
173 |
E+7 |
174 |
10 to the power +7 |
175 |
E+8 |
176 |
10 to the power +8 |
177 |
E+9 |
178 |
10 to the power +9 |
179 |
C Coeff Exponent |
180 |
C Coefficiecnt Exponent for Laminar Flow Calculation |
181 |
Volume Units |
182 |
Time Units |
183 |
per min |
184 |
per sec |
185 |
per hr |
186 |
per day |
187 |
Flow Scaling Factor |
188 |
.7f |
189 |
Tank Type |
190 |
Tank Type - Linear (vertical), non-linear (spherical or horizontal cylinder), or Custom Strapping |
191 |
Linear |
192 |
Linear Tank |
193 |
Non-Linear |
194 |
Non-linear Tank |
195 |
Custom |
196 |
Custom Strapping Table Tank |
197 |
Tank Cyl Cap |
198 |
Capacity in EU of cylindrical portion of tank |
199 |
.4f |
200 |
Tank Ends Cap |
201 |
Capacity in EU of tank ends |
202 |
TableIndex |
203 |
Position in the Strapping Table - (1 to 21) |
204 |
2d |
205 |
Level % 01 |
206 |
Custom Strapping - Level Value 01 |
207 |
% |
208 |
Volume 01 |
209 |
Custom Strapping - Volume Value 01 |
210 |
Level % 02 |
211 |
Custom Strapping - Level Value 02 |
212 |
Volume 02 |
213 |
Custom Strapping - Volume Value 02 |
214 |
Level % 03 |
215 |
Custom Strapping - Level Value 03 |
216 |
Volume 03 |
217 |
Custom Strapping - Volume Value 03 |
218 |
Level % 04 |
219 |
Custom Strapping - Level Value 04 |
220 |
Volume 04 |
221 |
Custom Strapping - Volume Value 04 |
222 |
Level % 05 |
223 |
Custom Strapping - Level Value 05 |
224 |
Volume 05 |
225 |
Custom Strapping - Volume Value 05 |
226 |
Level % 06 |
227 |
Custom Strapping - Level Value 06 |
228 |
Volume 06 |
229 |
Custom Strapping - Volume Value 06 |
230 |
Level % 07 |
231 |
Custom Strapping - Level Value 07 |
232 |
Volume 07 |
233 |
Custom Strapping - Volume Value 07 |
234 |
Level % 08 |
235 |
Custom Strapping - Level Value 08 |
236 |
Volume 08 |
237 |
Custom Strapping - Volume Value 08 |
238 |
Level % 09 |
239 |
Custom Strapping - Level Value 09 |
240 |
Volume 09 |
241 |
Custom Strapping - Volume Value 09 |
242 |
Level % 10 |
243 |
Custom Strapping - Level Value 10 |
244 |
Volume 10 |
245 |
Custom Strapping - Volume Value 10 |
246 |
Level % 11 |
247 |
Custom Strapping - Level Value 11 |
248 |
Volume 11 |
249 |
Custom Strapping - Volume Value 11 |
250 |
Level % 12 |
251 |
Custom Strapping - Level Value 12 |
252 |
Volume 12 |
253 |
Custom Strapping - Volume Value 12 |
254 |
Level % 13 |
255 |
Custom Strapping - Level Value 13 |
256 |
Volume 13 |
257 |
Custom Strapping - Volume Value 13 |
258 |
Level % 14 |
259 |
Custom Strapping - Level Value 14 |
260 |
Volume 14 |
261 |
Custom Strapping - Volume Value 14 |
262 |
Level % 15 |
263 |
Custom Strapping - Level Value 15 |
264 |
Volume 15 |
265 |
Custom Strapping - Volume Value 15 |
266 |
Level % 16 |
267 |
Custom Strapping - Level Value 16 |
268 |
Volume 16 |
269 |
Custom Strapping - Volume Value 16 |
270 |
Level % 17 |
271 |
Custom Strapping - Level Value 17 |
272 |
Volume 17 |
273 |
Custom Strapping - Volume Value 17 |
274 |
Level % 18 |
275 |
Custom Strapping - Level Value 18 |
276 |
Volume 18 |
277 |
Custom Strapping - Volume Value 18 |
278 |
Level % 19 |
279 |
Custom Strapping - Level Value 19 |
280 |
Volume 19 |
281 |
Custom Strapping - Volume Value 19 |
282 |
Level % 20 |
283 |
Custom Strapping - Level Value 20 |
284 |
Volume 20 |
285 |
Custom Strapping - Volume Value 20 |
286 |
User EU Scaling Factor |
287 |
Alarm Hi |
288 |
High measurement value alarm setting |
289 |
Alarm Lo |
290 |
Low measurement value alarm setting |
291 |
Alarm DB |
292 |
Alarm deadband setting |
293 |
AO Fail Mode |
294 |
Fail High |
295 |
AO goes high on device error mode |
296 |
Fail Low |
297 |
AO goes low on device error mode |
298 |
Temperature |
299 |
Electronics temperature measurement |
300 |
4.1f |
301 |
4.0f |
302 |
Temperature Units |
303 |
Total Flow |
304 |
Flow Since Device Activation |
305 |
Resetable Total |
306 |
Flow Since Last Reset |
307 |
Totalizer Units |
308 |
Recal Command |
309 |
Recal State |
310 |
Recal General Status |
311 |
Recal Specific Status |
312 |
Pressure Cal Status |
313 |
CAL Apply Point |
314 |
Calibration pressure value to apply |
315 |
CAL Apply Pt LRV |
316 |
Calibration pressure lower range limit |
317 |
CAL Apply Pt URV |
318 |
Calibration pressure upper range limit |
319 |
Sensor S/N |
320 |
Software Version |
321 |
Max Measurement Range |
322 |
Maximum upper range value for the measurement |
323 |
Min Measurement Range |
324 |
Minimum lower range value for the measurement |
325 |
Min Meas Span |
326 |
Minimum measurement span |
327 |
Process Measurement |
328 |
Measured Pressure |
329 |
Xmtr Vars |
330 |
Diag/Service |
331 |
Calibration |
332 |
Device Status |
333 |
Basic Setup |
334 |
Sensor Info |
335 |
Device Information |
336 |
Alarm Setup |
337 |
Level Config |
338 |
Tank Config |
339 |
Flow Config |
340 |
Detailed Setup |
341 |
Strapping Table |
342 |
Offline Variables |
343 |
Reset To Factory Defaults |
344 |
Reset Flow Totalizer |
345 |
2 Pt Pressure Cal |
346 |
Abort Pressure Cal |
347 |
Temperature Cal |
348 |
FMU860 |
349 |
DT |
350 |
DVC |
351 |
FCX |
352 |
AS800 |
353 |
340T |
354 |
340C |
355 |
344 |
356 |
Siemens Micro K |
357 |
SITRANS L |
358 |
SIPAN PH |
359 |
SITRANS P |
360 |
75SMT |
361 |
UNIDELTA |
362 |
8320 |
363 |
SX5100 |
364 |
TSV175 |
365 |
DMU |
366 |
3780 |
367 |
BM70 |
368 |
8u |
369 |
low |
370 |
high |
371 |
tmp_av |
372 |
Proceed with
Factory Default
settings restoration? |
373 |
WARN -Loop should be
removed from
automatic control |
374 |
A problem was detected |
375 |
Abort;Fix and Retry |
376 |
Device and parameters
being reset |
377 |
Re-reading device variables.
Please wait ... |
378 |
NOTE-Device config
should be checked
before returning loop
to automatic control |
379 |
Grand Total = %{0}
Reset Total = %{1}
Proceed with
Flow Totalizer reset? |
380 |
Flow Totalizer reset in progress |
381 |
Grand Total = %{0}
Reset Total = %{1}
Flow Totalizer reset
complete |
382 |
Proceed with
2 point
pressure calibration? |
383 |
Initializing 2 point calibration function. Please wait ... |
384 |
2 Pt Cal Error
Gen Status: %3
Spec Status: %4
Consult manual
Calibration must abort. |
385 |
Apply low pressure value:
%0%6
Permitted range is
%1 to
%2 |
386 |
Apply high pressure value:
%0%6
Permitted range is
%1 to
%2 |
387 |
2 point calibration complete |
388 |
2 Pt Cal Error
Gen Status:%3
Spec Status:%4
Consult manual
Calibration must abort. |
389 |
Processing ... |
390 |
NOTE-Loop may be
returned to automatic
control |
391 |
Proceed with
temperature calibration? |
392 |
Enter current temperature value:
|
393 |
Temperature Reading:
%{0}
Temperature calibration
complete |
394 |
WARNING
Upper range,
lower range,
and alarm values
must be corrected. |